Ultra Pure Bioscience: claims vs COA

The purity Ultra Pure Bioscience advertises and the vial sizes on its labels, checked against the 38 certificates of analysis it publishes.

No site-wide purity promise found on the website. Vial content is still checked against the label.

certificates read
38
vials outside ±3% of label
17 / 20
beyond ±10% (major)
12
below advertised purity
None

On label, within ±3%Off label, 3 to 10%Major, beyond ±10%How this is checked

Ultra Pure Bioscience certificates: label against measured content and purity
ProductLabel to measuredPurityMain impurityLabCOA
BPC-157 10mg
10mg → 12.27mg
Overfilled +22.7%
99.55%
0.45% not itemisedfreedom-diagnosticsOpen certificate BPC-157 10mg
CJC1295 with dac 5mg
5mg → 6.71mg
Overfilled +34.2%
99.727%
0.27% not itemisedfreedom-diagnosticsOpen certificate CJC1295 with dac 5mg
Cagrilintide 10mg
10mg → 11.11mg
Overfilled +11.1%
99.63%
0.37% not itemisedfreedom-diagnosticsOpen certificate Cagrilintide 10mg
Epithalon 50mg
50mg → 56.86mg
Overfilled +13.7%
99.8%
0.20% not itemisedfreedom-diagnosticsOpen certificate Epithalon 50mg
GHK 50mg
50mg → 43.82mg
Underfilled -12.4%
99.41%
0.59% not itemisedfreedom-diagnosticsOpen certificate GHK 50mg
PT-141 10mg
10mg → 11.62mg
Overfilled +16.2%
99.986%
0.01% not itemisedfreedom-diagnosticsOpen certificate PT-141 10mg
SS 31 10mg
10mg → 14.74mg
Overfilled +47.4%
99.74%
0.26% not itemisedfreedom-diagnosticsOpen certificate SS 31 10mg
Semaglutide 10mg
10mg → 11.23mg
Overfilled +12.3%
99.82%
0.18% not itemisedfreedom-diagnosticsOpen certificate Semaglutide 10mg
Thymosin Alpha1 10mg
10mg → 11.88mg
Overfilled +18.8%
99.363%
0.64% not itemisedfreedom-diagnosticsOpen certificate Thymosin Alpha1 10mg
Tirzepatide 10mg
10mg → 13.64mg
Overfilled +36.4%
99.78%
0.22% not itemisedfreedom-diagnosticsOpen certificate Tirzepatide 10mg
bpc-157, ghk-cu, kpv
TB-500: 10mg → 11.28mg Overfilled +12.8%
GHK-Cu: 50mg → 53.35mg Over label +6.7%
99.743%
0.26% not itemisedkovera-labsOpen certificate bpc-157, ghk-cu, kpv
selank
10mg → 11.97mg
Overfilled +19.7%
99.782%
0.22% not itemisedfreedom-diagnosticsOpen certificate selank
AOD-9604 5mg
5mg → 5.26mg
Over label +5.2%
99.219%
0.78% not itemisedfreedom-diagnosticsOpen certificate AOD-9604 5mg
Mots-C 10mg
10mg → 10.76mg
Over label +7.6%
99.758%
0.24% not itemisedfreedom-diagnosticsOpen certificate Mots-C 10mg
Retatrutide 10mg
10mg → 10.9mg
Over label +9.0%
99.92%
0.08% not itemisedfreedom-diagnosticsOpen certificate Retatrutide 10mg
TB-500 10mg
10mg → 9.6mg
Under label -4.0%
99.096%
0.90% not itemisedfreedom-diagnosticsOpen certificate TB-500 10mg
bpc-157, tb-500
BPC-157: 10mg → 10.39mg Over label +3.9%
TB-500: 10mg → 10.92mg Over label +9.2%
99.527%
0.47% not itemisedkovera-labsOpen certificate bpc-157, tb-500
BPC-157 10mgNot measured
99.55%
0.45% not itemisedfreedom-diagnosticsOpen certificate BPC-157 10mg
CAG/Sema 5/5mgBlend, per-component content not listed
99.771%
0.23% not itemisedfreedom-diagnosticsOpen certificate CAG/Sema 5/5mg
CagrilintideNot measured
99.64%
0.36% not itemisedfreedom-diagnosticsOpen certificate Cagrilintide
Epithalon 50mgNot measured
99.81%
0.19% not itemisedfreedom-diagnosticsOpen certificate Epithalon 50mg
GHK 50mgNot measured
99.43%
0.57% not itemisedfreedom-diagnosticsOpen certificate GHK 50mg
GHK-CU 100mg
100mg → 102.62mg
On label +2.6%
99.85%
0.15% not itemisedfreedom-diagnosticsOpen certificate GHK-CU 100mg
Glow 50/10/10mgBlend, per-component content not listed
99.71%
0.29% not itemisedfreedom-diagnosticsOpen certificate Glow 50/10/10mg
Glow 50/10/10mgBlend, per-component content not listed
99.71%
0.29% not itemisedfreedom-diagnosticsOpen certificate Glow 50/10/10mg
Ipamorelin 10mg
10mg → 10.22mg
On label +2.2%
99.9%
0.10% not itemisedfreedom-diagnosticsOpen certificate Ipamorelin 10mg
KPV
10mg → 10.03mg
On label +0.3%
>99.8%
under 0.20% not itemisedvanguardOpen certificate KPV
Retatrutide 10mgNot measured
99.92%
0.08% not itemisedfreedom-diagnosticsOpen certificate Retatrutide 10mg
S lutide 10Not measured
99.83%
0.17% not itemisedfreedom-diagnosticsOpen certificate S lutide 10
TESA/IPA Blend 10mg/5mgBlend, per-component content not listed
99.07%
0.93% not itemisedfreedom-diagnosticsOpen certificate TESA/IPA Blend 10mg/5mg
Ti ide 10Not measured
99.86%
0.14% not itemisedfreedom-diagnosticsOpen certificate Ti ide 10
Vitamin B12 10mlNot measured
98.247%
1.75% not itemisedfreedom-diagnosticsOpen certificate Vitamin B12 10ml
cjc-1295, ipamorelinBlend, per-component content not listed
99.3%
0.70% not itemisedkovera-labsOpen certificate cjc-1295, ipamorelin
dsip
— → 10.67mg
Not checked
99.62%
0.38% not itemisedkovera-labsOpen certificate dsip
igf-1-lr3
— → 1.18mg
Not checked
99.586%
0.41% not itemisedkovera-labsOpen certificate igf-1-lr3
tesamorelin
— → 9.47mg
Not checked
99.724%
0.28% not itemisedkovera-labsOpen certificate tesamorelin
tirzepatide
— → 62.01mg
Not checked
99.709%
0.29% not itemisedkovera-labsOpen certificate tirzepatide
tirzepatide
— → 31.28mg
Not checked
99.827%
0.17% not itemisedkovera-labsOpen certificate tirzepatide

