PeptideScanner

Claims vs COA / Secra Labs

Secra Labs: claims vs COA

Website claim: 99% purity. “…ation Affiliate Sign In / Dashboard RESEARCH GRADE PEPTIDES 99% purity guaranteed. Certificate of Analysis included with every ord…” Source (read 2026-09-25)
10
certificates read
2 / 8
vials outside ±3% of label
0
beyond ±10% (major)
0 / 10
below advertised purity
ProductLabel → measuredPurityMain impurityLabCOA
GLP-3 RT 10mg
10mg → 9.23mg
Under label -7.7%
99.32%
Meets 99%
0.68% not itemisedfreedom-diagnosticsOpen
Retatrutide 10mg
10mg → 9.23mg
Under label -7.7%
99.32%
Meets 99%
0.68% not itemisedfreedom-diagnosticsOpen
BPC-157 10mg
10mg → 9.93mg
On label -0.7%
99.5%
Meets 99%
0.50% not itemisedfreedom-diagnosticsOpen
BPC-157 10mg
10mg → 9.93mg
On label -0.7%
99.5%
Meets 99%
0.50% not itemisedfreedom-diagnosticsOpen
CJC-1295/Ipamorelin 5/5mgBlend, per-component content not listed
99.85%
Meets 99%
0.15% not itemisedfreedom-diagnosticsOpen
CJC-1295/Ipamorelin 5/5mgBlend, per-component content not listed
99.85%
Meets 99%
0.15% not itemisedfreedom-diagnosticsOpen
GHK-Cu 100mg
100mg → 102.78mg
On label +2.8%
99.78%
Meets 99%
0.22% not itemisedfreedom-diagnosticsOpen
GHK-Cu 100mg
100mg → 102.78mg
On label +2.8%
99.78%
Meets 99%
0.22% not itemisedfreedom-diagnosticsOpen
Melanotan 2 10mg
10mg → 10.03mg
On label +0.3%
99.96%
Meets 99%
0.04% not itemisedfreedom-diagnosticsOpen
Melanotan 2 10mg
10mg → 10.03mg
On label +0.3%
99.96%
Meets 99%
0.04% not itemisedfreedom-diagnosticsOpen

How this is checked

  • Vial content. Measured net peptide content against the size on the label. Within ±3% is on label, 3–10% is off label, beyond ±10% is a major deviation (under- or overfilled). When a certificate weighs several vials of the batch, the vial farthest from the label is the one judged, and with several purity results the lowest counts. Blends are only checked when the certificate lists each component.
  • Purity. HPLC purity on each certificate against the purity the supplier promises site-wide on its own website. Up to 1 point below the claim is amber, more than that is red. Only a direct promise counts (“99%+ purity guaranteed”); explanations of what purity means, one product's figure and page code are not treated as a claim. A certificate that reports only a bound (“>99%”) is judged only when the bound meets the claim, and a specification line is never read as a result.
  • Whose certificate. A certificate is only read once our client-identity review has looked at it, and one issued to a different company is left out — whether the automatic check or a manual review found it. A certificate issued to the company that runs the supplier's own website counts as the supplier's. A file hosted on another supplier's website is not counted for this one. The same rules decide which certificates appear on supplier and product pages. Only peptide certificates are read: bacteriostatic water, acetic acid and other diluents are left out, and so are product data sheets, which state a specification rather than a batch result.
  • Main impurity. Shown when the certificate itemises it: a named impurity (TFA, deletion sequence, oxidation…) or the largest secondary peak in the HPLC peak table. Most certificates report only a purity figure, so the rest of the sample is not itemised.
  • Trust Score. These checks are 10 of the 25 Transparency points: vial content 7 (full credit within ±3%, half up to ±10%, none beyond, over- and underfilled alike), purity 3 (98% is the bar when a supplier advertises no figure). Fewer than 5 readable results gives half credit rather than a guess.
  • These are the supplier's own published certificates, read automatically from the PDF or image. Janoshik results tables are read twice from the image, cell by cell, and a figure the two readings disagree on is left out rather than guessed. A certificate covers one batch on one date. We have not tested these batches ourselves.

Secra Labs supplier page

Peptide Scanner is an independent aggregator. All content is for research purposes only. We do not sell, ship, or endorse any product. Read full disclaimer →