PeptideScanner
Peptide Scanner does not sell peptides. Independent, not affiliated with any supplier. Disclaimer

RIVN Research: claims vs COA

The purity RIVN Research advertises and the vial sizes on its labels, checked against the 18 certificates of analysis it publishes.

No site-wide purity promise found on the website. Vial content is still checked against the label.

certificates read
18
vials outside ±3% of label
6 / 7
beyond ±10% (major)
5
below advertised purity
None

On label, within ±3%Off label, 3 to 10%Major, beyond ±10%How this is checked

RIVN Research certificates: label against measured content and purity
ProductLabel to measuredPurityMain impurityLabCOA
MOTS-c 40mg,
40mg → 48.31mg
Overfilled +20.8%
99.66%
0.34% not itemisedfreedom-diagnosticsOpen certificate MOTS-c 40mg,
NAD 500mg
500mg → 612.21mg
Overfilled +22.4%
99.96%
0.04% not itemisedfreedom-diagnosticsOpen certificate NAD 500mg
Tesamorelin 10mg
10mg → 13.15mg
Overfilled +31.5%
99.89%
0.11% not itemisedfreedom-diagnosticsOpen certificate Tesamorelin 10mg
Tirzepatide 30mg
30mg → 38.68mg
Overfilled +28.9%
99.91%
0.09% not itemisedfreedom-diagnosticsOpen certificate Tirzepatide 30mg
Tirzepatide 60mg
60mg → 68.91mg
Overfilled +14.9%
99.81%
0.19% not itemisedfreedom-diagnosticsOpen certificate Tirzepatide 60mg
DSIP 5mg
5mg → 5.32mg
Over label +6.4%
99.48%
0.52% not itemisedfreedom-diagnosticsOpen certificate DSIP 5mg
0c73e6_img_4635.pdfNot measured
99.8%
0.20% not itemisedfreedom-diagnosticsOpen certificate 0c73e6_img_4635.pdf
fcb297_img_7099-1.pdfNot measured
99.59%
0.41% not itemisedfreedom-diagnosticsOpen certificate fcb297_img_7099-1.pdf
00.9608 Sg bury oa.sex
— → 5.46mg
Not checked
99.56%
0.44% not itemisedfreedom-diagnosticsOpen certificate 00.9608 Sg bury oa.sex
IGF-1LR3 amgNot measured
99.76%
0.24% not itemisedfreedom-diagnosticsOpen certificate IGF-1LR3 amg
KLOW BLEND 80mgBlend, per-component content not listed
99.73%
0.27% not itemisedfreedom-diagnosticsOpen certificate KLOW BLEND 80mg
Kisspeptin 10mg
10mg → 18mg
Not checked
99.51%
0.49% not itemisedfreedom-diagnosticsOpen certificate Kisspeptin 10mg
MOTS.c 40mg
40mg → 40.35mg
On label +0.9%
99.86%
0.14% not itemisedfreedom-diagnosticsOpen certificate MOTS.c 40mg
NAD+ 1000m¢
— → 1024.48mg
Not checked
99.96%
0.04% not itemisedfreedom-diagnosticsOpen certificate NAD+ 1000m¢
P14] 1omg
— → 11.34mg
Not checked
99.91%
0.09% not itemisedfreedom-diagnosticsOpen certificate P14] 1omg
Thymosin Alpha-1 10mg
10mg → 1251mg
Not checked
99.7%
0.30% not itemisedfreedom-diagnosticsOpen certificate Thymosin Alpha-1 10mg
keV 20meNot measured
99.7%
0.30% not itemisedfreedom-diagnosticsOpen certificate keV 20me
pamoretin20me
— → 959mg
Not checked
99.67%
0.33% not itemisedfreedom-diagnosticsOpen certificate pamoretin20me

How this is checked

Vial content
Measured net peptide content against the size on the label. Within ±3% is on label, 3 to 10% is off label, beyond ±10% is a major deviation (under- or overfilled). When a certificate weighs several vials of the batch, the vial farthest from the label is the one judged, and with several purity results the lowest counts. Blends are only checked when the certificate lists each component.
Purity
HPLC purity on each certificate against the purity the supplier promises site-wide on its own website. Up to 1 point below the claim is amber, more than that is red. Only a direct promise counts (“99%+ purity guaranteed”); explanations of what purity means, one product's figure and page code are not treated as a claim. A certificate that reports only a bound (“>99%”) is judged only when the bound meets the claim, and a specification line is never read as a result.
Whose certificate
A certificate is only read once our client-identity review has looked at it, and one issued to a different company is left out, whether the automatic check or a manual review found it. A certificate issued to the company that runs the supplier's own website counts as the supplier's. A file hosted on another supplier's website is not counted for this one. The same rules decide which certificates appear on supplier and product pages. Only peptide certificates are read: bacteriostatic water, acetic acid and other diluents are left out, and so are product data sheets, which state a specification rather than a batch result.
Main impurity
Shown when the certificate itemises it: a named impurity (TFA, deletion sequence, oxidation…) or the largest secondary peak in the HPLC peak table. Most certificates report only a purity figure, so the rest of the sample is not itemised.
Trust Score
These checks are 10 of the 25 Transparency points: vial content 7 (full credit within ±3%, half up to ±10%, none beyond, over- and underfilled alike), purity 3 (98% is the bar when a supplier advertises no figure). Fewer than 5 readable results gives half credit rather than a guess.
Source and limits
These are the supplier's own published certificates, read automatically from the PDF or image. Janoshik results tables are read twice from the image, cell by cell, and a figure the two readings disagree on is left out rather than guessed. A certificate covers one batch on one date. We have not tested these batches ourselves.

RIVN Research supplier page and all suppliers on Claims vs COA