PeptideScanner
Peptide Scanner does not sell peptides. Independent, not affiliated with any supplier. Disclaimer

KÖLD: claims vs COA

The purity KÖLD advertises and the vial sizes on its labels, checked against the 14 certificates of analysis it publishes.

No site-wide purity promise found on the website. Vial content is still checked against the label.

certificates read
14
vials outside ±3% of label
6 / 7
beyond ±10% (major)
5
below advertised purity
None

On label, within ±3%Off label, 3 to 10%Major, beyond ±10%How this is checked

KÖLD certificates: label against measured content and purity
ProductLabel to measuredPurityMain impurityLabCOA
AOD-9604 i
5mg → 5.91mg
Overfilled +18.2%
99.727%
0.27% not itemisedUnknownOpen certificate AOD-9604 i
GHK-Cu a
50mg → 56.93mg
Overfilled +13.9%
>98%
under 2.00% not itemisedUnknownOpen certificate GHK-Cu a
Melanotan II
10mg → 8.9mg
Underfilled -11.0%
99.075%
0.92% not itemisedUnknownOpen certificate Melanotan II
Semax
30mg → 33.45mg
Overfilled +11.5%
99.57%
0.43% not itemisedUnknownOpen certificate Semax
lpamorelin i
5mg → 5.97mg
Overfilled +19.4%
99.453%
0.55% not itemisedUnknownOpen certificate lpamorelin i
Retatrutide a
10mg → 10.37mg
Over label +3.7%
99.9%
0.10% not itemisedUnknownOpen certificate Retatrutide a
KLD-CND5-COA-scaled.png
— → 4.26mg
Not checked
99.75%
0.25% not itemisedUnknownOpen certificate KLD-CND5-COA-scaled.png
BLENDBlend, per-component content not listed
>98%
under 2.00% not itemisedUnknownOpen certificate BLEND
BPC-157, TB-500 iiBlend, per-component content not listed
98.62%
1.38% not itemisedUnknownOpen certificate BPC-157, TB-500 ii
C-Amylin, G1-S iiBlend, per-component content not listed
99.38%
0.62% not itemisedUnknownOpen certificate C-Amylin, G1-S ii
CJC-1295 (no DAC), Ilpamorelin iiBlend, per-component content not listed
99.08%
0.92% not itemisedUnknownOpen certificate CJC-1295 (no DAC), Ilpamorelin ii
NAD+ i
500mg → 508.97mg
On label +1.8%
99.68%
0.32% not itemisedUnknownOpen certificate NAD+ i
Oxytocin aNot measured
99.063%
0.94% not itemisedUnknownOpen certificate Oxytocin a
Retatrutide 2B
— → 28.5mg
Not checked
99.984%
0.02% not itemisedUnknownOpen certificate Retatrutide 2B

How this is checked

Vial content
Measured net peptide content against the size on the label. Within ±3% is on label, 3 to 10% is off label, beyond ±10% is a major deviation (under- or overfilled). When a certificate weighs several vials of the batch, the vial farthest from the label is the one judged, and with several purity results the lowest counts. Blends are only checked when the certificate lists each component.
Purity
HPLC purity on each certificate against the purity the supplier promises site-wide on its own website. Up to 1 point below the claim is amber, more than that is red. Only a direct promise counts (“99%+ purity guaranteed”); explanations of what purity means, one product's figure and page code are not treated as a claim. A certificate that reports only a bound (“>99%”) is judged only when the bound meets the claim, and a specification line is never read as a result.
Whose certificate
A certificate is only read once our client-identity review has looked at it, and one issued to a different company is left out, whether the automatic check or a manual review found it. A certificate issued to the company that runs the supplier's own website counts as the supplier's. A file hosted on another supplier's website is not counted for this one. The same rules decide which certificates appear on supplier and product pages. Only peptide certificates are read: bacteriostatic water, acetic acid and other diluents are left out, and so are product data sheets, which state a specification rather than a batch result.
Main impurity
Shown when the certificate itemises it: a named impurity (TFA, deletion sequence, oxidation…) or the largest secondary peak in the HPLC peak table. Most certificates report only a purity figure, so the rest of the sample is not itemised.
Trust Score
These checks are 10 of the 25 Transparency points: vial content 7 (full credit within ±3%, half up to ±10%, none beyond, over- and underfilled alike), purity 3 (98% is the bar when a supplier advertises no figure). Fewer than 5 readable results gives half credit rather than a guess.
Source and limits
These are the supplier's own published certificates, read automatically from the PDF or image. Janoshik results tables are read twice from the image, cell by cell, and a figure the two readings disagree on is left out rather than guessed. A certificate covers one batch on one date. We have not tested these batches ourselves.

KÖLD supplier page and all suppliers on Claims vs COA