No site-wide purity promise found on the website. Vial content is still checked against the label.
- certificates read
- 16
- vials outside ±3% of label
- 12 / 14
- beyond ±10% (major)
- 8
- below advertised purity
- None
On label, within ±3%Off label, 3 to 10%Major, beyond ±10%How this is checked
| Product | Label to measured | Purity | Main impurity | Lab | COA |
|---|---|---|---|---|---|
| 5-Amino-1Q 50mg | 50mg → 55.83mg Overfilled +11.7% | 99.3% | 0.70% not itemised | freedom-diagnostics | Open certificate 5-Amino-1Q 50mg |
| 5-Amino-1Q 50mg | 50mg → 55.83mg Overfilled +11.7% | 99.3% | 0.70% not itemised | freedom-diagnostics | Open certificate 5-Amino-1Q 50mg |
| ARA-290 10mg | 10mg → 11.16mg Overfilled +11.6% | 99.32% | 0.68% not itemised | freedom-diagnostics | Open certificate ARA-290 10mg |
| ARA-290 10mg | 10mg → 11.16mg Overfilled +11.6% | 99.32% | 0.68% not itemised | freedom-diagnostics | Open certificate ARA-290 10mg |
| Adipotide 10mg | 10mg → 8.09mg Underfilled -19.1% | 99.12% | 0.88% not itemised | freedom-diagnostics | Open certificate Adipotide 10mg |
| Adipotide 10mg | 10mg → 8.09mg Underfilled -19.1% | 99.12% | 0.88% not itemised | freedom-diagnostics | Open certificate Adipotide 10mg |
| BPC-157 10mg | 10mg → 11.55mg Overfilled +15.5% | 99.17% | 0.83% not itemised | freedom-diagnostics | Open certificate BPC-157 10mg |
| BPC-157 10mg | 10mg → 11.55mg Overfilled +15.5% | 99.17% | 0.83% not itemised | freedom-diagnostics | Open certificate BPC-157 10mg |
| AICAR 50mg | 50mg → 54.01mg Over label +8.0% | 99.89% | 0.11% not itemised | freedom-diagnostics | Open certificate AICAR 50mg |
| AICAR 50mg | 50mg → 54.01mg Over label +8.0% | 99.89% | 0.11% not itemised | freedom-diagnostics | Open certificate AICAR 50mg |
| BPC-157 10mg | 10mg → 10.66mg Over label +6.6% | 99.48% | 0.52% not itemised | freedom-diagnostics | Open certificate BPC-157 10mg |
| BPC-157 10mg | 10mg → 10.66mg Over label +6.6% | 99.48% | 0.52% not itemised | freedom-diagnostics | Open certificate BPC-157 10mg |
| ARA-290 10mg | 10mg → 9.84mg On label -1.6% | 99.26% | 0.74% not itemised | freedom-diagnostics | Open certificate ARA-290 10mg |
| ARA-290 10mg | 10mg → 9.84mg On label -1.6% | 99.26% | 0.74% not itemised | freedom-diagnostics | Open certificate ARA-290 10mg |
| BPC-157/TB-500 10/10mg | Blend, per-component content not listed | 99.39% | 0.61% not itemised | freedom-diagnostics | Open certificate BPC-157/TB-500 10/10mg |
| BPC-157/TB-500 10/10mg | Blend, per-component content not listed | 99.39% | 0.61% not itemised | freedom-diagnostics | Open certificate BPC-157/TB-500 10/10mg |
How this is checked
- Vial content
- Measured net peptide content against the size on the label. Within ±3% is on label, 3 to 10% is off label, beyond ±10% is a major deviation (under- or overfilled). When a certificate weighs several vials of the batch, the vial farthest from the label is the one judged, and with several purity results the lowest counts. Blends are only checked when the certificate lists each component.
- Purity
- HPLC purity on each certificate against the purity the supplier promises site-wide on its own website. Up to 1 point below the claim is amber, more than that is red. Only a direct promise counts (“99%+ purity guaranteed”); explanations of what purity means, one product's figure and page code are not treated as a claim. A certificate that reports only a bound (“>99%”) is judged only when the bound meets the claim, and a specification line is never read as a result.
- Whose certificate
- A certificate is only read once our client-identity review has looked at it, and one issued to a different company is left out, whether the automatic check or a manual review found it. A certificate issued to the company that runs the supplier's own website counts as the supplier's. A file hosted on another supplier's website is not counted for this one. The same rules decide which certificates appear on supplier and product pages. Only peptide certificates are read: bacteriostatic water, acetic acid and other diluents are left out, and so are product data sheets, which state a specification rather than a batch result.
- Main impurity
- Shown when the certificate itemises it: a named impurity (TFA, deletion sequence, oxidation…) or the largest secondary peak in the HPLC peak table. Most certificates report only a purity figure, so the rest of the sample is not itemised.
- Trust Score
- These checks are 10 of the 25 Transparency points: vial content 7 (full credit within ±3%, half up to ±10%, none beyond, over- and underfilled alike), purity 3 (98% is the bar when a supplier advertises no figure). Fewer than 5 readable results gives half credit rather than a guess.
- Source and limits
- These are the supplier's own published certificates, read automatically from the PDF or image. Janoshik results tables are read twice from the image, cell by cell, and a figure the two readings disagree on is left out rather than guessed. A certificate covers one batch on one date. We have not tested these batches ourselves.
Pure Peptide Labs supplier page and all suppliers on Claims vs COA