How this is checked

Vial content
Measured net peptide content against the size on the label. Within ±3% is on label, 3 to 10% is off label, beyond ±10% is a major deviation (under- or overfilled). When a certificate weighs several vials of the batch, the vial farthest from the label is the one judged, and with several purity results the lowest counts. Blends are only checked when the certificate lists each component.
Purity
HPLC purity on each certificate against the purity the supplier promises site-wide on its own website. Up to 1 point below the claim is amber, more than that is red. Only a direct promise counts (“99%+ purity guaranteed”); explanations of what purity means, one product's figure and page code are not treated as a claim. A certificate that reports only a bound (“>99%”) is judged only when the bound meets the claim, and a specification line is never read as a result.
Whose certificate
A certificate is only read once our client-identity review has looked at it, and one issued to a different company is left out, whether the automatic check or a manual review found it. A certificate issued to the company that runs the supplier's own website counts as the supplier's. A file hosted on another supplier's website is not counted for this one. The same rules decide which certificates appear on supplier and product pages. Only peptide certificates are read: bacteriostatic water, acetic acid and other diluents are left out, and so are product data sheets, which state a specification rather than a batch result.
Main impurity
Shown when the certificate itemises it: a named impurity (TFA, deletion sequence, oxidation…) or the largest secondary peak in the HPLC peak table. Most certificates report only a purity figure, so the rest of the sample is not itemised.
Trust Score
These checks are 10 of the 25 Transparency points: vial content 7 (full credit within ±3%, half up to ±10%, none beyond, over- and underfilled alike), purity 3 (98% is the bar when a supplier advertises no figure). Fewer than 5 readable results gives half credit rather than a guess.
Source and limits
These are the supplier's own published certificates, read automatically from the PDF or image. Janoshik results tables are read twice from the image, cell by cell, and a figure the two readings disagree on is left out rather than guessed. A certificate covers one batch on one date. We have not tested these batches ourselves.

Ultra Pure Bioscience supplier page and all suppliers on Claims vs COA