Website claim: 99% purity. “…s for advanced research. Purity. Transparency. Reliability. ≥99% PURITY GUARANTEED INDEPENDENTLY LAB TESTED FAST & DISCREET SHIPPIN…” Source (read 2026-09-25)
23
certificates read
1 / 2
vials outside ±3% of label
0
beyond ±10% (major)
1 / 16
below advertised purity
ProductLabel → measuredPurityMain impurityLabCOA
BPC-157 BPC-157 ER
10mg → 10.5mg
Over label +5.0%
>90%
under 10.00% not itemisedhorizon-analyticalOpen
MOTS-c MoTs-< EeeNot measured
98%
1.00 pts below 99%
2.00% not itemisedhorizon-analyticalOpen
GLOW-COA-TB500.pngBlend, per-component content not listed
99.64%
Meets 99%
0.36% not itemised—Open
MOTS-COA.pngNot measured
99.86%
Meets 99%
0.14% not itemised—Open
Retatrutide-COA.pngNot measured
99.89%
Meets 99%
0.11% not itemised—Open
Screenshot-2025-12-28-at-10.49.22-PM.pngNot measured
99.35%
Meets 99%
0.65% not itemisedfreedom-diagnosticsOpen
Screenshot-2025-12-28-at-10.50.16-PM.pngNot measured
99.843%
Meets 99%
0.16% not itemisedfreedom-diagnosticsOpen
Screenshot-2025-12-28-at-10.50.59-PM.pngNot measured
99.072%
Meets 99%
0.93% not itemisedfreedom-diagnosticsOpen
Tesamorelin-COA.pngNot measured
99.89%
Meets 99%
0.11% not itemised—Open
Tirzepatide-COA.pngNot measured
99.9%
Meets 99%
0.10% not itemised—Open
Screenshot-2026-06-01-at-9.10.12-AM.pngNot measured
>98%
under 2.00% not itemisedhorizon-analyticalOpen
GHK-Cu cHK-Cu EeeNot measured
99.6%
Meets 99%
0.40% not itemisedhorizon-analyticalOpen
IpamorelinNot measured
>98%
under 2.00% not itemisedhorizon-analyticalOpen
NAD+ NAD+ EeeNot measured
99.49%
Meets 99%
0.51% not itemisedhorizon-analyticalOpen
OxytocinNot measured
>98%
under 2.00% not itemisedhorizon-analyticalOpen
PraNot measured
99.36%
Meets 99%
0.64% not itemisedhorizon-analyticalOpen
SelankNot measured
>98%
under 2.00% not itemisedhorizon-analyticalOpen
Semaglutide Semaglutide io}
10mg → 10.12mg
On label +1.2%
99.23%
Meets 99%
0.77% not itemisedhorizon-analyticalOpen
Semaglutide ‘Semaglutide PRENot measured
99.23%
Meets 99%
0.77% not itemisedhorizon-analyticalOpen
Semax ‘Semax EeeNot measured
>98%
under 2.00% not itemisedhorizon-analyticalOpen
Tesamorelin
10mg → 18mg
Not checked
99.23%
Meets 99%
0.77% not itemisedhorizon-analyticalOpen
Thymosin Alpha-t Thymosin Alpha-t ERENot measured
99.32%
Meets 99%
0.68% not itemisedhorizon-analyticalOpen
Tirzepatide Cores 2025788-19-2
10mg → 101mg
Not checked
——horizon-analyticalOpen

How this is checked

  • Vial content. Measured net peptide content against the size on the label. Within ±3% is on label, 3–10% is off label, beyond ±10% is a major deviation (under- or overfilled). When a certificate weighs several vials of the batch, the vial farthest from the label is the one judged, and with several purity results the lowest counts. Blends are only checked when the certificate lists each component.
  • Purity. HPLC purity on each certificate against the purity the supplier promises site-wide on its own website. Up to 1 point below the claim is amber, more than that is red. Only a direct promise counts (“99%+ purity guaranteed”); explanations of what purity means, one product's figure and page code are not treated as a claim. A certificate that reports only a bound (“>99%”) is judged only when the bound meets the claim, and a specification line is never read as a result.
  • Whose certificate. A certificate is only read once our client-identity review has looked at it, and one issued to a different company is left out — whether the automatic check or a manual review found it. A certificate issued to the company that runs the supplier's own website counts as the supplier's. A file hosted on another supplier's website is not counted for this one. The same rules decide which certificates appear on supplier and product pages. Only peptide certificates are read: bacteriostatic water, acetic acid and other diluents are left out, and so are product data sheets, which state a specification rather than a batch result.
  • Main impurity. Shown when the certificate itemises it: a named impurity (TFA, deletion sequence, oxidation…) or the largest secondary peak in the HPLC peak table. Most certificates report only a purity figure, so the rest of the sample is not itemised.
  • Trust Score. These checks are 10 of the 25 Transparency points: vial content 7 (full credit within ±3%, half up to ±10%, none beyond, over- and underfilled alike), purity 3 (98% is the bar when a supplier advertises no figure). Fewer than 5 readable results gives half credit rather than a guess.
  • These are the supplier's own published certificates, read automatically from the PDF or image. Janoshik results tables are read twice from the image, cell by cell, and a figure the two readings disagree on is left out rather than guessed. A certificate covers one batch on one date. We have not tested these batches ourselves.