PeptideScanner

Claims vs COA / Vertex Labs

Vertex Labs: claims vs COA

Website claim: 99% purity. “…ch close verified Certified U.S. Lab Tested. CoA Available. Purity ≥99% High-Purity Research Peptides Laboratory-grade peptides inte…” Source (read 2026-09-25)
45
certificates read
3 / 3
vials outside ±3% of label
3
beyond ±10% (major)
2 / 45
below advertised purity
ProductLabel → measuredPurityMain impurityLabCOA
GLP3RT20.pdf
20mg → 23.96mg
Overfilled +19.8%
99.898%
Meets 99%
0.10% not itemisedfreedom-diagnosticsOpen
GLP-3 RT 20mg
20mg → 23.29mg
Overfilled +16.5%
99.99%
Meets 99%
0.01% not itemisedfreedom-diagnosticsOpen
IGF-1LR3 1mg
1mg → 0.72mg
Underfilled -28.0%
99.15%
Meets 99%
0.85% not itemisedfreedom-diagnosticsOpen
GLOW_GW0000015.pdfNot measured
98.8%
0.20 pts below 99%
1.20% not itemised—Open
TESA_TS0000042.pdfNot measured
98.2%
0.80 pts below 99%
1.80% not itemised—Open
5-amino-1mq_AM0000042.pdfNot measured
99.3%
Meets 99%
0.70% not itemised—Open
BPC-157_BP0000046.pdfNot measured
99.7%
Meets 99%
0.30% not itemised—Open
CJC-IPA_CJIP000012.pdfNot measured
99.8%
Meets 99%
0.20% not itemised—Open
GHK-Cu_GH0000023.pdfNot measured
99.7%
Meets 99%
0.30% not itemised—Open
GLP-1-SM_SM0000038.pdfNot measured
99.7%
Meets 99%
0.30% not itemised—Open
GLP-2-TRZ_TZ0000030.pdfNot measured
99.8%
Meets 99%
0.20% not itemised—Open
Gluta_GL000000038.pdfNot measured
99.7%
Meets 99%
0.30% not itemised—Open
IPA_IP0000030.pdfNot measured
99.9%
Meets 99%
0.10% not itemised—Open
KPV_KPV000019.pdfNot measured
99.7%
Meets 99%
0.30% not itemised—Open
MOTSC_MC0000028.pdfNot measured
99.8%
Meets 99%
0.20% not itemised—Open
NAD_NAD.00000030.pdfNot measured
99.9%
Meets 99%
0.10% not itemised—Open
SEMAX_SX0000028.pdfNot measured
99.8%
Meets 99%
0.20% not itemised—Open
Selank_SK0000025.pdfNot measured
99.8%
Meets 99%
0.20% not itemised—Open
TB-5000_TB0000030.pdfNot measured
99.7%
Meets 99%
0.30% not itemised—Open
TESA10MG_0000043.pdfNot measured
99.4%
Meets 99%
0.60% not itemised—Open
Wolverin_W00000015.pdfNot measured
99.8%
Meets 99%
0.20% not itemised—Open
CJND000043.pdfNot measured
99.7%
Meets 99%
0.30% not itemised—Open
CJWD00026.pdfNot measured
99.8%
Meets 99%
0.20% not itemised—Open
BW000000047_10_01.pdfNot measured
99.8%
Meets 99%
0.20% not itemised—Open
GLP3RT10_RT0000033_01.pdfNot measured
99.7%
Meets 99%
0.30% not itemised—Open
GLP3RT30_RT0000034_01.pdfNot measured
99.8%
Meets 99%
0.20% not itemised—Open
KLOW_KL0000080_01.pdfNot measured
99.7%
Meets 99%
0.30% not itemised—Open
GLP2TRZ_TZ0000033_30MG.pdfNot measured
99.8%
Meets 99%
0.20% not itemised—Open
GLP3RT_RT0000037_15MG.pdfNot measured
99.8%
Meets 99%
0.20% not itemised—Open
GLP3RT_RT0000039_60MG.pdfNot measured
99.8%
Meets 99%
0.20% not itemised—Open
GLP3RT_RT0000040_15MG.pdfNot measured
99.8%
Meets 99%
0.20% not itemised—Open
GLP3RT_RT0000041_30MG.pdfNot measured
99.8%
Meets 99%
0.20% not itemised—Open
RT0000035_1.pdfNot measured
99.7%
Meets 99%
0.30% not itemised—Open
TS-IP_TSIP000020_10MG.pdfNot measured
99.7%
Meets 99%
0.30% not itemised—Open
AD0000010.pdfNot measured
99.7%
Meets 99%
0.30% not itemised—Open
DP0000019.pdfNot measured
99.7%
Meets 99%
0.30% not itemised—Open
GH0000024.pdfNot measured
99.7%
Meets 99%
0.30% not itemised—Open
GL000000039.pdfNot measured
99.6%
Meets 99%
0.40% not itemised—Open
IP0000031.pdfNot measured
99.9%
Meets 99%
0.10% not itemised—Open
KPV000020.pdfNot measured
99.7%
Meets 99%
0.30% not itemised—Open
MC0000029.pdfNot measured
99.8%
Meets 99%
0.20% not itemised—Open
TS0000044.pdfNot measured
99.7%
Meets 99%
0.30% not itemised—Open
TS0000045.pdfNot measured
99.7%
Meets 99%
0.30% not itemised—Open
TZ0000035.pdfNot measured
99.9%
Meets 99%
0.10% not itemised—Open
W00000016.pdfNot measured
99.6%
Meets 99%
0.40% not itemised—Open

How this is checked

  • Vial content. Measured net peptide content against the size on the label. Within ±3% is on label, 3–10% is off label, beyond ±10% is a major deviation (under- or overfilled). When a certificate weighs several vials of the batch, the vial farthest from the label is the one judged, and with several purity results the lowest counts. Blends are only checked when the certificate lists each component.
  • Purity. HPLC purity on each certificate against the purity the supplier promises site-wide on its own website. Up to 1 point below the claim is amber, more than that is red. Only a direct promise counts (“99%+ purity guaranteed”); explanations of what purity means, one product's figure and page code are not treated as a claim. A certificate that reports only a bound (“>99%”) is judged only when the bound meets the claim, and a specification line is never read as a result.
  • Whose certificate. A certificate is only read once our client-identity review has looked at it, and one issued to a different company is left out — whether the automatic check or a manual review found it. A certificate issued to the company that runs the supplier's own website counts as the supplier's. A file hosted on another supplier's website is not counted for this one. The same rules decide which certificates appear on supplier and product pages. Only peptide certificates are read: bacteriostatic water, acetic acid and other diluents are left out, and so are product data sheets, which state a specification rather than a batch result.
  • Main impurity. Shown when the certificate itemises it: a named impurity (TFA, deletion sequence, oxidation…) or the largest secondary peak in the HPLC peak table. Most certificates report only a purity figure, so the rest of the sample is not itemised.
  • Trust Score. These checks are 10 of the 25 Transparency points: vial content 7 (full credit within ±3%, half up to ±10%, none beyond, over- and underfilled alike), purity 3 (98% is the bar when a supplier advertises no figure). Fewer than 5 readable results gives half credit rather than a guess.
  • These are the supplier's own published certificates, read automatically from the PDF or image. Janoshik results tables are read twice from the image, cell by cell, and a figure the two readings disagree on is left out rather than guessed. A certificate covers one batch on one date. We have not tested these batches ourselves.

Vertex Labs supplier page

Peptide Scanner is an independent aggregator. All content is for research purposes only. We do not sell, ship, or endorse any product. Read full disclaimer →