PeptideScanner
Peptide Scanner does not sell peptides. Independent, not affiliated with any supplier. Disclaimer

One Day Compounds: claims vs COA

The purity One Day Compounds advertises and the vial sizes on its labels, checked against the 26 certificates of analysis it publishes.

No site-wide purity promise found on the website. Vial content is still checked against the label.

certificates read
26
vials outside ±3% of label
10 / 17
beyond ±10% (major)
0
below advertised purity
None

On label, within ±3%Off label, 3 to 10%Major, beyond ±10%How this is checked

One Day Compounds certificates: label against measured content and purity
ProductLabel to measuredPurityMain impurityLabCOA
Cagrilintide
5mg → 5.16mg
Over label +3.2%
99.43%
0.57% not itemisedils-labsOpen certificate Cagrilintide
GHK-Cu
100mg → 103.85mg
Over label +3.9%
99.96%
0.04% not itemisedils-labsOpen certificate GHK-Cu
KPV
10mg → 10.48mg
Over label +4.8%
99.64%
0.36% not itemisedils-labsOpen certificate KPV
OC-2TZ
60mg → 63.83mg
Over label +6.4%
99.82%
0.18% not itemisedils-labsOpen certificate OC-2TZ
OC-3RT
5mg → 5.34mg
Over label +6.8%
99.84%
0.16% not itemisedils-labsOpen certificate OC-3RT
SS-31
10mg → 10.7mg
Over label +7.0%
99.66%
0.34% not itemisedils-labsOpen certificate SS-31
SS-31
30mg → 31.25mg
Over label +4.2%
99.75%
0.25% not itemisedils-labsOpen certificate SS-31
Selank
10mg → 10.48mg
Over label +4.8%
99.62%
0.38% not itemisedils-labsOpen certificate Selank
Semax
10mg → 10.49mg
Over label +4.9%
99.9%
0.10% not itemisedils-labsOpen certificate Semax
TB-500
10mg → 10.48mg
Over label +4.8%
99.79%
0.21% not itemisedils-labsOpen certificate TB-500
DSIP
5mg → 5.06mg
On label +1.2%
99.03%
0.97% not itemisedvanguardOpen certificate DSIP
GLOWBlend, per-component content not listed
>99.8%
under 0.20% not itemisedvanguardOpen certificate GLOW
GLOWBlend, per-component content not listed
>99.8%
under 0.20% not itemisedvanguardOpen certificate GLOW
GLOWBlend, per-component content not listed
>99.5%
under 0.50% not itemisedvanguardOpen certificate GLOW
GLP2-T
30mg → 29.11mg
On label -3.0%
>99.8%
under 0.20% not itemisedvanguardOpen certificate GLP2-T
GLP3-R
20mg → 19.78mg
On label -1.1%
99.05%
0.95% not itemisedvanguardOpen certificate GLP3-R
Ipamorelin/CJC-1295Blend, per-component content not listed
99.73%
0.27% not itemisedvanguardOpen certificate Ipamorelin/CJC-1295
KLOWBlend, per-component content not listed
99.63%
0.37% not itemisedvanguardOpen certificate KLOW
KLOWBlend, per-component content not listed
>99.8%
under 0.20% not itemisedvanguardOpen certificate KLOW
KPV
10mg → 10.15mg
On label +1.5%
>99.8%
under 0.20% not itemisedvanguardOpen certificate KPV
PT-141
10mg → 10.3mg
On label +3.0%
99.87%
0.13% not itemisedils-labsOpen certificate PT-141
SS-31
10mg → 10.23mg
On label +2.3%
99.54%
0.46% not itemisedils-labsOpen certificate SS-31
Selank
10mg → 9.83mg
On label -1.7%
>99.8%
under 0.20% not itemisedvanguardOpen certificate Selank
TB-500 + BPC-157Blend, per-component content not listed
99.78%
0.22% not itemisedils-labsOpen certificate TB-500 + BPC-157
TB500 + BPC-157Blend, per-component content not listed
99.83%
0.17% not itemisedils-labsOpen certificate TB500 + BPC-157
WolverineBlend, per-component content not listed
>99.8%
under 0.20% not itemisedvanguardOpen certificate Wolverine

How this is checked

Vial content
Measured net peptide content against the size on the label. Within ±3% is on label, 3 to 10% is off label, beyond ±10% is a major deviation (under- or overfilled). When a certificate weighs several vials of the batch, the vial farthest from the label is the one judged, and with several purity results the lowest counts. Blends are only checked when the certificate lists each component.
Purity
HPLC purity on each certificate against the purity the supplier promises site-wide on its own website. Up to 1 point below the claim is amber, more than that is red. Only a direct promise counts (“99%+ purity guaranteed”); explanations of what purity means, one product's figure and page code are not treated as a claim. A certificate that reports only a bound (“>99%”) is judged only when the bound meets the claim, and a specification line is never read as a result.
Whose certificate
A certificate is only read once our client-identity review has looked at it, and one issued to a different company is left out, whether the automatic check or a manual review found it. A certificate issued to the company that runs the supplier's own website counts as the supplier's. A file hosted on another supplier's website is not counted for this one. The same rules decide which certificates appear on supplier and product pages. Only peptide certificates are read: bacteriostatic water, acetic acid and other diluents are left out, and so are product data sheets, which state a specification rather than a batch result.
Main impurity
Shown when the certificate itemises it: a named impurity (TFA, deletion sequence, oxidation…) or the largest secondary peak in the HPLC peak table. Most certificates report only a purity figure, so the rest of the sample is not itemised.
Trust Score
These checks are 10 of the 25 Transparency points: vial content 7 (full credit within ±3%, half up to ±10%, none beyond, over- and underfilled alike), purity 3 (98% is the bar when a supplier advertises no figure). Fewer than 5 readable results gives half credit rather than a guess.
Source and limits
These are the supplier's own published certificates, read automatically from the PDF or image. Janoshik results tables are read twice from the image, cell by cell, and a figure the two readings disagree on is left out rather than guessed. A certificate covers one batch on one date. We have not tested these batches ourselves.

One Day Compounds supplier page and all suppliers on Claims vs COA