PeptideScanner
Peptide Scanner does not sell peptides. Independent, not affiliated with any supplier. Disclaimer

NuMe Peptides: claims vs COA

The purity NuMe Peptides advertises and the vial sizes on its labels, checked against the 21 certificates of analysis it publishes.

No site-wide purity promise found on the website. Vial content is still checked against the label.

certificates read
21
vials outside ±3% of label
0 / 0
beyond ±10% (major)
0
below advertised purity
None

On label, within ±3%Off label, 3 to 10%Major, beyond ±10%How this is checked

NuMe Peptides certificates: label against measured content and purity
ProductLabel to measuredPurityMain impurityLabCOA
5-Amino-1MQNot measured
99.759%
0.24% not itemisedaccumark-labsOpen certificate 5-Amino-1MQ
BPC-157Not measured
99.546%
0.45% not itemisedaccumark-labsOpen certificate BPC-157
CJC-1295 (no DAC)Not measured
99.931%
0.07% not itemisedaccumark-labsOpen certificate CJC-1295 (no DAC)
CJC-1295 (no DAC), IpamorelinBlend, per-component content not listed
99.74%
0.26% not itemisedaccumark-labsOpen certificate CJC-1295 (no DAC), Ipamorelin
CagrilintideNot measured
99.864%
0.14% not itemisedaccumark-labsOpen certificate Cagrilintide
EpitalonNot measured
99.163%
0.84% not itemisedaccumark-labsOpen certificate Epitalon
GHK-CuNot measured
99.903%
0.10% not itemisedaccumark-labsOpen certificate GHK-Cu
GHRP-6Not measured
99.698%
0.30% not itemisedaccumark-labsOpen certificate GHRP-6
IpamorelinNot measured
99.619%
0.38% not itemisedaccumark-labsOpen certificate Ipamorelin
Kisspeptin-10Not measured
99.064%
0.94% not itemisedaccumark-labsOpen certificate Kisspeptin-10
MOTS-cNot measured
99.778%
0.22% not itemisedaccumark-labsOpen certificate MOTS-c
Melanotan IINot measured
99.862%
0.14% not itemisedaccumark-labsOpen certificate Melanotan II
NAD+Not measured
99.97%
0.03% not itemisedaccumark-labsOpen certificate NAD+
PT-141Not measured
99.933%
0.07% not itemisedaccumark-labsOpen certificate PT-141
SelankNot measured
99.874%
0.13% not itemisedaccumark-labsOpen certificate Selank
SemaxNot measured
99.906%
0.09% not itemisedaccumark-labsOpen certificate Semax
SermorelinNot measured
99.78%
0.22% not itemisedaccumark-labsOpen certificate Sermorelin
TB500 (17-23 Fragment)Not measured
99.658%
0.34% not itemisedaccumark-labsOpen certificate TB500 (17-23 Fragment)
Thymosin Alpha-1Not measured
99.269%
0.73% not itemisedaccumark-labsOpen certificate Thymosin Alpha-1
Thymosin Beta 4)Not measured
99.86%
0.14% not itemisedaccumark-labsOpen certificate Thymosin Beta 4)
cagrilintideNot measured
99%
1.00% not itemisedUnknownOpen certificate cagrilintide

How this is checked

Vial content
Measured net peptide content against the size on the label. Within ±3% is on label, 3 to 10% is off label, beyond ±10% is a major deviation (under- or overfilled). When a certificate weighs several vials of the batch, the vial farthest from the label is the one judged, and with several purity results the lowest counts. Blends are only checked when the certificate lists each component.
Purity
HPLC purity on each certificate against the purity the supplier promises site-wide on its own website. Up to 1 point below the claim is amber, more than that is red. Only a direct promise counts (“99%+ purity guaranteed”); explanations of what purity means, one product's figure and page code are not treated as a claim. A certificate that reports only a bound (“>99%”) is judged only when the bound meets the claim, and a specification line is never read as a result.
Whose certificate
A certificate is only read once our client-identity review has looked at it, and one issued to a different company is left out, whether the automatic check or a manual review found it. A certificate issued to the company that runs the supplier's own website counts as the supplier's. A file hosted on another supplier's website is not counted for this one. The same rules decide which certificates appear on supplier and product pages. Only peptide certificates are read: bacteriostatic water, acetic acid and other diluents are left out, and so are product data sheets, which state a specification rather than a batch result.
Main impurity
Shown when the certificate itemises it: a named impurity (TFA, deletion sequence, oxidation…) or the largest secondary peak in the HPLC peak table. Most certificates report only a purity figure, so the rest of the sample is not itemised.
Trust Score
These checks are 10 of the 25 Transparency points: vial content 7 (full credit within ±3%, half up to ±10%, none beyond, over- and underfilled alike), purity 3 (98% is the bar when a supplier advertises no figure). Fewer than 5 readable results gives half credit rather than a guess.
Source and limits
These are the supplier's own published certificates, read automatically from the PDF or image. Janoshik results tables are read twice from the image, cell by cell, and a figure the two readings disagree on is left out rather than guessed. A certificate covers one batch on one date. We have not tested these batches ourselves.

NuMe Peptides supplier page and all suppliers on Claims vs COA