PeptideScanner

Claims vs COA / Hydro Research

Hydro Research: claims vs COA

Website claim: 99% purity. “…ormation, lab-backed resources, and research-use materials. 99%+ purity focus COA testing proof 21+ research access Hydro Research…” Source (read 2026-09-25)
58
certificates read
38 / 43
vials outside ±3% of label
23
beyond ±10% (major)
4 / 52
below advertised purity
ProductLabel → measuredPurityMain impurityLabCOA
5 mg
5mg → 5.97mg
Overfilled +19.4%
98.707%
0.29 pts below 99%
1.29% not itemisedjanoshikOpen
KPV 10 mg
10mg → 12.66mg
Overfilled +26.6%
98.157%
0.84 pts below 99%
1.84% not itemisedjanoshikOpen
TB-500 10 mg
10mg → 11.1mg
Overfilled +11.0%
98.322%
0.68 pts below 99%
1.68% not itemisedjanoshikOpen
Tesamorelin 10mg
10mg → 11.35mg
Overfilled +13.5%
98.507%
0.49 pts below 99%
1.49% not itemisedjanoshikOpen
5-Amino-1 MQ 50 mg
50mg → 44.38mg
Underfilled -11.2%
——janoshikOpen
BPC 5 mg
5mg → 5.57mg
Overfilled +11.4%
99.645%
Meets 99%
0.36% not itemisedjanoshikOpen
CJCNo Dac 5 mg
5mg → 5.9mg
Overfilled +18.0%
99.536%
Meets 99%
0.46% not itemisedjanoshikOpen
Cagrilitide 5 mg
5mg → 6.24mg
Overfilled +24.8%
99.931%
Meets 99%
0.07% not itemisedjanoshikOpen
GHK-CU 100mg
100mg → 110.53mg
Overfilled +10.5%
99.564%
Meets 99%
0.44% not itemisedjanoshikOpen
L-Glutathione 1500mg
1500mg → 1689.04mg
Overfilled +12.6%
99.208%
Meets 99%
0.79% not itemisedjanoshikOpen
Melanotan Il 10mg
10mg → 8.18mg
Underfilled -18.2%
99.455%
Meets 99%
0.55% not itemisedjanoshikOpen
Melanotan | 10mg
10mg → 8.5mg
Underfilled -15.0%
99.597%
Meets 99%
0.40% not itemisedjanoshikOpen
Selank 5 mg
5mg → 7.23mg
Overfilled +44.6%
99.037%
Meets 99%
0.96% not itemisedjanoshikOpen
Tesamorelin 6mg/Ipa 2 mg
Tesamorelin: 6mg → 6.98mg Overfilled +16.3%
Ipamorelin: 2mg → 1.93mg Under label -3.5%
——janoshikOpen
Thymosin 1 10mg
10mg → 12.42mg
Overfilled +24.2%
99.164%
Meets 99%
0.84% not itemisedjanoshikOpen
Tirzepatide 10 mg
10mg → 11.48mg
Overfilled +14.8%
99.656%
Meets 99%
0.34% not itemisedjanoshikOpen
Tirzepatide 100 mg
100mg → 110.64mg
Overfilled +10.6%
99.92%
Meets 99%
0.08% not itemisedjanoshikOpen
Tirzepatide 15 mg
15mg → 17.34mg
Overfilled +15.6%
99.655%
Meets 99%
0.34% not itemisedjanoshikOpen
Tirzepatide 30 mg
30mg → 35.05mg
Overfilled +16.8%
99.858%
Meets 99%
0.14% not itemisedjanoshikOpen
Tirzepatide 5 mg
5mg → 5.66mg
Overfilled +13.2%
99.388%
Meets 99%
0.61% not itemisedjanoshikOpen
Tirzepatide 60 mg
60mg → 68.98mg
Overfilled +15.0%
99.845%
Meets 99%
0.16% not itemisedjanoshikOpen
