Website claim: 99% purity. …ch close verified Certified U.S. Lab Tested. CoA Available. Purity ≥99% High-Purity Research Peptides Laboratory-grade peptides inte…
Source (read 2026-09-25)
- certificates read
- 45
- vials outside ±3% of label
- 3 / 3
- beyond ±10% (major)
- 3
- below advertised purity
- 2 / 45
On label, within ±3%Off label, 3 to 10%Major, beyond ±10%How this is checked
| Product | Label to measured | Purity | Main impurity | Lab | COA |
|---|---|---|---|---|---|
| GLP3RT20.pdf | 20mg → 23.96mg Overfilled +19.8% | 99.898% Meets 99% | 0.10% not itemised | freedom-diagnostics | Open certificate GLP3RT20.pdf |
| GLP-3 RT 20mg | 20mg → 23.29mg Overfilled +16.5% | 99.99% Meets 99% | 0.01% not itemised | freedom-diagnostics | Open certificate GLP-3 RT 20mg |
| IGF-1LR3 1mg | 1mg → 0.72mg Underfilled -28.0% | 99.15% Meets 99% | 0.85% not itemised | freedom-diagnostics | Open certificate IGF-1LR3 1mg |
| GLOW_GW0000015.pdf | Not measured | 98.8% 0.20 pts below 99% | 1.20% not itemised | Unknown | Open certificate GLOW_GW0000015.pdf |
| TESA_TS0000042.pdf | Not measured | 98.2% 0.80 pts below 99% | 1.80% not itemised | Unknown | Open certificate TESA_TS0000042.pdf |
| 5-amino-1mq_AM0000042.pdf | Not measured | 99.3% Meets 99% | 0.70% not itemised | Unknown | Open certificate 5-amino-1mq_AM0000042.pdf |
| BPC-157_BP0000046.pdf | Not measured | 99.7% Meets 99% | 0.30% not itemised | Unknown | Open certificate BPC-157_BP0000046.pdf |
| CJC-IPA_CJIP000012.pdf | Not measured | 99.8% Meets 99% | 0.20% not itemised | Unknown | Open certificate CJC-IPA_CJIP000012.pdf |
| GHK-Cu_GH0000023.pdf | Not measured | 99.7% Meets 99% | 0.30% not itemised | Unknown | Open certificate GHK-Cu_GH0000023.pdf |
| GLP-1-SM_SM0000038.pdf | Not measured | 99.7% Meets 99% | 0.30% not itemised | Unknown | Open certificate GLP-1-SM_SM0000038.pdf |
| GLP-2-TRZ_TZ0000030.pdf | Not measured | 99.8% Meets 99% | 0.20% not itemised | Unknown | Open certificate GLP-2-TRZ_TZ0000030.pdf |
| Gluta_GL000000038.pdf | Not measured | 99.7% Meets 99% | 0.30% not itemised | Unknown | Open certificate Gluta_GL000000038.pdf |
| IPA_IP0000030.pdf | Not measured | 99.9% Meets 99% | 0.10% not itemised | Unknown | Open certificate IPA_IP0000030.pdf |
| KPV_KPV000019.pdf | Not measured | 99.7% Meets 99% | 0.30% not itemised | Unknown | Open certificate KPV_KPV000019.pdf |
| MOTSC_MC0000028.pdf | Not measured | 99.8% Meets 99% | 0.20% not itemised | Unknown | Open certificate MOTSC_MC0000028.pdf |
| NAD_NAD.00000030.pdf | Not measured | 99.9% Meets 99% | 0.10% not itemised | Unknown | Open certificate NAD_NAD.00000030.pdf |
| SEMAX_SX0000028.pdf | Not measured | 99.8% Meets 99% | 0.20% not itemised | Unknown | Open certificate SEMAX_SX0000028.pdf |
| Selank_SK0000025.pdf | Not measured | 99.8% Meets 99% | 0.20% not itemised | Unknown | Open certificate Selank_SK0000025.pdf |
| TB-5000_TB0000030.pdf | Not measured | 99.7% Meets 99% | 0.30% not itemised | Unknown | Open certificate TB-5000_TB0000030.pdf |
| TESA10MG_0000043.pdf | Not measured | 99.4% Meets 99% | 0.60% not itemised | Unknown | Open certificate TESA10MG_0000043.pdf |
| Wolverin_W00000015.pdf | Not measured | 99.8% Meets 99% | 0.20% not itemised | Unknown | Open certificate Wolverin_W00000015.pdf |
| CJND000043.pdf | Not measured | 99.7% Meets 99% | 0.30% not itemised | Unknown | Open certificate CJND000043.pdf |
| CJWD00026.pdf | Not measured | 99.8% Meets 99% | 0.20% not itemised | Unknown | Open certificate CJWD00026.pdf |
| BW000000047_10_01.pdf | Not measured | 99.8% Meets 99% | 0.20% not itemised | Unknown | Open certificate BW000000047_10_01.pdf |
| GLP3RT10_RT0000033_01.pdf | Not measured | 99.7% Meets 99% | 0.30% not itemised | Unknown | Open certificate GLP3RT10_RT0000033_01.pdf |
| GLP3RT30_RT0000034_01.pdf | Not measured | 99.8% Meets 99% | 0.20% not itemised | Unknown | Open certificate GLP3RT30_RT0000034_01.pdf |
| KLOW_KL0000080_01.pdf | Not measured | 99.7% Meets 99% | 0.30% not itemised | Unknown | Open certificate KLOW_KL0000080_01.pdf |
| GLP2TRZ_TZ0000033_30MG.pdf | Not measured | 99.8% Meets 99% | 0.20% not itemised | Unknown | Open certificate GLP2TRZ_TZ0000033_30MG.pdf |
| GLP3RT_RT0000037_15MG.pdf | Not measured | 99.8% Meets 99% | 0.20% not itemised | Unknown | Open certificate GLP3RT_RT0000037_15MG.pdf |
