PeptideScanner
Peptide Scanner does not sell peptides. Independent, not affiliated with any supplier. Disclaimer

Peptide Clyde: claims vs COA

The purity Peptide Clyde advertises and the vial sizes on its labels, checked against the 24 certificates of analysis it publishes.

Website claim: 98% purity. …Buy Research Peptides UK | ≥98% Purity | Peptide Clyde Dispatched · Flat-Rate Shipping €10 · 3-5 d… Source (read 2026-09-25)

certificates read
24
vials outside ±3% of label
0 / 1
beyond ±10% (major)
0
below advertised purity
0 / 23

On label, within ±3%Off label, 3 to 10%Major, beyond ±10%How this is checked

Peptide Clyde certificates: label against measured content and purity
ProductLabel to measuredPurityMain impurityLabCOA
5-amino-1mq 10mgNot measured
99.2%
Meets 98%
0.80% not itemisedjanoshikOpen certificate 5-amino-1mq 10mg
AOD9604 10mgNot measured
99.7%
Meets 98%
0.30% not itemisedjanoshikOpen certificate AOD9604 10mg
AOD9604 5mgNot measured
98.6%
Meets 98%
1.40% not itemisedjanoshikOpen certificate AOD9604 5mg
BPC 157 10mgNot measured
98.4%
Meets 98%
1.60% not itemisedjanoshikOpen certificate BPC 157 10mg
CJC-1295 NO DAC 10mgNot measured
99.4%
Meets 98%
0.60% not itemisedjanoshikOpen certificate CJC-1295 NO DAC 10mg
CJC-1295 with DAC 10mgNot measured
99.2%
Meets 98%
0.80% not itemisedjanoshikOpen certificate CJC-1295 with DAC 10mg
Cagrilintide 10mg
10mg → 9.96mg
On label -0.4%
Not readNot itemisedjanoshikOpen certificate Cagrilintide 10mg
Epithalon 10mgNot measured
98.9%
Meets 98%
1.10% not itemisedjanoshikOpen certificate Epithalon 10mg
Epithalon 50mgNot measured
99.88%
Meets 98%
0.12% not itemisedjanoshikOpen certificate Epithalon 50mg
GHK-CU 100mgNot measured
99.99%
Meets 98%
0.01% not itemisedjanoshikOpen certificate GHK-CU 100mg
GHK-CU 50mgNot measured
99.74%
Meets 98%
0.26% not itemisedjanoshikOpen certificate GHK-CU 50mg
IGF-1LR3 0.1mgNot measured
99%
Meets 98%
1.00% not itemisedjanoshikOpen certificate IGF-1LR3 0.1mg
IGF-1LR3 Img
— → 0.98mg
Not checked
98%
Meets 98%
2.00% not itemisedjanoshikOpen certificate IGF-1LR3 Img
Ipamorelin 10mgNot measured
99.6%
Meets 98%
0.40% not itemisedjanoshikOpen certificate Ipamorelin 10mg
MOTS-c 10mgNot measured
99.9%
Meets 98%
0.10% not itemisedjanoshikOpen certificate MOTS-c 10mg
NAD 1000mgNot measured
99.54%
Meets 98%
0.46% not itemisedjanoshikOpen certificate NAD 1000mg
NAD 100mgNot measured
99%
Meets 98%
1.00% not itemisedjanoshikOpen certificate NAD 100mg
NAD 500mgNot measured
100%
Meets 98%
Not itemisedjanoshikOpen certificate NAD 500mg
PT-141 10mgNot measured
99.3%
Meets 98%
0.70% not itemisedjanoshikOpen certificate PT-141 10mg
Selank 10mgNot measured
99.9%
Meets 98%
0.10% not itemisedjanoshikOpen certificate Selank 10mg
Semax 10mgNot measured
98.1%
Meets 98%
1.90% not itemisedjanoshikOpen certificate Semax 10mg
Semax 5mgNot measured
98.2%
Meets 98%
1.80% not itemisedjanoshikOpen certificate Semax 5mg
TB500 10mgNot measured
98.8%
Meets 98%
1.20% not itemisedjanoshikOpen certificate TB500 10mg
Thymosin Alpha-1 10mgNot measured
99.1%
Meets 98%
0.90% not itemisedjanoshikOpen certificate Thymosin Alpha-1 10mg

How this is checked

Vial content
Measured net peptide content against the size on the label. Within ±3% is on label, 3 to 10% is off label, beyond ±10% is a major deviation (under- or overfilled). When a certificate weighs several vials of the batch, the vial farthest from the label is the one judged, and with several purity results the lowest counts. Blends are only checked when the certificate lists each component.
Purity
HPLC purity on each certificate against the purity the supplier promises site-wide on its own website. Up to 1 point below the claim is amber, more than that is red. Only a direct promise counts (“99%+ purity guaranteed”); explanations of what purity means, one product's figure and page code are not treated as a claim. A certificate that reports only a bound (“>99%”) is judged only when the bound meets the claim, and a specification line is never read as a result.
Whose certificate
A certificate is only read once our client-identity review has looked at it, and one issued to a different company is left out, whether the automatic check or a manual review found it. A certificate issued to the company that runs the supplier's own website counts as the supplier's. A file hosted on another supplier's website is not counted for this one. The same rules decide which certificates appear on supplier and product pages. Only peptide certificates are read: bacteriostatic water, acetic acid and other diluents are left out, and so are product data sheets, which state a specification rather than a batch result.
Main impurity
Shown when the certificate itemises it: a named impurity (TFA, deletion sequence, oxidation…) or the largest secondary peak in the HPLC peak table. Most certificates report only a purity figure, so the rest of the sample is not itemised.
Trust Score
These checks are 10 of the 25 Transparency points: vial content 7 (full credit within ±3%, half up to ±10%, none beyond, over- and underfilled alike), purity 3 (98% is the bar when a supplier advertises no figure). Fewer than 5 readable results gives half credit rather than a guess.
Source and limits
These are the supplier's own published certificates, read automatically from the PDF or image. Janoshik results tables are read twice from the image, cell by cell, and a figure the two readings disagree on is left out rather than guessed. A certificate covers one batch on one date. We have not tested these batches ourselves.

Peptide Clyde supplier page and all suppliers on Claims vs COA