PeptideScanner
Peptide Scanner does not sell peptides. Independent, not affiliated with any supplier. Disclaimer

Injectify: claims vs COA

The purity Injectify advertises and the vial sizes on its labels, checked against the 19 certificates of analysis it publishes.

Website claim: 99.5% purity. …ity before it ships. Shop best sellers → View lab results ≥ 99.5% Verified purity ISO Certified labs 3-stage Batch testing Third-party lab te… Source (read 2026-09-25)

certificates read
19
vials outside ±3% of label
15 / 18
beyond ±10% (major)
5
below advertised purity
8 / 19

On label, within ±3%Off label, 3 to 10%Major, beyond ±10%How this is checked

Injectify certificates: label against measured content and purity
ProductLabel to measuredPurityMain impurityLabCOA
DSIP 5 mg
5mg → 5.22mg
Over label +4.4%
97.146%
2.35 pts below 99.5%
2.85% not itemisedjanoshikOpen certificate DSIP 5 mg
IGF-1 LR3 1 mg
1mg → 0.95mg
Under label -5.0%
94.676%
4.82 pts below 99.5%
5.32% not itemisedjanoshikOpen certificate IGF-1 LR3 1 mg
10 mg
10mg → 12.35mg
Overfilled +23.5%
99.693%
Meets 99.5%
0.31% not itemisedjanoshikOpen certificate 10 mg
BPC-157 5mg
5mg → 5.76mg
Overfilled +15.2%
99.821%
Meets 99.5%
0.18% not itemisedjanoshikOpen certificate BPC-157 5mg
CJC without DAC 5 mg
5mg → 5.23mg
Over label +4.6%
99.094%
0.41 pts below 99.5%
0.91% not itemisedjanoshikOpen certificate CJC without DAC 5 mg
GHK-Cu 50 mg
50mg → 47.3mg
Under label -5.4%
99.262%
0.24 pts below 99.5%
0.74% not itemisedjanoshikOpen certificate GHK-Cu 50 mg
IGF-1 LR3 1 mg
1mg → 0.84mg
Underfilled -16.0%
99.522%
Meets 99.5%
0.48% not itemisedjanoshikOpen certificate IGF-1 LR3 1 mg
Kisspeptin-10 10 mg
10mg → 11.09mg
Overfilled +10.9%
99.665%
Meets 99.5%
0.33% not itemisedjanoshikOpen certificate Kisspeptin-10 10 mg
Selank 5 mg
5mg → 5.94mg
Overfilled +18.8%
99.761%
Meets 99.5%
0.24% not itemisedjanoshikOpen certificate Selank 5 mg
Semax 5 mg
5mg → 5.17mg
Over label +3.4%
99.344%
0.16 pts below 99.5%
0.66% not itemisedjanoshikOpen certificate Semax 5 mg
BPC-157 10mg
10mg → 9.43mg
Under label -5.7%
99.86%
Meets 99.5%
0.14% not itemisedjanoshikOpen certificate BPC-157 10mg
CJC with DAC 5 mg
5mg → 5.06mg
On label +1.2%
98.67%
0.83 pts below 99.5%
1.33% not itemisedjanoshikOpen certificate CJC with DAC 5 mg
GHK-Cu 100 mg
100mg → 100.15mg
On label +0.2%
99.326%
0.17 pts below 99.5%
0.67% not itemisedjanoshikOpen certificate GHK-Cu 100 mg
KPV 5 mg
5mg → 5.22mg
Over label +4.4%
99.91%
Meets 99.5%
0.09% not itemisedjanoshikOpen certificate KPV 5 mg
Mots-C 10 mg
10mg → 10.92mg
Over label +9.2%
99.804%
Meets 99.5%
0.20% not itemisedjanoshikOpen certificate Mots-C 10 mg
Retatrutide (GLP-3) 10 mg
10mg → 9.96mg
On label -0.4%
99.229%
0.27 pts below 99.5%
0.77% not itemisedjanoshikOpen certificate Retatrutide (GLP-3) 10 mg
Retatrutide (GLP-3) 20 mg
20mg → 21.45mg
Over label +7.3%
99.783%
Meets 99.5%
0.22% not itemisedjanoshikOpen certificate Retatrutide (GLP-3) 20 mg
TB500 10mg
10mg → 10.91mg
Over label +9.1%
99.823%
Meets 99.5%
0.18% not itemisedjanoshikOpen certificate TB500 10mg
Melanotan-2
— → 10.54mg
Not checked
99.87%
Meets 99.5%
0.13% not itemisedjanoshikOpen certificate Melanotan-2

How this is checked

Vial content
Measured net peptide content against the size on the label. Within ±3% is on label, 3 to 10% is off label, beyond ±10% is a major deviation (under- or overfilled). When a certificate weighs several vials of the batch, the vial farthest from the label is the one judged, and with several purity results the lowest counts. Blends are only checked when the certificate lists each component.
Purity
HPLC purity on each certificate against the purity the supplier promises site-wide on its own website. Up to 1 point below the claim is amber, more than that is red. Only a direct promise counts (“99%+ purity guaranteed”); explanations of what purity means, one product's figure and page code are not treated as a claim. A certificate that reports only a bound (“>99%”) is judged only when the bound meets the claim, and a specification line is never read as a result.
Whose certificate
A certificate is only read once our client-identity review has looked at it, and one issued to a different company is left out, whether the automatic check or a manual review found it. A certificate issued to the company that runs the supplier's own website counts as the supplier's. A file hosted on another supplier's website is not counted for this one. The same rules decide which certificates appear on supplier and product pages. Only peptide certificates are read: bacteriostatic water, acetic acid and other diluents are left out, and so are product data sheets, which state a specification rather than a batch result.
Main impurity
Shown when the certificate itemises it: a named impurity (TFA, deletion sequence, oxidation…) or the largest secondary peak in the HPLC peak table. Most certificates report only a purity figure, so the rest of the sample is not itemised.
Trust Score
These checks are 10 of the 25 Transparency points: vial content 7 (full credit within ±3%, half up to ±10%, none beyond, over- and underfilled alike), purity 3 (98% is the bar when a supplier advertises no figure). Fewer than 5 readable results gives half credit rather than a guess.
Source and limits
These are the supplier's own published certificates, read automatically from the PDF or image. Janoshik results tables are read twice from the image, cell by cell, and a figure the two readings disagree on is left out rather than guessed. A certificate covers one batch on one date. We have not tested these batches ourselves.

Injectify supplier page and all suppliers on Claims vs COA