PeptideScanner
Peptide Scanner does not sell peptides. Independent, not affiliated with any supplier. Disclaimer

V8 Peptides: claims vs COA

The purity V8 Peptides advertises and the vial sizes on its labels, checked against the 12 certificates of analysis it publishes.

No site-wide purity promise found on the website. Vial content is still checked against the label.

certificates read
12
vials outside ±3% of label
7 / 11
beyond ±10% (major)
5
below advertised purity
None

On label, within ±3%Off label, 3 to 10%Major, beyond ±10%How this is checked

V8 Peptides certificates: label against measured content and purity
ProductLabel to measuredPurityMain impurityLabCOA
Fragment)
70mg → 77.66mg
Overfilled +10.9%
98.94%
1.06% not itemisedaccumark-labsOpen certificate Fragment)
MOTS-c
10mg → 11.1mg
Overfilled +11.0%
99.702%
0.30% not itemisedaccumark-labsOpen certificate MOTS-c
Semaglutide
10mg → 11.3mg
Overfilled +13.0%
99.746%
0.25% not itemisedaccumark-labsOpen certificate Semaglutide
Sermorelin
10mg → 12.47mg
Overfilled +24.7%
99.108%
0.89% not itemisedaccumark-labsOpen certificate Sermorelin
Tirzepatide
30mg → 33.07mg
Overfilled +10.2%
99.903%
0.10% not itemisedaccumark-labsOpen certificate Tirzepatide
17-23 Fragment)
80mg → 83.15mg
Over label +3.9%
99.79%
0.21% not itemisedaccumark-labsOpen certificate 17-23 Fragment)
GHK-Cu
100mg → 96.7mg
Under label -3.3%
99.08%
0.92% not itemisedaccumark-labsOpen certificate GHK-Cu
BPC-157
10mg → 9.74mg
On label -2.6%
99.39%
0.61% not itemisedaccumark-labsOpen certificate BPC-157
BPC-157, TB500 (17-23 Fragment)Blend, per-component content not listed
99.56%
0.44% not itemisedaccumark-labsOpen certificate BPC-157, TB500 (17-23 Fragment)
Retatrutide
10mg → 9.94mg
On label -0.6%
99.96%
0.04% not itemisedaccumark-labsOpen certificate Retatrutide
Retatrutide
20mg → 20.25mg
On label +1.3%
99.972%
0.03% not itemisedaccumark-labsOpen certificate Retatrutide
Tesamorelin
10mg → 9.94mg
On label -0.6%
99.33%
0.67% not itemisedaccumark-labsOpen certificate Tesamorelin

How this is checked

Vial content
Measured net peptide content against the size on the label. Within ±3% is on label, 3 to 10% is off label, beyond ±10% is a major deviation (under- or overfilled). When a certificate weighs several vials of the batch, the vial farthest from the label is the one judged, and with several purity results the lowest counts. Blends are only checked when the certificate lists each component.
Purity
HPLC purity on each certificate against the purity the supplier promises site-wide on its own website. Up to 1 point below the claim is amber, more than that is red. Only a direct promise counts (“99%+ purity guaranteed”); explanations of what purity means, one product's figure and page code are not treated as a claim. A certificate that reports only a bound (“>99%”) is judged only when the bound meets the claim, and a specification line is never read as a result.
Whose certificate
A certificate is only read once our client-identity review has looked at it, and one issued to a different company is left out, whether the automatic check or a manual review found it. A certificate issued to the company that runs the supplier's own website counts as the supplier's. A file hosted on another supplier's website is not counted for this one. The same rules decide which certificates appear on supplier and product pages. Only peptide certificates are read: bacteriostatic water, acetic acid and other diluents are left out, and so are product data sheets, which state a specification rather than a batch result.
Main impurity
Shown when the certificate itemises it: a named impurity (TFA, deletion sequence, oxidation…) or the largest secondary peak in the HPLC peak table. Most certificates report only a purity figure, so the rest of the sample is not itemised.
Trust Score
These checks are 10 of the 25 Transparency points: vial content 7 (full credit within ±3%, half up to ±10%, none beyond, over- and underfilled alike), purity 3 (98% is the bar when a supplier advertises no figure). Fewer than 5 readable results gives half credit rather than a guess.
Source and limits
These are the supplier's own published certificates, read automatically from the PDF or image. Janoshik results tables are read twice from the image, cell by cell, and a figure the two readings disagree on is left out rather than guessed. A certificate covers one batch on one date. We have not tested these batches ourselves.

V8 Peptides supplier page and all suppliers on Claims vs COA