PeptideScanner

Claims vs COA / HYTE Research Division

HYTE Research Division: claims vs COA

No site-wide purity promise found on the website. Vial content is still checked against the label.
32
certificates read
8 / 9
vials outside ±3% of label
1
beyond ±10% (major)
—
below advertised purity
ProductLabel → measuredPurityMain impurityLabCOA
Tesamorelin 10mg
10mg → 11.56mg
Overfilled +15.6%
99.179%
0.82% not itemisedfreedom-diagnosticsOpen
GLP-3-RT 10MG
10mg → 10.51mg
Over label +5.1%
99.982%
0.02% not itemisedfreedom-diagnosticsOpen
GLP-3-RT 10mg
10mg → 9.21mg
Under label -7.9%
99.884%
0.12% not itemisedfreedom-diagnosticsOpen
GLP-3-RT 20MG
20mg → 20.97mg
Over label +4.9%
99.914%
0.09% not itemisedfreedom-diagnosticsOpen
GLP-3-RT 20mg
20mg → 19.02mg
Under label -4.9%
99.933%
0.07% not itemisedfreedom-diagnosticsOpen
Retatrutide 20mg
20mg → 21.57mg
Over label +7.9%
99.59%
0.41% not itemisedfreedom-diagnosticsOpen
Semaglutide 20mg
20mg → 21.55mg
Over label +7.8%
99.7%
0.30% not itemisedfreedom-diagnosticsOpen
Tirzepatide 20mg
20mg → 20.64mg
Over label +3.2%
99.87%
0.13% not itemisedfreedom-diagnosticsOpen
Hyte2601150010.pdfNot measured
99.887%
0.11% not itemisedfreedom-diagnosticsOpen
BAM-15Not measured
>99%
under 1.00% not itemised—Open
BPC-157Not measured
>99%
under 1.00% not itemised—Open
BPC-157Not measured
>99%
under 1.00% not itemised—Open
BromantaneNot measured
>99%
under 1.00% not itemised—Open
CJC-1295 no DAC + IpamorelinBlend, per-component content not listed
99.37%
0.63% not itemisedfreedom-diagnosticsOpen
DMAA HClNot measured
>99%
under 1.00% not itemised—Open
DMAA HClNot measured
>99%
under 1.00% not itemised—Open
Enclomiphene CitrateNot measured
>99%
under 1.00% not itemised—Open
Enclomophine 12.5mg Citrate Capsules
12.5mg → 12.33mg
On label -1.4%
99.76%
0.24% not itemisedfreedom-diagnosticsOpen
GLOW 70mgBlend, per-component content not listed
99.837%
0.16% not itemisedfreedom-diagnosticsOpen
HCGNot measured
>99%
under 1.00% not itemised—Open
LGD-4033Not measured
>99%
under 1.00% not itemised—Open
MK-2866 (Ostarine)Not measured
>99%
under 1.00% not itemised—Open
MK-677Not measured
>99%
under 1.00% not itemised—Open
MT-IINot measured
>99%
under 1.00% not itemised—Open
NAD+Not measured
>98%
under 2.00% not itemised—Open
RAD-140Not measured
>99%
under 1.00% not itemised—Open
RetatrutideNot measured
>99%
under 1.00% not itemised—Open
SLU-PP-332Not measured
>99%
under 1.00% not itemised—Open
TB-500Not measured
>99%
under 1.00% not itemised—Open
Tadalafil CitrateNot measured
>99%
under 1.00% not itemised—Open
TelmisartanNot measured
>99%
under 1.00% not itemised—Open
Tesamorelin AcetateNot measured
>99%
under 1.00% not itemised—Open

How this is checked

  • Vial content. Measured net peptide content against the size on the label. Within ±3% is on label, 3–10% is off label, beyond ±10% is a major deviation (under- or overfilled). When a certificate weighs several vials of the batch, the vial farthest from the label is the one judged, and with several purity results the lowest counts. Blends are only checked when the certificate lists each component.
  • Purity. HPLC purity on each certificate against the purity the supplier promises site-wide on its own website. Up to 1 point below the claim is amber, more than that is red. Only a direct promise counts (“99%+ purity guaranteed”); explanations of what purity means, one product's figure and page code are not treated as a claim. A certificate that reports only a bound (“>99%”) is judged only when the bound meets the claim, and a specification line is never read as a result.
  • Whose certificate. A certificate is only read once our client-identity review has looked at it, and one issued to a different company is left out — whether the automatic check or a manual review found it. A certificate issued to the company that runs the supplier's own website counts as the supplier's. A file hosted on another supplier's website is not counted for this one. The same rules decide which certificates appear on supplier and product pages. Only peptide certificates are read: bacteriostatic water, acetic acid and other diluents are left out, and so are product data sheets, which state a specification rather than a batch result.
  • Main impurity. Shown when the certificate itemises it: a named impurity (TFA, deletion sequence, oxidation…) or the largest secondary peak in the HPLC peak table. Most certificates report only a purity figure, so the rest of the sample is not itemised.
  • Trust Score. These checks are 10 of the 25 Transparency points: vial content 7 (full credit within ±3%, half up to ±10%, none beyond, over- and underfilled alike), purity 3 (98% is the bar when a supplier advertises no figure). Fewer than 5 readable results gives half credit rather than a guess.
  • These are the supplier's own published certificates, read automatically from the PDF or image. Janoshik results tables are read twice from the image, cell by cell, and a figure the two readings disagree on is left out rather than guessed. A certificate covers one batch on one date. We have not tested these batches ourselves.

HYTE Research Division supplier page

Peptide Scanner is an independent aggregator. All content is for research purposes only. We do not sell, ship, or endorse any product. Read full disclaimer →