No site-wide purity promise found on the website. Vial content is still checked against the label.
- certificates read
- 28
- vials outside ±3% of label
- 6 / 12
- beyond ±10% (major)
- 4
- below advertised purity
- None
On label, within ±3%Off label, 3 to 10%Major, beyond ±10%How this is checked
| Product | Label to measured | Purity | Main impurity | Lab | COA |
|---|---|---|---|---|---|
| 146f0c57d1e1.png | 10mg → 11.04mg Overfilled +10.4% | 99.71% | Acetate 12% | Unknown | Open certificate 146f0c57d1e1.png |
| ce126e079b97.png | 10mg → 11.04mg Overfilled +10.4% | 99.48% | Acetate 12% | Unknown | Open certificate ce126e079b97.png |
| 9a24e982398a.png | 13mg → 14.83mg Overfilled +14.1% | 99.42% | Acetate 12% | Unknown | Open certificate 9a24e982398a.png |
| Sermorelin 10mg | 10mg → 12.23mg Overfilled +22.3% | 99.28% | 0.72% not itemised | freedom-diagnostics | Open certificate Sermorelin 10mg |
| cb5b6fd272a1.png | 50mg → 51.73mg Over label +3.5% | 99.9% | 0.10% not itemised | ils-labs | Open certificate cb5b6fd272a1.png |
| semaglutide | 10mg → 10.69mg Over label +6.9% | 99.88% | 0.12% not itemised | ils-labs | Open certificate semaglutide |
| 0daf0c4d4121.png | Not measured | 99.47% | Acetate 12% | Unknown | Open certificate 0daf0c4d4121.png |
| 5bb8dd3baa70.png | 10mg → 10.19mg On label +1.9% | 99.81% | Acetate 12% | Unknown | Open certificate 5bb8dd3baa70.png |
| 07e8845d7d90.png | Not measured | 99.87% | Acetate 12% | Unknown | Open certificate 07e8845d7d90.png |
| cb1ff0b2854a.png | 10mg → 10.18mg On label +1.8% | 99.74% | Acetate 12% | Unknown | Open certificate cb1ff0b2854a.png |
| f54b74e3fc90.png | Not measured | 99.82% | Acetate 12% | Unknown | Open certificate f54b74e3fc90.png |
| 8f2d31a192ff.png | Not measured | 99.81% | Acetate 12% | Unknown | Open certificate 8f2d31a192ff.png |
| 533d7f014bdd.png | 70mg → 71.05mg On label +1.5% | 99.86% | 0.14% not itemised | Unknown | Open certificate 533d7f014bdd.png |
| a7783514bbde.png | Not measured | 99.94% | Acetate 12% | Unknown | Open certificate a7783514bbde.png |
| c60b1fecd5ed.png | 30mg → 30.11mg On label +0.4% | 99.87% | Acetate 12% | Unknown | Open certificate c60b1fecd5ed.png |
| 9469ffadc5fd.png | Not measured | 99.9% | Acetate 12% | Unknown | Open certificate 9469ffadc5fd.png |
| a58f258c91eb.png | Not measured | 99.87% | Acetate 12% | Unknown | Open certificate a58f258c91eb.png |
| 59b4801495_image | Not measured | 99.87% | Acetate 12% | Unknown | Open certificate 59b4801495_image |
| b73f2fa51f5d.png | 80mg → 82.15mg On label +2.7% | 99.73% | 0.27% not itemised | Unknown | Open certificate b73f2fa51f5d.png |
| 91e39b94efc1.png | 10mg → 10.13mg On label +1.3% | 99.48% | Acetate 12% | Unknown | Open certificate 91e39b94efc1.png |
| ab994b71c684.png | Not measured | 99.91% | Acetate 12% | Unknown | Open certificate ab994b71c684.png |
| fa521336524b.png | Not measured | 99.79% | Acetate 12% | Unknown | Open certificate fa521336524b.png |
| 7ddf5cdef3d0.png | Not measured | 99.24% | Acetate 12% | Unknown | Open certificate 7ddf5cdef3d0.png |
| fc489199c08d.png | Not measured | 99.82% | Acetate 12% | Unknown | Open certificate fc489199c08d.png |
| 8b45e7811032.png | Not measured | 99.93% | Acetate 12% | Unknown | Open certificate 8b45e7811032.png |
| b6e514b3f56f.png | Not measured | 99.94% | Acetate 12% | Unknown | Open certificate b6e514b3f56f.png |
| BPC-157/TB-500 (Wolverine Blend) | Blend, per-component content not listed | 99.73% | Acetate 12% | Unknown | Open certificate BPC-157/TB-500 (Wolverine Blend) |
| CJC-1295 (No DAC) | — → 11.66mg Not checked | 99.42% | 0.58% not itemised | freedom-diagnostics | Open certificate CJC-1295 (No DAC) |
How this is checked
- Vial content
- Measured net peptide content against the size on the label. Within ±3% is on label, 3 to 10% is off label, beyond ±10% is a major deviation (under- or overfilled). When a certificate weighs several vials of the batch, the vial farthest from the label is the one judged, and with several purity results the lowest counts. Blends are only checked when the certificate lists each component.
- Purity
- HPLC purity on each certificate against the purity the supplier promises site-wide on its own website. Up to 1 point below the claim is amber, more than that is red. Only a direct promise counts (“99%+ purity guaranteed”); explanations of what purity means, one product's figure and page code are not treated as a claim. A certificate that reports only a bound (“>99%”) is judged only when the bound meets the claim, and a specification line is never read as a result.
- Whose certificate
- A certificate is only read once our client-identity review has looked at it, and one issued to a different company is left out, whether the automatic check or a manual review found it. A certificate issued to the company that runs the supplier's own website counts as the supplier's. A file hosted on another supplier's website is not counted for this one. The same rules decide which certificates appear on supplier and product pages. Only peptide certificates are read: bacteriostatic water, acetic acid and other diluents are left out, and so are product data sheets, which state a specification rather than a batch result.
- Main impurity
- Shown when the certificate itemises it: a named impurity (TFA, deletion sequence, oxidation…) or the largest secondary peak in the HPLC peak table. Most certificates report only a purity figure, so the rest of the sample is not itemised.
- Trust Score
- These checks are 10 of the 25 Transparency points: vial content 7 (full credit within ±3%, half up to ±10%, none beyond, over- and underfilled alike), purity 3 (98% is the bar when a supplier advertises no figure). Fewer than 5 readable results gives half credit rather than a guess.
- Source and limits
- These are the supplier's own published certificates, read automatically from the PDF or image. Janoshik results tables are read twice from the image, cell by cell, and a figure the two readings disagree on is left out rather than guessed. A certificate covers one batch on one date. We have not tested these batches ourselves.