Loti Labs: claims vs COA

Website claim: 99% purity. “…s HPLC Analysis: Every batch is analyzed by HPLC to confirm purity above 99% Batch Consistency: Standardized production reduces variabili…” Source (read 2026-09-25)
36
certificates read
2 / 5
vials outside ±3% of label
1
beyond ±10% (major)
2 / 34
below advertised purity
ProductLabel → measuredPurityMain impurityLabCOA
GW501516-raw-8_6_26_1-scaled.jpeg
10mg → 11.69mg
Overfilled +16.9%
99.79%
Meets 99%
0.21% not itemisedbioviridianOpen
anastrozoleNot measured
89.24%
9.76 pts below 99%
10.76% not itemisedsr-bioOpen
Tirzepatide-30mg-8_1_26-scaled.jpg
30mg → 31.31mg
Over label +4.4%
99.86%
Meets 99%
0.14% not itemisedbioviridianOpen
ClenbuterolNot measured
98.48%
0.52 pts below 99%
1.52% not itemised—Open
Tirzepatide-50mg-8_1_26-scaled.jpg
50mg → 49.61mg
On label -0.8%
99.86%
Meets 99%
0.14% not itemisedbioviridianOpen
T3-3_21_2026-1.jpgNot measured
99.18%
Meets 99%
0.82% not itemisedsr-bioOpen
Dihexa-10mg-7_9_26_1-scaled.jpeg
10mg → 10.26mg
On label +2.6%
99.7%
Meets 99%
0.30% not itemisedbioviridianOpen
5 Amino 1MQNot measured
99.28%
Meets 99%
0.72% not itemisedsr-bioOpen
Aod-9604Not measured
99.48%
Meets 99%
0.52% not itemisedsr-bioOpen
BPC-157/ TB-500Blend, per-component content not listed
99.78%
Meets 99%
0.22% not itemisedsr-bioOpen
Bam15Not measured
99.23%
Meets 99%
0.77% not itemisedsr-bioOpen
EnobosarmNot measured
99.48%
Meets 99%
0.52% not itemisedsr-bioOpen
ExemestaneNot measured
99.71%
Meets 99%
0.29% not itemisedsr-bioOpen
GHK-CU, BPC-157, TB-500, Msh (11-13)Blend, per-component content not listed
99.96%
Meets 99%
0.04% not itemisedsr-bioOpen
GW-0742Not measured
99.19%
Meets 99%
0.81% not itemisedsr-bioOpen
Ghrp-6Not measured
99.41%
Meets 99%
0.59% not itemisedsr-bioOpen
GlutathioneNot measured
99.89%
Meets 99%
0.11% not itemisedsr-bioOpen
KetoprofenNot measured
99.51%
Meets 99%
0.49% not itemisedsr-bioOpen
LL-37Not measured
99.57%
Meets 99%
0.43% not itemisedsr-bioOpen
LetrozoleNot measured
99.33%
Meets 99%
0.67% not itemisedsr-bioOpen
MazdutideNot measured
99.7%
Meets 99%
0.30% not itemisedsr-bioOpen
MechanoNot measured
99.22%
Meets 99%
0.78% not itemisedsr-bioOpen
PralmorelinNot measured
99.69%
Meets 99%
0.31% not itemisedsr-bioOpen
PramipexoleNot measured
99.23%
Meets 99%
0.77% not itemisedsr-bioOpen
RECEIVE CoaisstieD
25mg → 25.36mg
On label +1.4%
——bioviridianOpen
SildenafilNot measured
99.12%
Meets 99%
0.88% not itemisedsr-bioOpen
Snap-8Not measured
99.86%
Meets 99%
0.14% not itemisedsr-bioOpen
Somatotropin (176-191)Not measured
99.82%
Meets 99%
0.18% not itemisedsr-bioOpen
TadalafilNot measured
99.51%
Meets 99%
0.49% not itemisedsr-bioOpen
TamoxifenNot measured
99.19%
Meets 99%
0.81% not itemisedsr-bioOpen
ThyroxineNot measured
99.62%
Meets 99%
0.38% not itemisedsr-bioOpen
TriptorelinNot measured
99.39%
Meets 99%
0.61% not itemisedsr-bioOpen
lbutamorenNot measured
99.91%
Meets 99%
0.09% not itemisedsr-bioOpen
research se,
10mg → 1168mg
Not checked
——bioviridianOpen
research tse,Not measured
99.68%
Meets 99%
0.32% not itemisedbioviridianOpen
tbutamorenNot measured
99.91%
Meets 99%
0.09% not itemisedsr-bioOpen

How this is checked

  • Vial content. Measured net peptide content against the size on the label. Within ±3% is on label, 3–10% is off label, beyond ±10% is a major deviation (under- or overfilled). When a certificate weighs several vials of the batch, the vial farthest from the label is the one judged, and with several purity results the lowest counts. Blends are only checked when the certificate lists each component.
  • Purity. HPLC purity on each certificate against the purity the supplier promises site-wide on its own website. Up to 1 point below the claim is amber, more than that is red. Only a direct promise counts (“99%+ purity guaranteed”); explanations of what purity means, one product's figure and page code are not treated as a claim. A certificate that reports only a bound (“>99%”) is judged only when the bound meets the claim, and a specification line is never read as a result.
  • Whose certificate. A certificate is only read once our client-identity review has looked at it, and one issued to a different company is left out — whether the automatic check or a manual review found it. A certificate issued to the company that runs the supplier's own website counts as the supplier's. A file hosted on another supplier's website is not counted for this one. The same rules decide which certificates appear on supplier and product pages. Only peptide certificates are read: bacteriostatic water, acetic acid and other diluents are left out, and so are product data sheets, which state a specification rather than a batch result.
  • Main impurity. Shown when the certificate itemises it: a named impurity (TFA, deletion sequence, oxidation…) or the largest secondary peak in the HPLC peak table. Most certificates report only a purity figure, so the rest of the sample is not itemised.
  • Trust Score. These checks are 10 of the 25 Transparency points: vial content 7 (full credit within ±3%, half up to ±10%, none beyond, over- and underfilled alike), purity 3 (98% is the bar when a supplier advertises no figure). Fewer than 5 readable results gives half credit rather than a guess.
  • These are the supplier's own published certificates, read automatically from the PDF or image. Janoshik results tables are read twice from the image, cell by cell, and a figure the two readings disagree on is left out rather than guessed. A certificate covers one batch on one date. We have not tested these batches ourselves.

Loti Labs supplier page

Peptide Scanner is an independent aggregator. All content is for research purposes only. We do not sell, ship, or endorse any product. Read full disclaimer →