No site-wide purity promise found on the website. Vial content is still checked against the label.
- certificates read
- 12
- vials outside ±3% of label
- 9 / 12
- beyond ±10% (major)
- 3
- below advertised purity
- None
On label, within ±3%Off label, 3 to 10%Major, beyond ±10%How this is checked
| Product | Label to measured | Purity | Main impurity | Lab | COA |
|---|---|---|---|---|---|
| 5 Amino 10mg | 10mg → 12.1mg Overfilled +21.0% | 99.8% | 0.20% not itemised | freedom-diagnostics | Open certificate 5 Amino 10mg |
| AOD 5mg | 5mg → 5.26mg Over label +5.2% | 99.64% | 0.36% not itemised | freedom-diagnostics | Open certificate AOD 5mg |
| Cagrilintide 5mg | 5mg → 4.74mg Under label -5.2% | 99.86% | 0.14% not itemised | freedom-diagnostics | Open certificate Cagrilintide 5mg |
| Epithalon 10mg | 10mg → 10.02mg On label +0.2% | 99.67% | 0.33% not itemised | freedom-diagnostics | Open certificate Epithalon 10mg |
| GHK-CU 50mg | 50mg → 47.29mg Under label -5.4% | 99.31% | 0.69% not itemised | freedom-diagnostics | Open certificate GHK-CU 50mg |
| Glutathione 1500 | 1500mg → 1564.68mg Over label +4.3% | 99.82% | 0.18% not itemised | freedom-diagnostics | Open certificate Glutathione 1500 |
| Glutathione 600 | 600mg → 588.63mg On label -1.9% | 99.44% | 0.56% not itemised | freedom-diagnostics | Open certificate Glutathione 600 |
| Kisspeptin 10 5mg | 5mg → 5.36mg Over label +7.2% | 99.17% | 0.83% not itemised | freedom-diagnostics | Open certificate Kisspeptin 10 5mg |
| MT2 10mg | 10mg → 9.32mg Under label -6.8% | 99.95% | 0.05% not itemised | freedom-diagnostics | Open certificate MT2 10mg |
| NAD+ 500mg | 500mg → 313.3mg Underfilled -37.3% | 99.72% | 0.28% not itemised | freedom-diagnostics | Open certificate NAD+ 500mg |
| Tesamorelin 10mg | 10mg → 10.14mg On label +1.4% | 99.75% | 0.25% not itemised | freedom-diagnostics | Open certificate Tesamorelin 10mg |
| Tesamorelin 20mg | 20mg → 22.64mg Overfilled +13.2% | 99.74% | 0.26% not itemised | freedom-diagnostics | Open certificate Tesamorelin 20mg |
How this is checked
- Vial content
- Measured net peptide content against the size on the label. Within ±3% is on label, 3 to 10% is off label, beyond ±10% is a major deviation (under- or overfilled). When a certificate weighs several vials of the batch, the vial farthest from the label is the one judged, and with several purity results the lowest counts. Blends are only checked when the certificate lists each component.
- Purity
- HPLC purity on each certificate against the purity the supplier promises site-wide on its own website. Up to 1 point below the claim is amber, more than that is red. Only a direct promise counts (“99%+ purity guaranteed”); explanations of what purity means, one product's figure and page code are not treated as a claim. A certificate that reports only a bound (“>99%”) is judged only when the bound meets the claim, and a specification line is never read as a result.
- Whose certificate
- A certificate is only read once our client-identity review has looked at it, and one issued to a different company is left out, whether the automatic check or a manual review found it. A certificate issued to the company that runs the supplier's own website counts as the supplier's. A file hosted on another supplier's website is not counted for this one. The same rules decide which certificates appear on supplier and product pages. Only peptide certificates are read: bacteriostatic water, acetic acid and other diluents are left out, and so are product data sheets, which state a specification rather than a batch result.
- Main impurity
- Shown when the certificate itemises it: a named impurity (TFA, deletion sequence, oxidation…) or the largest secondary peak in the HPLC peak table. Most certificates report only a purity figure, so the rest of the sample is not itemised.
- Trust Score
- These checks are 10 of the 25 Transparency points: vial content 7 (full credit within ±3%, half up to ±10%, none beyond, over- and underfilled alike), purity 3 (98% is the bar when a supplier advertises no figure). Fewer than 5 readable results gives half credit rather than a guess.
- Source and limits
- These are the supplier's own published certificates, read automatically from the PDF or image. Janoshik results tables are read twice from the image, cell by cell, and a figure the two readings disagree on is left out rather than guessed. A certificate covers one batch on one date. We have not tested these batches ourselves.