Peptide Kliniek: claims vs COA

No site-wide purity promise found on the website. Vial content is still checked against the label.
35
certificates read
0 / 0
vials outside ±3% of label
0
beyond ±10% (major)
—
below advertised purity
ProductLabel → measuredPurityMain impurityLabCOA
5-Amino-1mqNot measured
99.736%
0.26% not itemised—Open
AOD9604Not measured
99.866%
0.13% not itemised—Open
AdamaxNot measured
99.857%
0.14% not itemised—Open
BPC 157 + TB500Blend, per-component content not listed
99.759%
0.24% not itemised—Open
BPC-157Not measured
99.687%
0.31% not itemised—Open
BPC-157Not measured
99.687%
0.31% not itemised—Open
BPC-157Not measured
99.783%
0.22% not itemised—Open
CJC 1295 without dacNot measured
99.873%
0.13% not itemised—Open
CJC 1295 without dac + IpamorelinBlend, per-component content not listed
99.633%
0.37% not itemised—Open
DSIPNot measured
99.721%
0.28% not itemised—Open
EpithalonNot measured
99.638%
0.36% not itemised—Open
GHK-CUNot measured
99.856%
0.14% not itemised—Open
GHK-CUNot measured
99.873%
0.13% not itemised—Open
GHRP-2 AcetateNot measured
99.723%
0.28% not itemised—Open
GHRP-6 AcetateNot measured
99.758%
0.24% not itemised—Open
HGH Fragment 176-191Not measured
99.625%
0.38% not itemised—Open
IpamorelinNot measured
99.798%
0.20% not itemised—Open
KLOWBlend, per-component content not listed
99.792%
0.21% not itemised—Open
KPVNot measured
99.823%
0.18% not itemised—Open
Kisspeptin-10Not measured
99.812%
0.19% not itemised—Open
LL-37Not measured
99.677%
0.32% not itemised—Open
MOTS-CNot measured
99.811%
0.19% not itemised—Open
MOTS-CNot measured
99.884%
0.12% not itemised—Open
MT-2Not measured
99.803%
0.20% not itemised—Open
NAD+Not measured
99.845%
0.16% not itemised—Open
PT-141Not measured
99.798%
0.20% not itemised—Open
RetatrutideNot measured
99.827%
0.17% not itemised—Open
RetatrutideNot measured
99.782%
0.22% not itemised—Open
RetatrutideNot measured
99.889%
0.11% not itemised—Open
SS-31Not measured
99.873%
0.13% not itemised—Open
SelankNot measured
99.587%
0.41% not itemised—Open
SemaxNot measured
99.803%
0.20% not itemised—Open
TB500 - TB4Not measured
99.815%
0.19% not itemised—Open
TesamorelinNot measured
99.698%
0.30% not itemised—Open
Thymosin Alpha 1Not measured
99.877%
0.12% not itemised—Open

How this is checked

  • Vial content. Measured net peptide content against the size on the label. Within ±3% is on label, 3–10% is off label, beyond ±10% is a major deviation (under- or overfilled). When a certificate weighs several vials of the batch, the vial farthest from the label is the one judged, and with several purity results the lowest counts. Blends are only checked when the certificate lists each component.
  • Purity. HPLC purity on each certificate against the purity the supplier promises site-wide on its own website. Up to 1 point below the claim is amber, more than that is red. Only a direct promise counts (“99%+ purity guaranteed”); explanations of what purity means, one product's figure and page code are not treated as a claim. A certificate that reports only a bound (“>99%”) is judged only when the bound meets the claim, and a specification line is never read as a result.
  • Whose certificate. A certificate is only read once our client-identity review has looked at it, and one issued to a different company is left out — whether the automatic check or a manual review found it. A certificate issued to the company that runs the supplier's own website counts as the supplier's. A file hosted on another supplier's website is not counted for this one. The same rules decide which certificates appear on supplier and product pages. Only peptide certificates are read: bacteriostatic water, acetic acid and other diluents are left out, and so are product data sheets, which state a specification rather than a batch result.
  • Main impurity. Shown when the certificate itemises it: a named impurity (TFA, deletion sequence, oxidation…) or the largest secondary peak in the HPLC peak table. Most certificates report only a purity figure, so the rest of the sample is not itemised.
  • Trust Score. These checks are 10 of the 25 Transparency points: vial content 7 (full credit within ±3%, half up to ±10%, none beyond, over- and underfilled alike), purity 3 (98% is the bar when a supplier advertises no figure). Fewer than 5 readable results gives half credit rather than a guess.
  • These are the supplier's own published certificates, read automatically from the PDF or image. Janoshik results tables are read twice from the image, cell by cell, and a figure the two readings disagree on is left out rather than guessed. A certificate covers one batch on one date. We have not tested these batches ourselves.

Peptide Kliniek supplier page

Peptide Scanner is an independent aggregator. All content is for research purposes only. We do not sell, ship, or endorse any product. Read full disclaimer →