PeptideScanner
Peptide Scanner does not sell peptides. Independent, not affiliated with any supplier. Disclaimer

Particle Peptides: claims vs COA

The purity Particle Peptides advertises and the vial sizes on its labels, checked against the 19 certificates of analysis it publishes.

No site-wide purity promise found on the website. Vial content is still checked against the label.

certificates read
19
vials outside ±3% of label
15 / 18
beyond ±10% (major)
6
below advertised purity
None

On label, within ±3%Off label, 3 to 10%Major, beyond ±10%How this is checked

Particle Peptides certificates: label against measured content and purity
ProductLabel to measuredPurityMain impurityLabCOA
Cartalax 20 mg
20mg → 23mg
Overfilled +15.0%
99.5%
0.50% not itemisedliquilabsOpen certificate Cartalax 20 mg
Epithalon 10 mg
10mg → 11.02mg
Overfilled +10.2%
99.3%
0.70% not itemisedliquilabsOpen certificate Epithalon 10 mg
GLP-3 10 mg
10mg → 8.61mg
Underfilled -13.9%
>99.8%
under 0.20% not itemisedliquilabsOpen certificate GLP-3 10 mg
Ipamorelin 5 mg
5mg → 6.25mg
Overfilled +25.0%
99.4%
0.60% not itemisedliquilabsOpen certificate Ipamorelin 5 mg
Selank 10 mg
10mg → 12.63mg
Overfilled +26.3%
99.7%
0.30% not itemisedliquilabsOpen certificate Selank 10 mg
Selank 10 mg
10mg → 12.01mg
Overfilled +20.1%
>99.8%
under 0.20% not itemisedliquilabsOpen certificate Selank 10 mg
AOD-9604 5 mg
5mg → 4.79mg
Under label -4.2%
>99.8%
under 0.20% not itemisedliquilabsOpen certificate AOD-9604 5 mg
BPC-157 10 mg
10mg → 10.83mg
Over label +8.3%
98.4%
1.60% not itemisedliquilabsOpen certificate BPC-157 10 mg
GHK-Cu 50 mg
50mg → 47.1mg
Under label -5.8%
99.3%
0.70% not itemisedliquilabsOpen certificate GHK-Cu 50 mg
KPV 10 mg
10mg → 10.65mg
Over label +6.5%
>99.8%
under 0.20% not itemisedliquilabsOpen certificate KPV 10 mg
KPV 5 mg
5mg → 4.64mg
Under label -7.2%
99.2%
0.80% not itemisedliquilabsOpen certificate KPV 5 mg
Modified GRF 1-29 5 mg
5mg → 4.76mg
Under label -4.8%
>99.8%
under 0.20% not itemisedliquilabsOpen certificate Modified GRF 1-29 5 mg
Semax 10 mg
10mg → 9.26mg
Under label -7.4%
99.8%
0.20% not itemisedliquilabsOpen certificate Semax 10 mg
Thymosin alfa-1 10 mg
10mg → 9.29mg
Under label -7.1%
98.4%
1.60% not itemisedliquilabsOpen certificate Thymosin alfa-1 10 mg
Thymosin beta-4 10 mg
10mg → 9.27mg
Under label -7.3%
99.8%
0.20% not itemisedliquilabsOpen certificate Thymosin beta-4 10 mg
Epithalon 10 mg
10mg → 9.88mg
On label -1.2%
98.8%
1.20% not itemisedliquilabsOpen certificate Epithalon 10 mg
GHK-Cu 50 mg
50mg → 51.2mg
On label +2.4%
>99.8%
under 0.20% not itemisedliquilabsOpen certificate GHK-Cu 50 mg
Melanotan 2 10 mg
10mg → 9.94mg
On label -0.6%
>99.8%
under 0.20% not itemisedliquilabsOpen certificate Melanotan 2 10 mg
TB-500
— → 11.57mg
Not checked
99.8%
0.20% not itemisedliquilabsOpen certificate TB-500

How this is checked

Vial content
Measured net peptide content against the size on the label. Within ±3% is on label, 3 to 10% is off label, beyond ±10% is a major deviation (under- or overfilled). When a certificate weighs several vials of the batch, the vial farthest from the label is the one judged, and with several purity results the lowest counts. Blends are only checked when the certificate lists each component.
Purity
HPLC purity on each certificate against the purity the supplier promises site-wide on its own website. Up to 1 point below the claim is amber, more than that is red. Only a direct promise counts (“99%+ purity guaranteed”); explanations of what purity means, one product's figure and page code are not treated as a claim. A certificate that reports only a bound (“>99%”) is judged only when the bound meets the claim, and a specification line is never read as a result.
Whose certificate
A certificate is only read once our client-identity review has looked at it, and one issued to a different company is left out, whether the automatic check or a manual review found it. A certificate issued to the company that runs the supplier's own website counts as the supplier's. A file hosted on another supplier's website is not counted for this one. The same rules decide which certificates appear on supplier and product pages. Only peptide certificates are read: bacteriostatic water, acetic acid and other diluents are left out, and so are product data sheets, which state a specification rather than a batch result.
Main impurity
Shown when the certificate itemises it: a named impurity (TFA, deletion sequence, oxidation…) or the largest secondary peak in the HPLC peak table. Most certificates report only a purity figure, so the rest of the sample is not itemised.
Trust Score
These checks are 10 of the 25 Transparency points: vial content 7 (full credit within ±3%, half up to ±10%, none beyond, over- and underfilled alike), purity 3 (98% is the bar when a supplier advertises no figure). Fewer than 5 readable results gives half credit rather than a guess.
Source and limits
These are the supplier's own published certificates, read automatically from the PDF or image. Janoshik results tables are read twice from the image, cell by cell, and a figure the two readings disagree on is left out rather than guessed. A certificate covers one batch on one date. We have not tested these batches ourselves.

Particle Peptides supplier page and all suppliers on Claims vs COA