PeptideScanner
Peptide Scanner does not sell peptides. Independent, not affiliated with any supplier. Disclaimer

Optimum ReGen Peptides: claims vs COA

The purity Optimum ReGen Peptides advertises and the vial sizes on its labels, checked against the 26 certificates of analysis it publishes.

No site-wide purity promise found on the website. Vial content is still checked against the label.

certificates read
26
vials outside ±3% of label
20 / 21
beyond ±10% (major)
15
below advertised purity
None

On label, within ±3%Off label, 3 to 10%Major, beyond ±10%How this is checked

Optimum ReGen Peptides certificates: label against measured content and purity
ProductLabel to measuredPurityMain impurityLabCOA
5 Amino 1mq 5mg
5mg → 7.58mg
Overfilled +51.6%
99.82%
0.18% not itemisedfreedom-diagnosticsOpen certificate 5 Amino 1mq 5mg
AOD-9604 5mg
5mg → 7.13mg
Overfilled +42.6%
99.15%
0.85% not itemisedfreedom-diagnosticsOpen certificate AOD-9604 5mg
ARA-290 10mg
10mg → 11.56mg
Overfilled +15.6%
99.36%
0.64% not itemisedfreedom-diagnosticsOpen certificate ARA-290 10mg
Adamax 5mg
5mg → 6.23mg
Overfilled +24.6%
99.82%
0.18% not itemisedfreedom-diagnosticsOpen certificate Adamax 5mg
Cjc-1295 (Dac) 2mg
2mg → 2.33mg
Overfilled +16.5%
99.264%
0.74% not itemisedfreedom-diagnosticsOpen certificate Cjc-1295 (Dac) 2mg
IGF-1lr3 1mg
1mg → 1.34mg
Overfilled +34.0%
96.397%
3.60% not itemisedfreedom-diagnosticsOpen certificate IGF-1lr3 1mg
Ipamorelin 5mg
5mg → 7.25mg
Overfilled +45.0%
99.904%
0.10% not itemisedfreedom-diagnosticsOpen certificate Ipamorelin 5mg
MT-1 10mg
10mg → 11.11mg
Overfilled +11.1%
99.9%
0.10% not itemisedfreedom-diagnosticsOpen certificate MT-1 10mg
MotC 10mg
10mg → 12.2mg
Overfilled +22.0%
99.001%
1.00% not itemisedfreedom-diagnosticsOpen certificate MotC 10mg
Reta 10mg
10mg → 11.46mg
Overfilled +14.6%
99.84%
0.16% not itemisedfreedom-diagnosticsOpen certificate Reta 10mg
Reta 30mg
30mg → 37.08mg
Overfilled +23.6%
99.614%
0.39% not itemisedfreedom-diagnosticsOpen certificate Reta 30mg
SS-31 10mg
10mg → 11.39mg
Overfilled +13.9%
99.85%
0.15% not itemisedfreedom-diagnosticsOpen certificate SS-31 10mg
Selank 10mg
10mg → 11.39mg
Overfilled +13.9%
99.87%
0.13% not itemisedfreedom-diagnosticsOpen certificate Selank 10mg
Semax 10mg
10mg → 12.54mg
Overfilled +25.4%
99.65%
0.35% not itemisedfreedom-diagnosticsOpen certificate Semax 10mg
Tesamorelin 10mg
10mg → 13.21mg
Overfilled +32.1%
99.204%
0.80% not itemisedfreedom-diagnosticsOpen certificate Tesamorelin 10mg
CJC 1296 5mg (No DAC)
5mg → 5.35mg
Over label +7.0%
99.76%
0.24% not itemisedfreedom-diagnosticsOpen certificate CJC 1296 5mg (No DAC)
GHK-cu 50mg
50mg → 52.47mg
Over label +4.9%
99.31%
0.69% not itemisedfreedom-diagnosticsOpen certificate GHK-cu 50mg
Glutathione 500mg
500mg → 529.56mg
Over label +5.9%
99.43%
0.57% not itemisedfreedom-diagnosticsOpen certificate Glutathione 500mg
KPV 10mg
10mg → 10.55mg
Over label +5.5%
99.78%
0.22% not itemisedfreedom-diagnosticsOpen certificate KPV 10mg
PT-141 10mg
10mg → 9.62mg
Under label -3.8%
99.77%
0.23% not itemisedfreedom-diagnosticsOpen certificate PT-141 10mg
Bpc157/Tb500 10mgBlend, per-component content not listed
99.34%
0.66% not itemisedfreedom-diagnosticsOpen certificate Bpc157/Tb500 10mg
CJC-1295 (no DAC)/Ipamorelin 10mgBlend, per-component content not listed
99.85%
0.15% not itemisedfreedom-diagnosticsOpen certificate CJC-1295 (no DAC)/Ipamorelin 10mg
KLOW 80mgBlend, per-component content not listed
99.87%
0.13% not itemisedfreedom-diagnosticsOpen certificate KLOW 80mg
KLOW 80mgBlend, per-component content not listed
99.87%
0.13% not itemisedfreedom-diagnosticsOpen certificate KLOW 80mg
NAD + 500
— → 519.26mg
Not checked
99.528%
0.47% not itemisedfreedom-diagnosticsOpen certificate NAD + 500
Tirzepatide 30mg
30mg → 30.52mg
On label +1.7%
99.61%
0.39% not itemisedfreedom-diagnosticsOpen certificate Tirzepatide 30mg

How this is checked

Vial content
Measured net peptide content against the size on the label. Within ±3% is on label, 3 to 10% is off label, beyond ±10% is a major deviation (under- or overfilled). When a certificate weighs several vials of the batch, the vial farthest from the label is the one judged, and with several purity results the lowest counts. Blends are only checked when the certificate lists each component.
Purity
HPLC purity on each certificate against the purity the supplier promises site-wide on its own website. Up to 1 point below the claim is amber, more than that is red. Only a direct promise counts (“99%+ purity guaranteed”); explanations of what purity means, one product's figure and page code are not treated as a claim. A certificate that reports only a bound (“>99%”) is judged only when the bound meets the claim, and a specification line is never read as a result.
Whose certificate
A certificate is only read once our client-identity review has looked at it, and one issued to a different company is left out, whether the automatic check or a manual review found it. A certificate issued to the company that runs the supplier's own website counts as the supplier's. A file hosted on another supplier's website is not counted for this one. The same rules decide which certificates appear on supplier and product pages. Only peptide certificates are read: bacteriostatic water, acetic acid and other diluents are left out, and so are product data sheets, which state a specification rather than a batch result.
Main impurity
Shown when the certificate itemises it: a named impurity (TFA, deletion sequence, oxidation…) or the largest secondary peak in the HPLC peak table. Most certificates report only a purity figure, so the rest of the sample is not itemised.
Trust Score
These checks are 10 of the 25 Transparency points: vial content 7 (full credit within ±3%, half up to ±10%, none beyond, over- and underfilled alike), purity 3 (98% is the bar when a supplier advertises no figure). Fewer than 5 readable results gives half credit rather than a guess.
Source and limits
These are the supplier's own published certificates, read automatically from the PDF or image. Janoshik results tables are read twice from the image, cell by cell, and a figure the two readings disagree on is left out rather than guessed. A certificate covers one batch on one date. We have not tested these batches ourselves.

Optimum ReGen Peptides supplier page and all suppliers on Claims vs COA