PeptideScanner
Peptide Scanner does not sell peptides. Independent, not affiliated with any supplier. Disclaimer

Precision Research Peptides: claims vs COA

The purity Precision Research Peptides advertises and the vial sizes on its labels, checked against the 28 certificates of analysis it publishes.

No site-wide purity promise found on the website. Vial content is still checked against the label.

certificates read
28
vials outside ±3% of label
17 / 18
beyond ±10% (major)
12
below advertised purity
None

On label, within ±3%Off label, 3 to 10%Major, beyond ±10%How this is checked

Precision Research Peptides certificates: label against measured content and purity
ProductLabel to measuredPurityMain impurityLabCOA
8500 Smg
5mg → 6.39mg
Overfilled +27.8%
99.1%
0.90% not itemisedfreedom-diagnosticsOpen certificate 8500 Smg
BC 10mg
10mg → 12.43mg
Overfilled +24.3%
99.23%
0.77% not itemisedfreedom-diagnosticsOpen certificate BC 10mg
GLP-3R 20mg
20mg → 23.57mg
Overfilled +17.9%
99.92%
0.08% not itemisedfreedom-diagnosticsOpen certificate GLP-3R 20mg
GLP-S 10mg
10mg → 12.16mg
Overfilled +21.6%
99.93%
0.07% not itemisedfreedom-diagnosticsOpen certificate GLP-S 10mg
IPAMO 10mg
10mg → 13.29mg
Overfilled +32.9%
99.64%
0.36% not itemisedfreedom-diagnosticsOpen certificate IPAMO 10mg
KPV 10mg
10mg → 11.42mg
Overfilled +14.2%
99.65%
0.35% not itemisedfreedom-diagnosticsOpen certificate KPV 10mg
MOTS C 10mg
10mg → 11.55mg
Overfilled +15.5%
99.72%
0.28% not itemisedfreedom-diagnosticsOpen certificate MOTS C 10mg
RT 10mg
10mg → 11.27mg
Overfilled +12.7%
99.78%
0.22% not itemisedfreedom-diagnosticsOpen certificate RT 10mg
RT 20mg
20mg → 23.93mg
Overfilled +19.7%
99.87%
0.13% not itemisedfreedom-diagnosticsOpen certificate RT 20mg
SERMO Smeg,
5mg → 6.18mg
Overfilled +23.6%
99.29%
0.71% not itemisedfreedom-diagnosticsOpen certificate SERMO Smeg,
SS-31 10mg
10mg → 12.54mg
Overfilled +25.4%
99.78%
0.22% not itemisedfreedom-diagnosticsOpen certificate SS-31 10mg
TR 10mg
10mg → 13.29mg
Overfilled +32.9%
99.93%
0.07% not itemisedfreedom-diagnosticsOpen certificate TR 10mg
GHK-CU 100mg
100mg → 94.87mg
Under label -5.1%
99.66%
0.34% not itemisedfreedom-diagnosticsOpen certificate GHK-CU 100mg
NAD+ 500mg
500mg → 526.21mg
Over label +5.2%
99.91%
0.09% not itemisedfreedom-diagnosticsOpen certificate NAD+ 500mg
RT 40mg
40mg → 41.77mg
Over label +4.4%
99.79%
0.21% not itemisedfreedom-diagnosticsOpen certificate RT 40mg
SM 10mg
10mg → 9.01mg
Under label -9.9%
99.86%
0.14% not itemisedfreedom-diagnosticsOpen certificate SM 10mg
TR20 20mg
20mg → 21.35mg
Over label +6.8%
99.89%
0.11% not itemisedfreedom-diagnosticsOpen certificate TR20 20mg
6f6c3c_coa-pt141-pt-14110-2608-2708.jpg
— → 10.43mg
Not checked
99.83%
0.17% not itemisedfreedom-diagnosticsOpen certificate 6f6c3c_coa-pt141-pt-14110-2608-2708.jpg
00 10mgNot measured
99.01%
0.99% not itemisedfreedom-diagnosticsOpen certificate 00 10mg
AOD-9604 Smg
— → 6.22mg
Not checked
99.52%
0.48% not itemisedfreedom-diagnosticsOpen certificate AOD-9604 Smg
BPC Smg +78 SmeBlend, per-component content not listed
99.16%
0.84% not itemisedfreedom-diagnosticsOpen certificate BPC Smg +78 Sme
Epithalon 40mg
40mg → 40.62mg
On label +1.6%
99.85%
0.15% not itemisedfreedom-diagnosticsOpen certificate Epithalon 40mg
GHK-Cu
— → 58.33mg
Not checked
99.62%
0.38% not itemisedfreedom-diagnosticsOpen certificate GHK-Cu
GLOW 70mgBlend, per-component content not listed
99.63%
0.37% not itemisedfreedom-diagnosticsOpen certificate GLOW 70mg
Glow 70mgBlend, per-component content not listed
99.86%
0.14% not itemisedfreedom-diagnosticsOpen certificate Glow 70mg
IGF-1LR3 Img
1mg → 130mg
Not checked
99.71%
0.29% not itemisedfreedom-diagnosticsOpen certificate IGF-1LR3 Img
KLOW 80mgBlend, per-component content not listed
99.78%
0.22% not itemisedfreedom-diagnosticsOpen certificate KLOW 80mg
cic-1295 + PAMOBlend, per-component content not listed
99.89%
0.11% not itemisedfreedom-diagnosticsOpen certificate cic-1295 + PAMO

How this is checked

Vial content
Measured net peptide content against the size on the label. Within ±3% is on label, 3 to 10% is off label, beyond ±10% is a major deviation (under- or overfilled). When a certificate weighs several vials of the batch, the vial farthest from the label is the one judged, and with several purity results the lowest counts. Blends are only checked when the certificate lists each component.
Purity
HPLC purity on each certificate against the purity the supplier promises site-wide on its own website. Up to 1 point below the claim is amber, more than that is red. Only a direct promise counts (“99%+ purity guaranteed”); explanations of what purity means, one product's figure and page code are not treated as a claim. A certificate that reports only a bound (“>99%”) is judged only when the bound meets the claim, and a specification line is never read as a result.
Whose certificate
A certificate is only read once our client-identity review has looked at it, and one issued to a different company is left out, whether the automatic check or a manual review found it. A certificate issued to the company that runs the supplier's own website counts as the supplier's. A file hosted on another supplier's website is not counted for this one. The same rules decide which certificates appear on supplier and product pages. Only peptide certificates are read: bacteriostatic water, acetic acid and other diluents are left out, and so are product data sheets, which state a specification rather than a batch result.
Main impurity
Shown when the certificate itemises it: a named impurity (TFA, deletion sequence, oxidation…) or the largest secondary peak in the HPLC peak table. Most certificates report only a purity figure, so the rest of the sample is not itemised.
Trust Score
These checks are 10 of the 25 Transparency points: vial content 7 (full credit within ±3%, half up to ±10%, none beyond, over- and underfilled alike), purity 3 (98% is the bar when a supplier advertises no figure). Fewer than 5 readable results gives half credit rather than a guess.
Source and limits
These are the supplier's own published certificates, read automatically from the PDF or image. Janoshik results tables are read twice from the image, cell by cell, and a figure the two readings disagree on is left out rather than guessed. A certificate covers one batch on one date. We have not tested these batches ourselves.

Precision Research Peptides supplier page and all suppliers on Claims vs COA