Midwest Compounds: claims vs COA

The purity Midwest Compounds advertises and the vial sizes on its labels, checked against the 24 certificates of analysis it publishes.

No site-wide purity promise found on the website. Vial content is still checked against the label.

certificates read
24
vials outside ±3% of label
15 / 19
beyond ±10% (major)
8
below advertised purity
None

On label, within ±3%Off label, 3 to 10%Major, beyond ±10%How this is checked

Midwest Compounds certificates: label against measured content and purity
ProductLabel to measuredPurityMain impurityLabCOA
BB20Not measured
99.43%
0.57% not itemisedfreedom-diagnosticsOpen certificate BB20
BB20 20mgNot measured
99.58%
0.42% not itemisedfreedom-diagnosticsOpen certificate BB20 20mg
BPC10 10mg
10mg → 11.15mg
Overfilled +11.5%
99.83%
0.17% not itemisedfreedom-diagnosticsOpen certificate BPC10 10mg
cp10 10mgNot measured
99.9%
0.10% not itemisedfreedom-diagnosticsOpen certificate cp10 10mg
GHK-Cu 50
50mg → 54.28mg
Over label +8.6%
99.75%
0.25% not itemisedfreedom-diagnosticsOpen certificate GHK-Cu 50
GHK100mg
100mg → 102.09mg
On label +2.1%
99.98%
0.02% not itemisedfreedom-diagnosticsOpen certificate GHK100mg
Klow80 80mgNot measured
99.94%
0.06% not itemisedfreedom-diagnosticsOpen certificate Klow80 80mg
MOTS-10 10mg
10mg → 12.61mg
Overfilled +26.1%
99.27%
0.73% not itemisedfreedom-diagnosticsOpen certificate MOTS-10 10mg
ms40 40mg
40mg → 45.2mg
Overfilled +13.0%
99.58%
0.42% not itemisedfreedom-diagnosticsOpen certificate ms40 40mg
NAD 1000mg
1000mg → 1008.89mg
On label +0.9%
99.89%
0.11% not itemisedfreedom-diagnosticsOpen certificate NAD 1000mg
RT 30
30mg → 33.47mg
Overfilled +11.6%
99.92%
0.08% not itemisedfreedom-diagnosticsOpen certificate RT 30
RT 30mg
30mg → 31.03mg
Over label +3.4%
99.86%
0.14% not itemisedfreedom-diagnosticsOpen certificate RT 30mg
RT-10 10mg
10mg → 12.41mg
Overfilled +24.1%
99.68%
0.32% not itemisedfreedom-diagnosticsOpen certificate RT-10 10mg
RT-15 15mg
15mg → 16.36mg
Over label +9.1%
99.77%
0.23% not itemisedfreedom-diagnosticsOpen certificate RT-15 15mg
RT-20 20mg
20mg → 21.18mg
Over label +5.9%
99.84%
0.16% not itemisedfreedom-diagnosticsOpen certificate RT-20 20mg
RT50mg
50mg → 49.45mg
On label -1.1%
99.9%
0.10% not itemisedfreedom-diagnosticsOpen certificate RT50mg
SER10 10mgNot measured
99.63%
0.37% not itemisedfreedom-diagnosticsOpen certificate SER10 10mg
T-30 30mg
30mg → 31.71mg
Over label +5.7%
99.83%
0.17% not itemisedfreedom-diagnosticsOpen certificate T-30 30mg
T60 60mg
60mg → 58.14mg
Under label -3.1%
99.99%
0.01% not itemisedfreedom-diagnosticsOpen certificate T60 60mg
TB-10 10mg
10mg → 13.86mg
Overfilled +38.6%
99.39%
0.61% not itemisedfreedom-diagnosticsOpen certificate TB-10 10mg
TESA 10mg
10mg → 9.61mg
Under label -3.9%
99.72%
0.28% not itemisedfreedom-diagnosticsOpen certificate TESA 10mg
TR-60
60mg → 59.32mg
On label -1.1%
99.98%
0.02% not itemisedfreedom-diagnosticsOpen certificate TR-60
TSA 10
10mg → 12.4mg
Overfilled +24.0%
99.66%
0.34% not itemisedfreedom-diagnosticsOpen certificate TSA 10
TSA-10
10mg → 11.58mg
Overfilled +15.8%
99.81%
0.19% not itemisedfreedom-diagnosticsOpen certificate TSA-10

How this is checked

Vial content
Measured net peptide content against the size on the label. Within ±3% is on label, 3 to 10% is off label, beyond ±10% is a major deviation (under- or overfilled). When a certificate weighs several vials of the batch, the vial farthest from the label is the one judged, and with several purity results the lowest counts. Blends are only checked when the certificate lists each component.
Purity
HPLC purity on each certificate against the purity the supplier promises site-wide on its own website. Up to 1 point below the claim is amber, more than that is red. Only a direct promise counts (“99%+ purity guaranteed”); explanations of what purity means, one product's figure and page code are not treated as a claim. A certificate that reports only a bound (“>99%”) is judged only when the bound meets the claim, and a specification line is never read as a result.
Whose certificate
A certificate is only read once our client-identity review has looked at it, and one issued to a different company is left out, whether the automatic check or a manual review found it. A certificate issued to the company that runs the supplier's own website counts as the supplier's. A file hosted on another supplier's website is not counted for this one. The same rules decide which certificates appear on supplier and product pages. Only peptide certificates are read: bacteriostatic water, acetic acid and other diluents are left out, and so are product data sheets, which state a specification rather than a batch result.
Main impurity
Shown when the certificate itemises it: a named impurity (TFA, deletion sequence, oxidation…) or the largest secondary peak in the HPLC peak table. Most certificates report only a purity figure, so the rest of the sample is not itemised.
Trust Score
These checks are 10 of the 25 Transparency points: vial content 7 (full credit within ±3%, half up to ±10%, none beyond, over- and underfilled alike), purity 3 (98% is the bar when a supplier advertises no figure). Fewer than 5 readable results gives half credit rather than a guess.
Source and limits
These are the supplier's own published certificates, read automatically from the PDF or image. Janoshik results tables are read twice from the image, cell by cell, and a figure the two readings disagree on is left out rather than guessed. A certificate covers one batch on one date. We have not tested these batches ourselves.