PeptideScanner
Peptide Scanner does not sell peptides. Independent, not affiliated with any supplier. Disclaimer

Synova Supply: claims vs COA

The purity Synova Supply advertises and the vial sizes on its labels, checked against the 11 certificates of analysis it publishes.

Website claim: 99% purity. …s. Purity You Can Verify. Research peptides batch tested to ≥99% purity. Every order ships with a third-party Certificate of Analys… Source (read 2026-09-25)

certificates read
11
vials outside ±3% of label
0 / 10
beyond ±10% (major)
0
below advertised purity
0 / 11

On label, within ±3%Off label, 3 to 10%Major, beyond ±10%How this is checked

Synova Supply certificates: label against measured content and purity
ProductLabel to measuredPurityMain impurityLabCOA
BPC-157
10mg → 9.78mg
On label -2.2%
99.36%
Meets 99%
0.64% not itemisedhorizon-analyticalOpen certificate BPC-157
BPC-157Blend, per-component content not listed
99.32%
Meets 99%
0.68% not itemisedhorizon-analyticalOpen certificate BPC-157
CJC-1295 no DAC
10mg → 9.91mg
On label -0.9%
99.38%
Meets 99%
0.62% not itemisedhorizon-analyticalOpen certificate CJC-1295 no DAC
GHK-Cu
50mg → 48.9mg
On label -2.2%
99.54%
Meets 99%
0.46% not itemisedhorizon-analyticalOpen certificate GHK-Cu
Ipamorelin
10mg → 9.79mg
On label -2.1%
99.38%
Meets 99%
0.62% not itemisedhorizon-analyticalOpen certificate Ipamorelin
KPV
10mg → 10.15mg
On label +1.5%
99.28%
Meets 99%
0.72% not itemisedhorizon-analyticalOpen certificate KPV
MOTS-c
10mg → 9.88mg
On label -1.2%
99.39%
Meets 99%
0.61% not itemisedhorizon-analyticalOpen certificate MOTS-c
NAD+
500mg → 508mg
On label +1.6%
99.59%
Meets 99%
0.41% not itemisedhorizon-analyticalOpen certificate NAD+
Semax
10mg → 9.82mg
On label -1.8%
99.34%
Meets 99%
0.66% not itemisedhorizon-analyticalOpen certificate Semax
TB-500
10mg → 10.15mg
On label +1.5%
99.46%
Meets 99%
0.54% not itemisedhorizon-analyticalOpen certificate TB-500
Tesamorelin
10mg → 10.03mg
On label +0.3%
99.37%
Meets 99%
0.63% not itemisedhorizon-analyticalOpen certificate Tesamorelin

How this is checked

Vial content
Measured net peptide content against the size on the label. Within ±3% is on label, 3 to 10% is off label, beyond ±10% is a major deviation (under- or overfilled). When a certificate weighs several vials of the batch, the vial farthest from the label is the one judged, and with several purity results the lowest counts. Blends are only checked when the certificate lists each component.
Purity
HPLC purity on each certificate against the purity the supplier promises site-wide on its own website. Up to 1 point below the claim is amber, more than that is red. Only a direct promise counts (“99%+ purity guaranteed”); explanations of what purity means, one product's figure and page code are not treated as a claim. A certificate that reports only a bound (“>99%”) is judged only when the bound meets the claim, and a specification line is never read as a result.
Whose certificate
A certificate is only read once our client-identity review has looked at it, and one issued to a different company is left out, whether the automatic check or a manual review found it. A certificate issued to the company that runs the supplier's own website counts as the supplier's. A file hosted on another supplier's website is not counted for this one. The same rules decide which certificates appear on supplier and product pages. Only peptide certificates are read: bacteriostatic water, acetic acid and other diluents are left out, and so are product data sheets, which state a specification rather than a batch result.
Main impurity
Shown when the certificate itemises it: a named impurity (TFA, deletion sequence, oxidation…) or the largest secondary peak in the HPLC peak table. Most certificates report only a purity figure, so the rest of the sample is not itemised.
Trust Score
These checks are 10 of the 25 Transparency points: vial content 7 (full credit within ±3%, half up to ±10%, none beyond, over- and underfilled alike), purity 3 (98% is the bar when a supplier advertises no figure). Fewer than 5 readable results gives half credit rather than a guess.
Source and limits
These are the supplier's own published certificates, read automatically from the PDF or image. Janoshik results tables are read twice from the image, cell by cell, and a figure the two readings disagree on is left out rather than guessed. A certificate covers one batch on one date. We have not tested these batches ourselves.

Synova Supply supplier page and all suppliers on Claims vs COA