PeptideScanner

Claims vs COA / Research Peptides Lab

Research Peptides Lab: claims vs COA

No site-wide purity promise found on the website. Vial content is still checked against the label.
25
certificates read
5 / 5
vials outside ±3% of label
4
beyond ±10% (major)
—
below advertised purity
ProductLabel → measuredPurityMain impurityLabCOA
CJC-1295_20-_20ipamorelin_2010mg.png
10mg → 11.31mg
Overfilled +13.1%
99.423%
0.58% not itemisedfreedom-diagnosticsOpen
Selank_2010mg.png
10mg → 12.04mg
Overfilled +20.4%
99.583%
0.42% not itemisedfreedom-diagnosticsOpen
epitalon_2010mg.png
10mg → 11.73mg
Overfilled +17.3%
99.707%
0.29% not itemisedfreedom-diagnosticsOpen
melanotan_2010mg.png
10mg → 15.24mg
Overfilled +52.4%
99.835%
0.17% not itemisedfreedom-diagnosticsOpen
NAD_2B_20500mg.png
500mg → 525.56mg
Over label +5.1%
99.689%
0.31% not itemisedfreedom-diagnosticsOpen
AOD-9604_205mg.pngNot measured
99.724%
0.28% not itemisedfreedom-diagnosticsOpen
BPC_20157_20-_20tb4_205mg.pngNot measured
98.905%
1.09% not itemisedfreedom-diagnosticsOpen
BPC-157_2010mg.pngNot measured
99.268%
0.73% not itemisedfreedom-diagnosticsOpen
CJC-1295_20DAC_205mg.pngNot measured
99.07%
0.93% not itemisedfreedom-diagnosticsOpen
GHK-CU_20100mg.pngNot measured
99.18%
0.82% not itemisedfreedom-diagnosticsOpen
GLOW_20Blend_2070mg_20_lot_20Green-Purple_20Cap_.pngNot measured
99.72%
0.28% not itemisedfreedom-diagnosticsOpen
GLOW_20Blend_2070mg.pngNot measured
98.728%
1.27% not itemisedfreedom-diagnosticsOpen
IGF-1_20LR3_201mg.pngNot measured
95.718%
4.28% not itemisedfreedom-diagnosticsOpen
KLOW_2080mg.pngNot measured
99.83%
0.17% not itemisedfreedom-diagnosticsOpen
Mots-c_2010mg.pngNot measured
99.319%
0.68% not itemisedfreedom-diagnosticsOpen
PT-141_2010mg.pngNot measured
99.946%
0.05% not itemisedfreedom-diagnosticsOpen
Retatrutide_2010mg.pngNot measured
99.965%
0.03% not itemisedfreedom-diagnosticsOpen
TB-500_2010mg.pngNot measured
99.437%
0.56% not itemisedfreedom-diagnosticsOpen
Tesamorelin_2010mg.pngNot measured
99.162%
0.84% not itemisedfreedom-diagnosticsOpen
Thymosin_20alpha_201_2010mg.pngNot measured
99.791%
0.21% not itemisedfreedom-diagnosticsOpen
ipamorelin_2010mg.pngNot measured
99.856%
0.14% not itemisedfreedom-diagnosticsOpen
kisspeptin_2010mg.pngNot measured
99.739%
0.26% not itemisedfreedom-diagnosticsOpen
semaglutide_2010mg.pngNot measured
99.726%
0.27% not itemisedfreedom-diagnosticsOpen
sermorelin_205mg.pngNot measured
96.709%
3.29% not itemisedfreedom-diagnosticsOpen
tirzepatide_2010mg.pngNot measured
99.912%
0.09% not itemisedfreedom-diagnosticsOpen

How this is checked

  • Vial content. Measured net peptide content against the size on the label. Within ±3% is on label, 3–10% is off label, beyond ±10% is a major deviation (under- or overfilled). When a certificate weighs several vials of the batch, the vial farthest from the label is the one judged, and with several purity results the lowest counts. Blends are only checked when the certificate lists each component.
  • Purity. HPLC purity on each certificate against the purity the supplier promises site-wide on its own website. Up to 1 point below the claim is amber, more than that is red. Only a direct promise counts (“99%+ purity guaranteed”); explanations of what purity means, one product's figure and page code are not treated as a claim. A certificate that reports only a bound (“>99%”) is judged only when the bound meets the claim, and a specification line is never read as a result.
  • Whose certificate. A certificate is only read once our client-identity review has looked at it, and one issued to a different company is left out — whether the automatic check or a manual review found it. A certificate issued to the company that runs the supplier's own website counts as the supplier's. A file hosted on another supplier's website is not counted for this one. The same rules decide which certificates appear on supplier and product pages. Only peptide certificates are read: bacteriostatic water, acetic acid and other diluents are left out, and so are product data sheets, which state a specification rather than a batch result.
  • Main impurity. Shown when the certificate itemises it: a named impurity (TFA, deletion sequence, oxidation…) or the largest secondary peak in the HPLC peak table. Most certificates report only a purity figure, so the rest of the sample is not itemised.
  • Trust Score. These checks are 10 of the 25 Transparency points: vial content 7 (full credit within ±3%, half up to ±10%, none beyond, over- and underfilled alike), purity 3 (98% is the bar when a supplier advertises no figure). Fewer than 5 readable results gives half credit rather than a guess.
  • These are the supplier's own published certificates, read automatically from the PDF or image. Janoshik results tables are read twice from the image, cell by cell, and a figure the two readings disagree on is left out rather than guessed. A certificate covers one batch on one date. We have not tested these batches ourselves.

Research Peptides Lab supplier page

Peptide Scanner is an independent aggregator. All content is for research purposes only. We do not sell, ship, or endorse any product. Read full disclaimer →