No site-wide purity promise found on the website. Vial content is still checked against the label.
- certificates read
- 28
- vials outside ±3% of label
- 17 / 18
- beyond ±10% (major)
- 12
- below advertised purity
- None
On label, within ±3%Off label, 3 to 10%Major, beyond ±10%How this is checked
| Product | Label to measured | Purity | Main impurity | Lab | COA |
|---|---|---|---|---|---|
| 8500 Smg | 5mg → 6.39mg Overfilled +27.8% | 99.1% | 0.90% not itemised | freedom-diagnostics | Open certificate 8500 Smg |
| BC 10mg | 10mg → 12.43mg Overfilled +24.3% | 99.23% | 0.77% not itemised | freedom-diagnostics | Open certificate BC 10mg |
| GLP-3R 20mg | 20mg → 23.57mg Overfilled +17.9% | 99.92% | 0.08% not itemised | freedom-diagnostics | Open certificate GLP-3R 20mg |
| GLP-S 10mg | 10mg → 12.16mg Overfilled +21.6% | 99.93% | 0.07% not itemised | freedom-diagnostics | Open certificate GLP-S 10mg |
| IPAMO 10mg | 10mg → 13.29mg Overfilled +32.9% | 99.64% | 0.36% not itemised | freedom-diagnostics | Open certificate IPAMO 10mg |
| KPV 10mg | 10mg → 11.42mg Overfilled +14.2% | 99.65% | 0.35% not itemised | freedom-diagnostics | Open certificate KPV 10mg |
| MOTS C 10mg | 10mg → 11.55mg Overfilled +15.5% | 99.72% | 0.28% not itemised | freedom-diagnostics | Open certificate MOTS C 10mg |
| RT 10mg | 10mg → 11.27mg Overfilled +12.7% | 99.78% | 0.22% not itemised | freedom-diagnostics | Open certificate RT 10mg |
| RT 20mg | 20mg → 23.93mg Overfilled +19.7% | 99.87% | 0.13% not itemised | freedom-diagnostics | Open certificate RT 20mg |
| SERMO Smeg, | 5mg → 6.18mg Overfilled +23.6% | 99.29% | 0.71% not itemised | freedom-diagnostics | Open certificate SERMO Smeg, |
| SS-31 10mg | 10mg → 12.54mg Overfilled +25.4% | 99.78% | 0.22% not itemised | freedom-diagnostics | Open certificate SS-31 10mg |
| TR 10mg | 10mg → 13.29mg Overfilled +32.9% | 99.93% | 0.07% not itemised | freedom-diagnostics | Open certificate TR 10mg |
| GHK-CU 100mg | 100mg → 94.87mg Under label -5.1% | 99.66% | 0.34% not itemised | freedom-diagnostics | Open certificate GHK-CU 100mg |
| NAD+ 500mg | 500mg → 526.21mg Over label +5.2% | 99.91% | 0.09% not itemised | freedom-diagnostics | Open certificate NAD+ 500mg |
| RT 40mg | 40mg → 41.77mg Over label +4.4% | 99.79% | 0.21% not itemised | freedom-diagnostics | Open certificate RT 40mg |
| SM 10mg | 10mg → 9.01mg Under label -9.9% | 99.86% | 0.14% not itemised | freedom-diagnostics | Open certificate SM 10mg |
| TR20 20mg | 20mg → 21.35mg Over label +6.8% | 99.89% | 0.11% not itemised | freedom-diagnostics | Open certificate TR20 20mg |
| 6f6c3c_coa-pt141-pt-14110-2608-2708.jpg | — → 10.43mg Not checked | 99.83% | 0.17% not itemised | freedom-diagnostics | Open certificate 6f6c3c_coa-pt141-pt-14110-2608-2708.jpg |
| 00 10mg | Not measured | 99.01% | 0.99% not itemised | freedom-diagnostics | Open certificate 00 10mg |
| AOD-9604 Smg | — → 6.22mg Not checked | 99.52% | 0.48% not itemised | freedom-diagnostics | Open certificate AOD-9604 Smg |
| BPC Smg +78 Sme | Blend, per-component content not listed | 99.16% | 0.84% not itemised | freedom-diagnostics | Open certificate BPC Smg +78 Sme |
| Epithalon 40mg | 40mg → 40.62mg On label +1.6% | 99.85% | 0.15% not itemised | freedom-diagnostics | Open certificate Epithalon 40mg |
| GHK-Cu | — → 58.33mg Not checked | 99.62% | 0.38% not itemised | freedom-diagnostics | Open certificate GHK-Cu |
| GLOW 70mg | Blend, per-component content not listed | 99.63% | 0.37% not itemised | freedom-diagnostics | Open certificate GLOW 70mg |
| Glow 70mg | Blend, per-component content not listed | 99.86% | 0.14% not itemised | freedom-diagnostics | Open certificate Glow 70mg |
| IGF-1LR3 Img | 1mg → 130mg Not checked | 99.71% | 0.29% not itemised | freedom-diagnostics | Open certificate IGF-1LR3 Img |
| KLOW 80mg | Blend, per-component content not listed | 99.78% | 0.22% not itemised | freedom-diagnostics | Open certificate KLOW 80mg |
| cic-1295 + PAMO | Blend, per-component content not listed | 99.89% | 0.11% not itemised | freedom-diagnostics | Open certificate cic-1295 + PAMO |
How this is checked
- Vial content
- Measured net peptide content against the size on the label. Within ±3% is on label, 3 to 10% is off label, beyond ±10% is a major deviation (under- or overfilled). When a certificate weighs several vials of the batch, the vial farthest from the label is the one judged, and with several purity results the lowest counts. Blends are only checked when the certificate lists each component.
- Purity
- HPLC purity on each certificate against the purity the supplier promises site-wide on its own website. Up to 1 point below the claim is amber, more than that is red. Only a direct promise counts (“99%+ purity guaranteed”); explanations of what purity means, one product's figure and page code are not treated as a claim. A certificate that reports only a bound (“>99%”) is judged only when the bound meets the claim, and a specification line is never read as a result.
- Whose certificate
- A certificate is only read once our client-identity review has looked at it, and one issued to a different company is left out, whether the automatic check or a manual review found it. A certificate issued to the company that runs the supplier's own website counts as the supplier's. A file hosted on another supplier's website is not counted for this one. The same rules decide which certificates appear on supplier and product pages. Only peptide certificates are read: bacteriostatic water, acetic acid and other diluents are left out, and so are product data sheets, which state a specification rather than a batch result.
- Main impurity
- Shown when the certificate itemises it: a named impurity (TFA, deletion sequence, oxidation…) or the largest secondary peak in the HPLC peak table. Most certificates report only a purity figure, so the rest of the sample is not itemised.
- Trust Score
- These checks are 10 of the 25 Transparency points: vial content 7 (full credit within ±3%, half up to ±10%, none beyond, over- and underfilled alike), purity 3 (98% is the bar when a supplier advertises no figure). Fewer than 5 readable results gives half credit rather than a guess.
- Source and limits
- These are the supplier's own published certificates, read automatically from the PDF or image. Janoshik results tables are read twice from the image, cell by cell, and a figure the two readings disagree on is left out rather than guessed. A certificate covers one batch on one date. We have not tested these batches ourselves.
Precision Research Peptides supplier page and all suppliers on Claims vs COA