PeptideScanner
Peptide Scanner does not sell peptides. Independent, not affiliated with any supplier. Disclaimer

Prime Peptides US: claims vs COA

The purity Prime Peptides US advertises and the vial sizes on its labels, checked against the 14 certificates of analysis it publishes.

No site-wide purity promise found on the website. Vial content is still checked against the label.

certificates read
14
vials outside ±3% of label
8 / 10
beyond ±10% (major)
6
below advertised purity
None

On label, within ±3%Off label, 3 to 10%Major, beyond ±10%How this is checked

Prime Peptides US certificates: label against measured content and purity
ProductLabel to measuredPurityMain impurityLabCOA
BPC-157 10mg
10mg → 11.08mg
Overfilled +10.8%
99.63%
0.37% not itemisedfreedom-diagnosticsOpen certificate BPC-157 10mg
Reta 30mg
30mg → 36.37mg
Overfilled +21.2%
99.97%
0.03% not itemisedfreedom-diagnosticsOpen certificate Reta 30mg
Sema, 10mg
10mg → 11.43mg
Overfilled +14.3%
99.91%
0.09% not itemisedfreedom-diagnosticsOpen certificate Sema, 10mg
Sema, 15mg
15mg → 17.5mg
Overfilled +16.7%
99.83%
0.17% not itemisedfreedom-diagnosticsOpen certificate Sema, 15mg
Semaglutide
5mg → 5.51mg
Overfilled +10.2%
99.02%
0.98% not itemisedvanguardOpen certificate Semaglutide
Tirz 30mg
30mg → 34.99mg
Overfilled +16.6%
99.91%
0.09% not itemisedfreedom-diagnosticsOpen certificate Tirz 30mg
Ipa-April-Testing-.pdf
10mg → 10.44mg
Over label +4.4%
99.8%
0.20% not itemisedbioviridianOpen certificate Ipa-April-Testing-.pdf
Tirz 30mg
30mg → 31.2mg
Over label +4.0%
99.97%
0.03% not itemisedfreedom-diagnosticsOpen certificate Tirz 30mg
Glutathione-April-Test.pdf
1500mg → 1508.43mg
On label +0.6%
99.8%
0.20% not itemisedbioviridianOpen certificate Glutathione-April-Test.pdf
NAD-March-Test-BIOVIRIDIAN.pdfNot measured
99.8%
0.20% not itemisedbioviridianOpen certificate NAD-March-Test-BIOVIRIDIAN.pdf
Tir-10mg-April-Testing-.pdfNot measured
99.8%
0.20% not itemisedbioviridianOpen certificate Tir-10mg-April-Testing-.pdf
GHK-Cu
100mg → 99.5mg
On label -0.5%
99.48%
0.52% not itemisedhorizon-analyticalOpen certificate GHK-Cu
RetatrutideNot measured
99.786%
0.21% not itemisedUnknownOpen certificate Retatrutide
Wolverine 10/10Blend, per-component content not listed
99.41%
0.59% not itemisedfreedom-diagnosticsOpen certificate Wolverine 10/10

How this is checked

Vial content
Measured net peptide content against the size on the label. Within ±3% is on label, 3 to 10% is off label, beyond ±10% is a major deviation (under- or overfilled). When a certificate weighs several vials of the batch, the vial farthest from the label is the one judged, and with several purity results the lowest counts. Blends are only checked when the certificate lists each component.
Purity
HPLC purity on each certificate against the purity the supplier promises site-wide on its own website. Up to 1 point below the claim is amber, more than that is red. Only a direct promise counts (“99%+ purity guaranteed”); explanations of what purity means, one product's figure and page code are not treated as a claim. A certificate that reports only a bound (“>99%”) is judged only when the bound meets the claim, and a specification line is never read as a result.
Whose certificate
A certificate is only read once our client-identity review has looked at it, and one issued to a different company is left out, whether the automatic check or a manual review found it. A certificate issued to the company that runs the supplier's own website counts as the supplier's. A file hosted on another supplier's website is not counted for this one. The same rules decide which certificates appear on supplier and product pages. Only peptide certificates are read: bacteriostatic water, acetic acid and other diluents are left out, and so are product data sheets, which state a specification rather than a batch result.
Main impurity
Shown when the certificate itemises it: a named impurity (TFA, deletion sequence, oxidation…) or the largest secondary peak in the HPLC peak table. Most certificates report only a purity figure, so the rest of the sample is not itemised.
Trust Score
These checks are 10 of the 25 Transparency points: vial content 7 (full credit within ±3%, half up to ±10%, none beyond, over- and underfilled alike), purity 3 (98% is the bar when a supplier advertises no figure). Fewer than 5 readable results gives half credit rather than a guess.
Source and limits
These are the supplier's own published certificates, read automatically from the PDF or image. Janoshik results tables are read twice from the image, cell by cell, and a figure the two readings disagree on is left out rather than guessed. A certificate covers one batch on one date. We have not tested these batches ourselves.

Prime Peptides US supplier page and all suppliers on Claims vs COA