PeptideScanner
Peptide Scanner does not sell peptides. Independent, not affiliated with any supplier. Disclaimer

SKO Compounds: claims vs COA

The purity SKO Compounds advertises and the vial sizes on its labels, checked against the 27 certificates of analysis it publishes.

No site-wide purity promise found on the website. Vial content is still checked against the label.

certificates read
27
vials outside ±3% of label
15 / 15
beyond ±10% (major)
10
below advertised purity
None

On label, within ±3%Off label, 3 to 10%Major, beyond ±10%How this is checked

SKO Compounds certificates: label against measured content and purity
ProductLabel to measuredPurityMain impurityLabCOA
BPC-157 10mg
10mg → 12.14mg
Overfilled +21.4%
99.224%
0.78% not itemisedfreedom-diagnosticsOpen certificate BPC-157 10mg
GHK-Cu 50mg
50mg → 58.07mg
Overfilled +16.1%
99.509%
0.49% not itemisedfreedom-diagnosticsOpen certificate GHK-Cu 50mg
MOTS-C 10mg
10mg → 13.57mg
Overfilled +35.7%
99.366%
0.63% not itemisedfreedom-diagnosticsOpen certificate MOTS-C 10mg
NAD+ 500mg
500mg → 560.52mg
Overfilled +12.1%
99.909%
0.09% not itemisedfreedom-diagnosticsOpen certificate NAD+ 500mg
Tesamorelin 10mg
10mg → 11.94mg
Overfilled +19.4%
99.132%
0.87% not itemisedfreedom-diagnosticsOpen certificate Tesamorelin 10mg
bpc-157
10mg → 12.14mg
Overfilled +21.4%
99.224%
0.78% not itemisedfreedom-diagnosticsOpen certificate bpc-157
ghk-cu
50mg → 58.07mg
Overfilled +16.1%
99.509%
0.49% not itemisedfreedom-diagnosticsOpen certificate ghk-cu
mots-c
10mg → 13.57mg
Overfilled +35.7%
99.366%
0.63% not itemisedfreedom-diagnosticsOpen certificate mots-c
nad-plus
500mg → 560.52mg
Overfilled +12.1%
99.909%
0.09% not itemisedfreedom-diagnosticsOpen certificate nad-plus
tesamorelin
10mg → 11.94mg
Overfilled +19.4%
99.132%
0.87% not itemisedfreedom-diagnosticsOpen certificate tesamorelin
GLP-3 RT 10mg
10mg → 10.77mg
Over label +7.7%
99.954%
0.05% not itemisedfreedom-diagnosticsOpen certificate GLP-3 RT 10mg
MT-2 10mg
10mg → 10.37mg
Over label +3.7%
99.79%
0.21% not itemisedfreedom-diagnosticsOpen certificate MT-2 10mg
melanotan-ii
10mg → 10.37mg
Over label +3.7%
99.79%
0.21% not itemisedfreedom-diagnosticsOpen certificate melanotan-ii
retatrutide
10mg → 10.77mg
Over label +7.7%
99.954%
0.05% not itemisedfreedom-diagnosticsOpen certificate retatrutide
retatrutide
10mg → 10.77mg
Over label +7.7%
99.954%
0.05% not itemisedfreedom-diagnosticsOpen certificate retatrutide
fd_SKOC2603060064.pdfNot measured
99.893%
0.11% not itemisedfreedom-diagnosticsOpen certificate fd_SKOC2603060064.pdf
BPC-157 10mgNot measured
99.39%
0.61% not itemisedfreedom-diagnosticsOpen certificate BPC-157 10mg
CJC-1295 NO DAC + IpamorelinBlend, per-component content not listed
99.95%
0.05% not itemisedfreedom-diagnosticsOpen certificate CJC-1295 NO DAC + Ipamorelin
GHK-Cu 50mgNot measured
99.78%
0.22% not itemisedfreedom-diagnosticsOpen certificate GHK-Cu 50mg
GLP-2 TRZ 15mgNot measured
99.91%
0.09% not itemisedfreedom-diagnosticsOpen certificate GLP-2 TRZ 15mg
Glow 70mgBlend, per-component content not listed
99.807%
0.19% not itemisedfreedom-diagnosticsOpen certificate Glow 70mg
Glutathione 1200mgNot measured
99.96%
0.04% not itemisedfreedom-diagnosticsOpen certificate Glutathione 1200mg
Ipamorelin 10mgNot measured
99.46%
0.54% not itemisedfreedom-diagnosticsOpen certificate Ipamorelin 10mg
NAD+ 500mgNot measured
99.92%
0.08% not itemisedfreedom-diagnosticsOpen certificate NAD+ 500mg
Selank 10mgNot measured
99.83%
0.17% not itemisedfreedom-diagnosticsOpen certificate Selank 10mg
Tesamorelin 10mgNot measured
99.86%
0.14% not itemisedfreedom-diagnosticsOpen certificate Tesamorelin 10mg
Wolverine 10mgBlend, per-component content not listed
99.134%
0.87% not itemisedfreedom-diagnosticsOpen certificate Wolverine 10mg

How this is checked

Vial content
Measured net peptide content against the size on the label. Within ±3% is on label, 3 to 10% is off label, beyond ±10% is a major deviation (under- or overfilled). When a certificate weighs several vials of the batch, the vial farthest from the label is the one judged, and with several purity results the lowest counts. Blends are only checked when the certificate lists each component.
Purity
HPLC purity on each certificate against the purity the supplier promises site-wide on its own website. Up to 1 point below the claim is amber, more than that is red. Only a direct promise counts (“99%+ purity guaranteed”); explanations of what purity means, one product's figure and page code are not treated as a claim. A certificate that reports only a bound (“>99%”) is judged only when the bound meets the claim, and a specification line is never read as a result.
Whose certificate
A certificate is only read once our client-identity review has looked at it, and one issued to a different company is left out, whether the automatic check or a manual review found it. A certificate issued to the company that runs the supplier's own website counts as the supplier's. A file hosted on another supplier's website is not counted for this one. The same rules decide which certificates appear on supplier and product pages. Only peptide certificates are read: bacteriostatic water, acetic acid and other diluents are left out, and so are product data sheets, which state a specification rather than a batch result.
Main impurity
Shown when the certificate itemises it: a named impurity (TFA, deletion sequence, oxidation…) or the largest secondary peak in the HPLC peak table. Most certificates report only a purity figure, so the rest of the sample is not itemised.
Trust Score
These checks are 10 of the 25 Transparency points: vial content 7 (full credit within ±3%, half up to ±10%, none beyond, over- and underfilled alike), purity 3 (98% is the bar when a supplier advertises no figure). Fewer than 5 readable results gives half credit rather than a guess.
Source and limits
These are the supplier's own published certificates, read automatically from the PDF or image. Janoshik results tables are read twice from the image, cell by cell, and a figure the two readings disagree on is left out rather than guessed. A certificate covers one batch on one date. We have not tested these batches ourselves.

SKO Compounds supplier page and all suppliers on Claims vs COA