PeptideScanner
Peptide Scanner does not sell peptides. Independent, not affiliated with any supplier. Disclaimer

NuVion Health: claims vs COA

The purity NuVion Health advertises and the vial sizes on its labels, checked against the 17 certificates of analysis it publishes.

No site-wide purity promise found on the website. Vial content is still checked against the label.

certificates read
17
vials outside ±3% of label
6 / 7
beyond ±10% (major)
6
below advertised purity
None

On label, within ±3%Off label, 3 to 10%Major, beyond ±10%How this is checked

NuVion Health certificates: label against measured content and purity
ProductLabel to measuredPurityMain impurityLabCOA
Bronchogen 20mg
20mg → 22.08mg
Overfilled +10.4%
99.766%
0.23% not itemisedjanoshikOpen certificate Bronchogen 20mg
FOX04 10mg
10mg → 11.97mg
Overfilled +19.7%
99.785%
0.22% not itemisedjanoshikOpen certificate FOX04 10mg
P21 10mg
10mg → 12.13mg
Overfilled +21.3%
99.437%
0.56% not itemisedjanoshikOpen certificate P21 10mg
Vip 10mg
10mg → 11.61mg
Overfilled +16.1%
99.506%
0.49% not itemisedjanoshikOpen certificate Vip 10mg
ghrp-2 10mg
10mg → 11.16mg
Overfilled +11.6%
99.216%
0.78% not itemisedjanoshikOpen certificate ghrp-2 10mg
tesa 10mg
10mg → 11.6mg
Overfilled +16.0%
99.676%
0.32% not itemisedjanoshikOpen certificate tesa 10mg
BPC 157
— → 9.08mg
Not checked
98.081%
1.92% not itemisedjanoshikOpen certificate BPC 157
CJC1295-No DAC
— → 4.92mg
Not checked
99.46%
0.54% not itemisedjanoshikOpen certificate CJC1295-No DAC
Cagrilintide 10m
— → 11.97mg
Not checked
99.939%
0.06% not itemisedjanoshikOpen certificate Cagrilintide 10m
Cardiogen 20mgNot measured
99.438%
0.56% not itemisedjanoshikOpen certificate Cardiogen 20mg
DSIP
— → 12.36mg
Not checked
99.671%
0.33% not itemisedjanoshikOpen certificate DSIP
GHK-Cu
— → 41.4mg
Not checked
99.713%
0.29% not itemisedjanoshikOpen certificate GHK-Cu
LL37 5m¢
— → 5.92mg
Not checked
99.85%
0.15% not itemisedjanoshikOpen certificate LL37 5m¢
PE 22-28 10mg
10mg → 9.91mg
On label -0.9%
99.861%
0.14% not itemisedjanoshikOpen certificate PE 22-28 10mg
Retatutide
— → 9.93mg
Not checked
99.22%
0.78% not itemisedjanoshikOpen certificate Retatutide
TB-500
— → 10.33mg
Not checked
99.914%
0.09% not itemisedjanoshikOpen certificate TB-500
pamorelin
— → 8.99mg
Not checked
99.708%
0.29% not itemisedjanoshikOpen certificate pamorelin

How this is checked

Vial content
Measured net peptide content against the size on the label. Within ±3% is on label, 3 to 10% is off label, beyond ±10% is a major deviation (under- or overfilled). When a certificate weighs several vials of the batch, the vial farthest from the label is the one judged, and with several purity results the lowest counts. Blends are only checked when the certificate lists each component.
Purity
HPLC purity on each certificate against the purity the supplier promises site-wide on its own website. Up to 1 point below the claim is amber, more than that is red. Only a direct promise counts (“99%+ purity guaranteed”); explanations of what purity means, one product's figure and page code are not treated as a claim. A certificate that reports only a bound (“>99%”) is judged only when the bound meets the claim, and a specification line is never read as a result.
Whose certificate
A certificate is only read once our client-identity review has looked at it, and one issued to a different company is left out, whether the automatic check or a manual review found it. A certificate issued to the company that runs the supplier's own website counts as the supplier's. A file hosted on another supplier's website is not counted for this one. The same rules decide which certificates appear on supplier and product pages. Only peptide certificates are read: bacteriostatic water, acetic acid and other diluents are left out, and so are product data sheets, which state a specification rather than a batch result.
Main impurity
Shown when the certificate itemises it: a named impurity (TFA, deletion sequence, oxidation…) or the largest secondary peak in the HPLC peak table. Most certificates report only a purity figure, so the rest of the sample is not itemised.
Trust Score
These checks are 10 of the 25 Transparency points: vial content 7 (full credit within ±3%, half up to ±10%, none beyond, over- and underfilled alike), purity 3 (98% is the bar when a supplier advertises no figure). Fewer than 5 readable results gives half credit rather than a guess.
Source and limits
These are the supplier's own published certificates, read automatically from the PDF or image. Janoshik results tables are read twice from the image, cell by cell, and a figure the two readings disagree on is left out rather than guessed. A certificate covers one batch on one date. We have not tested these batches ourselves.

NuVion Health supplier page and all suppliers on Claims vs COA