PeptideScanner
Peptide Scanner does not sell peptides. Independent, not affiliated with any supplier. Disclaimer

Kylo Peptides: claims vs COA

The purity Kylo Peptides advertises and the vial sizes on its labels, checked against the 27 certificates of analysis it publishes.

Website claim: 99% purity. …arch Peptides For Sale: Buy Kylo Peptides Online Guaranteed ≥99% Purity 30-Day Money Back Guarantee Triple Tested Compounds Shop hi… Source (read 2026-09-25)

certificates read
27
vials outside ±3% of label
4 / 6
beyond ±10% (major)
3
below advertised purity
1 / 27

On label, within ±3%Off label, 3 to 10%Major, beyond ±10%How this is checked

Kylo Peptides certificates: label against measured content and purity
ProductLabel to measuredPurityMain impurityLabCOA
BPC-157
10mg → 8.63mg
Underfilled -13.7%
>99.8%
Meets 99%
under 0.20% not itemisedvanguardOpen certificate BPC-157
BPC-157 10mg
10mg → 8.82mg
Underfilled -11.8%
99.8%
Meets 99%
0.20% not itemisedfreedom-diagnosticsOpen certificate BPC-157 10mg
Retatrutide 10mg
10mg → 11.28mg
Overfilled +12.8%
99.87%
Meets 99%
0.13% not itemisedfreedom-diagnosticsOpen certificate Retatrutide 10mg
CJC-1295 no DAC/IpamorelinBlend, per-component content not listed
98.56%
0.44 pts below 99%
1.44% not itemisedvanguardOpen certificate CJC-1295 no DAC/Ipamorelin
GHK-Cu
50mg → 54.63mg
Over label +9.3%
>99.8%
Meets 99%
under 0.20% not itemisedvanguardOpen certificate GHK-Cu
BPC-157
— → 9.21mg
Not checked
99.751%
Meets 99%
0.25% not itemisedjanoshikOpen certificate BPC-157
BPC-157 + TB-500 10+10mgBlend, per-component content not listed
99.6%
Meets 99%
0.40% not itemisedUnknownOpen certificate BPC-157 + TB-500 10+10mg
BPC-157 + TB-500 5+5mgBlend, per-component content not listed
99.5%
Meets 99%
0.50% not itemisedUnknownOpen certificate BPC-157 + TB-500 5+5mg
BPC-157 10mgNot measured
99.81%
Meets 99%
0.19% not itemisedUnknownOpen certificate BPC-157 10mg
CJC-1295/IpamorelinBlend, per-component content not listed
99.62%
Meets 99%
0.38% not itemisedfreedom-diagnosticsOpen certificate CJC-1295/Ipamorelin
GHK-CU 50mgNot measured
99.4%
Meets 99%
0.60% not itemisedUnknownOpen certificate GHK-CU 50mg
GHK-Cu
— → 43.89mg
Not checked
99.23%
Meets 99%
0.77% not itemisedjanoshikOpen certificate GHK-Cu
GHK-Cu 50mg
50mg → 49.39mg
On label -1.2%
99.94%
Meets 99%
0.06% not itemisedfreedom-diagnosticsOpen certificate GHK-Cu 50mg
GLOWBlend, per-component content not listed
>99.5%
Meets 99%
under 0.50% not itemisedvanguardOpen certificate GLOW
GLP-3
10mg → 10.06mg
On label +0.6%
>99.8%
Meets 99%
under 0.20% not itemisedvanguardOpen certificate GLP-3
Glow 70mgBlend, per-component content not listed
99.67%
Meets 99%
0.33% not itemisedfreedom-diagnosticsOpen certificate Glow 70mg
Ipamorelin 5mgNot measured
99%
Meets 99%
1.00% not itemisedUnknownOpen certificate Ipamorelin 5mg
KLOW 80mgBlend, per-component content not listed
99.1%
Meets 99%
0.90% not itemisedUnknownOpen certificate KLOW 80mg
KPV 10mgNot measured
99%
Meets 99%
1.00% not itemisedUnknownOpen certificate KPV 10mg
KPV 5mgNot measured
99.7%
Meets 99%
0.30% not itemisedUnknownOpen certificate KPV 5mg
Klow 80mgBlend, per-component content not listed
99.84%
Meets 99%
0.16% not itemisedfreedom-diagnosticsOpen certificate Klow 80mg
MT-2 (Melanotan) 10mgNot measured
99%
Meets 99%
1.00% not itemisedUnknownOpen certificate MT-2 (Melanotan) 10mg
NAD+ 1000mgNot measured
99.4%
Meets 99%
0.60% not itemisedUnknownOpen certificate NAD+ 1000mg
SS-31 10mgNot measured
99.3%
Meets 99%
0.70% not itemisedUnknownOpen certificate SS-31 10mg
Selank 10mgNot measured
99.3%
Meets 99%
0.70% not itemisedUnknownOpen certificate Selank 10mg
TB-500 10mgNot measured
99.2%
Meets 99%
0.80% not itemisedUnknownOpen certificate TB-500 10mg
Tesamorelin 10mgNot measured
99.2%
Meets 99%
0.80% not itemisedUnknownOpen certificate Tesamorelin 10mg

How this is checked

Vial content
Measured net peptide content against the size on the label. Within ±3% is on label, 3 to 10% is off label, beyond ±10% is a major deviation (under- or overfilled). When a certificate weighs several vials of the batch, the vial farthest from the label is the one judged, and with several purity results the lowest counts. Blends are only checked when the certificate lists each component.
Purity
HPLC purity on each certificate against the purity the supplier promises site-wide on its own website. Up to 1 point below the claim is amber, more than that is red. Only a direct promise counts (“99%+ purity guaranteed”); explanations of what purity means, one product's figure and page code are not treated as a claim. A certificate that reports only a bound (“>99%”) is judged only when the bound meets the claim, and a specification line is never read as a result.
Whose certificate
A certificate is only read once our client-identity review has looked at it, and one issued to a different company is left out, whether the automatic check or a manual review found it. A certificate issued to the company that runs the supplier's own website counts as the supplier's. A file hosted on another supplier's website is not counted for this one. The same rules decide which certificates appear on supplier and product pages. Only peptide certificates are read: bacteriostatic water, acetic acid and other diluents are left out, and so are product data sheets, which state a specification rather than a batch result.
Main impurity
Shown when the certificate itemises it: a named impurity (TFA, deletion sequence, oxidation…) or the largest secondary peak in the HPLC peak table. Most certificates report only a purity figure, so the rest of the sample is not itemised.
Trust Score
These checks are 10 of the 25 Transparency points: vial content 7 (full credit within ±3%, half up to ±10%, none beyond, over- and underfilled alike), purity 3 (98% is the bar when a supplier advertises no figure). Fewer than 5 readable results gives half credit rather than a guess.
Source and limits
These are the supplier's own published certificates, read automatically from the PDF or image. Janoshik results tables are read twice from the image, cell by cell, and a figure the two readings disagree on is left out rather than guessed. A certificate covers one batch on one date. We have not tested these batches ourselves.

Kylo Peptides supplier page and all suppliers on Claims vs COA