PeptideScanner
Peptide Scanner does not sell peptides. Independent, not affiliated with any supplier. Disclaimer

Peptide Tech UAE: claims vs COA

The purity Peptide Tech UAE advertises and the vial sizes on its labels, checked against the 20 certificates of analysis it publishes.

No site-wide purity promise found on the website. Vial content is still checked against the label.

certificates read
20
vials outside ±3% of label
9 / 9
beyond ±10% (major)
4
below advertised purity
None

On label, within ±3%Off label, 3 to 10%Major, beyond ±10%How this is checked

Peptide Tech UAE certificates: label against measured content and purity
ProductLabel to measuredPurityMain impurityLabCOA
BPC-157 10mg
10mg → 12.42mg
Overfilled +24.2%
99.455%
0.55% not itemisedjanoshikOpen certificate BPC-157 10mg
GHK-CU 50mg
50mg → 62.1mg
Overfilled +24.2%
99.786%
0.21% not itemisedjanoshikOpen certificate GHK-CU 50mg
Retatrutide 20MG
20mg → 22.28mg
Overfilled +11.4%
99.776%
0.22% not itemisedjanoshikOpen certificate Retatrutide 20MG
TB500 10mg
10mg → 11.22mg
Overfilled +12.2%
99.614%
0.39% not itemisedjanoshikOpen certificate TB500 10mg
10mg
10mg → 9.46mg
Under label -5.4%
99.695%
0.31% not itemisedjanoshikOpen certificate 10mg
MOTS-C 10mg
10mg → 10.44mg
Over label +4.4%
99.015%
0.98% not itemisedjanoshikOpen certificate MOTS-C 10mg
Retatrutide 10MG
10mg → 10.82mg
Over label +8.2%
99.785%
0.22% not itemisedjanoshikOpen certificate Retatrutide 10MG
Retatrutide 10mg
10mg → 10.73mg
Over label +7.3%
99.46%
0.54% not itemisedjanoshikOpen certificate Retatrutide 10mg
Tesamorelin 10mg
10mg → 10.91mg
Over label +9.1%
99.482%
0.52% not itemisedjanoshikOpen certificate Tesamorelin 10mg
BPC-157
— → 10.99mg
Not checked
99.484%
0.52% not itemisedjanoshikOpen certificate BPC-157
CJC 1295 No DAC
— → 5.55mg
Not checked
99.598%
0.40% not itemisedjanoshikOpen certificate CJC 1295 No DAC
DSIP
— → 10.83mg
Not checked
99.114%
0.89% not itemisedjanoshikOpen certificate DSIP
GHK CUBlend, per-component content not listed
99.149%
0.85% not itemisedjanoshikOpen certificate GHK CU
MOTS C
— → 10.87mg
Not checked
99.089%
0.91% not itemisedjanoshikOpen certificate MOTS C
SS31
— → 7.96mg
Not checked
99.89%
0.11% not itemisedjanoshikOpen certificate SS31
Selank
— → 9.9mg
Not checked
99.31%
0.69% not itemisedjanoshikOpen certificate Selank
Semax
— → 10.84mg
Not checked
99.526%
0.47% not itemisedjanoshikOpen certificate Semax
TB500
— → 10.17mg
Not checked
99.029%
0.97% not itemisedjanoshikOpen certificate TB500
Thymosin Alpha - 1
— → 10.76mg
Not checked
99.599%
0.40% not itemisedjanoshikOpen certificate Thymosin Alpha - 1
pamorelin
— → 9.09mg
Not checked
99.73%
0.27% not itemisedjanoshikOpen certificate pamorelin

How this is checked

Vial content
Measured net peptide content against the size on the label. Within ±3% is on label, 3 to 10% is off label, beyond ±10% is a major deviation (under- or overfilled). When a certificate weighs several vials of the batch, the vial farthest from the label is the one judged, and with several purity results the lowest counts. Blends are only checked when the certificate lists each component.
Purity
HPLC purity on each certificate against the purity the supplier promises site-wide on its own website. Up to 1 point below the claim is amber, more than that is red. Only a direct promise counts (“99%+ purity guaranteed”); explanations of what purity means, one product's figure and page code are not treated as a claim. A certificate that reports only a bound (“>99%”) is judged only when the bound meets the claim, and a specification line is never read as a result.
Whose certificate
A certificate is only read once our client-identity review has looked at it, and one issued to a different company is left out, whether the automatic check or a manual review found it. A certificate issued to the company that runs the supplier's own website counts as the supplier's. A file hosted on another supplier's website is not counted for this one. The same rules decide which certificates appear on supplier and product pages. Only peptide certificates are read: bacteriostatic water, acetic acid and other diluents are left out, and so are product data sheets, which state a specification rather than a batch result.
Main impurity
Shown when the certificate itemises it: a named impurity (TFA, deletion sequence, oxidation…) or the largest secondary peak in the HPLC peak table. Most certificates report only a purity figure, so the rest of the sample is not itemised.
Trust Score
These checks are 10 of the 25 Transparency points: vial content 7 (full credit within ±3%, half up to ±10%, none beyond, over- and underfilled alike), purity 3 (98% is the bar when a supplier advertises no figure). Fewer than 5 readable results gives half credit rather than a guess.
Source and limits
These are the supplier's own published certificates, read automatically from the PDF or image. Janoshik results tables are read twice from the image, cell by cell, and a figure the two readings disagree on is left out rather than guessed. A certificate covers one batch on one date. We have not tested these batches ourselves.

Peptide Tech UAE supplier page and all suppliers on Claims vs COA