| GLP3RT_RT0000039_60MG.pdf | Not measured | 99.8% Meets 99% | 0.20% not itemised | Unknown | Open certificate GLP3RT_RT0000039_60MG.pdf |
| GLP3RT_RT0000040_15MG.pdf | Not measured | 99.8% Meets 99% | 0.20% not itemised | Unknown | Open certificate GLP3RT_RT0000040_15MG.pdf |
| GLP3RT_RT0000041_30MG.pdf | Not measured | 99.8% Meets 99% | 0.20% not itemised | Unknown | Open certificate GLP3RT_RT0000041_30MG.pdf |
| RT0000035_1.pdf | Not measured | 99.7% Meets 99% | 0.30% not itemised | Unknown | Open certificate RT0000035_1.pdf |
| TS-IP_TSIP000020_10MG.pdf | Not measured | 99.7% Meets 99% | 0.30% not itemised | Unknown | Open certificate TS-IP_TSIP000020_10MG.pdf |
| AD0000010.pdf | Not measured | 99.7% Meets 99% | 0.30% not itemised | Unknown | Open certificate AD0000010.pdf |
| DP0000019.pdf | Not measured | 99.7% Meets 99% | 0.30% not itemised | Unknown | Open certificate DP0000019.pdf |
| GH0000024.pdf | Not measured | 99.7% Meets 99% | 0.30% not itemised | Unknown | Open certificate GH0000024.pdf |
| GL000000039.pdf | Not measured | 99.6% Meets 99% | 0.40% not itemised | Unknown | Open certificate GL000000039.pdf |
| IP0000031.pdf | Not measured | 99.9% Meets 99% | 0.10% not itemised | Unknown | Open certificate IP0000031.pdf |
| KPV000020.pdf | Not measured | 99.7% Meets 99% | 0.30% not itemised | Unknown | Open certificate KPV000020.pdf |
| MC0000029.pdf | Not measured | 99.8% Meets 99% | 0.20% not itemised | Unknown | Open certificate MC0000029.pdf |
| TS0000044.pdf | Not measured | 99.7% Meets 99% | 0.30% not itemised | Unknown | Open certificate TS0000044.pdf |
| TS0000045.pdf | Not measured | 99.7% Meets 99% | 0.30% not itemised | Unknown | Open certificate TS0000045.pdf |
| TZ0000035.pdf | Not measured | 99.9% Meets 99% | 0.10% not itemised | Unknown | Open certificate TZ0000035.pdf |
| W00000016.pdf | Not measured | 99.6% Meets 99% | 0.40% not itemised | Unknown | Open certificate W00000016.pdf |
How this is checked
- Vial content
- Measured net peptide content against the size on the label. Within ±3% is on label, 3 to 10% is off label, beyond ±10% is a major deviation (under- or overfilled). When a certificate weighs several vials of the batch, the vial farthest from the label is the one judged, and with several purity results the lowest counts. Blends are only checked when the certificate lists each component.
- Purity
- HPLC purity on each certificate against the purity the supplier promises site-wide on its own website. Up to 1 point below the claim is amber, more than that is red. Only a direct promise counts (“99%+ purity guaranteed”); explanations of what purity means, one product's figure and page code are not treated as a claim. A certificate that reports only a bound (“>99%”) is judged only when the bound meets the claim, and a specification line is never read as a result.
- Whose certificate
- A certificate is only read once our client-identity review has looked at it, and one issued to a different company is left out, whether the automatic check or a manual review found it. A certificate issued to the company that runs the supplier's own website counts as the supplier's. A file hosted on another supplier's website is not counted for this one. The same rules decide which certificates appear on supplier and product pages. Only peptide certificates are read: bacteriostatic water, acetic acid and other diluents are left out, and so are product data sheets, which state a specification rather than a batch result.
- Main impurity
- Shown when the certificate itemises it: a named impurity (TFA, deletion sequence, oxidation…) or the largest secondary peak in the HPLC peak table. Most certificates report only a purity figure, so the rest of the sample is not itemised.
- Trust Score
- These checks are 10 of the 25 Transparency points: vial content 7 (full credit within ±3%, half up to ±10%, none beyond, over- and underfilled alike), purity 3 (98% is the bar when a supplier advertises no figure). Fewer than 5 readable results gives half credit rather than a guess.
- Source and limits
- These are the supplier's own published certificates, read automatically from the PDF or image. Janoshik results tables are read twice from the image, cell by cell, and a figure the two readings disagree on is left out rather than guessed. A certificate covers one batch on one date. We have not tested these batches ourselves.
Vertex Labs supplier page and all suppliers on Claims vs COA