lpamoralin 5 mg
5mg → 5.72mg
Overfilled +14.4%
99.86%
Meets 99%
0.14% not itemisedjanoshikOpen
vial or vials
BPC-157: 5mg → 6.14mg Overfilled +22.8%
TB-500 (TB4): 5mg → 5.27mg Over label +5.4%
——janoshikOpen
60 mg
60mg → 66mg
Over label +10.0%
99.763%
Meets 99%
0.24% not itemisedjanoshikOpen
Adamax
5mg → 5.19mg
Over label +3.8%
99.44%
Meets 99%
0.56% not itemisedils-labsOpen
BPC-157 10mg
10mg → 10.6mg
Over label +6.0%
99.713%
Meets 99%
0.29% not itemisedjanoshikOpen
Retatrutide
10mg → 10.66mg
Over label +6.6%
99.57%
Meets 99%
0.43% not itemisedils-labsOpen
Retatrutide
40mg → 42.64mg
Over label +6.6%
99.9%
Meets 99%
0.10% not itemisedils-labsOpen
Retatrutide
5mg → 5.17mg
Over label +3.4%
99.71%
Meets 99%
0.29% not itemisedils-labsOpen
Retatrutide
60mg → 63.39mg
Over label +5.7%
99.94%
Meets 99%
0.06% not itemisedils-labsOpen
Semaglutide
10mg → 10.64mg
Over label +6.4%
99.76%
Meets 99%
0.24% not itemisedils-labsOpen
Sermorelin
10mg → 10.35mg
Over label +3.5%
99.87%
Meets 99%
0.13% not itemisedils-labsOpen
Tirzepatide
30mg → 31.67mg
Over label +5.6%
99.98%
Meets 99%
0.02% not itemisedils-labsOpen
Tirzepatide
10mg → 10.48mg
Over label +4.8%
99.78%
Meets 99%
0.22% not itemisedils-labsOpen
Tirzepatide
100mg → 105.11mg
Over label +5.1%
99.8%
Meets 99%
0.20% not itemisedils-labsOpen
Tirzepatide
15mg → 15.64mg
Over label +4.3%
99.88%
Meets 99%
0.12% not itemisedils-labsOpen
Tirzepatide
20mg → 21.25mg
Over label +6.3%
99.91%
Meets 99%
0.09% not itemisedils-labsOpen
Tirzepatide
60mg → 63.29mg
Over label +5.5%
99.86%
Meets 99%
0.14% not itemisedils-labsOpen
ILS-H-C-S.pdfNot measured
99.8%
Meets 99%
0.20% not itemisedils-labsOpen
ILS-H-C-R.pdfNot measured
99.87%
Meets 99%
0.13% not itemisedils-labsOpen
Adamax 5mg
5mg → 5.06mg
On label +1.2%
99.232%
Meets 99%
0.77% not itemisedjanoshikOpen
CagrilintideNot measured
99.72%
Meets 99%
0.28% not itemisedils-labsOpen
DSIPNot measured
99.856%
Meets 99%
0.14% not itemisedjanoshikOpen
EpithalonNot measured
99.576%
Meets 99%
0.42% not itemisedjanoshikOpen
GHK
— → 108.27mg
Not checked
99.859%
Meets 99%
0.14% not itemisedjanoshikOpen
IGF-LR3
— → 1.07mg
Not checked
——janoshikOpen
Kisspeptin
10mg → 10.27mg
On label +2.7%
99.25%
Meets 99%
0.75% not itemisedils-labsOpen
Kisspeptin
— → 11.89mg
Not checked
99.817%
Meets 99%
0.18% not itemisedjanoshikOpen
MOTS-c
— → 11.74mg
Not checked
99.712%
Meets 99%
0.29% not itemisedjanoshikOpen
Methylcobalamin
— → 4.92mg
Not checked
——janoshikOpen
NAD+
— → 1050.28mg
Not checked
——janoshikOpen
Retatrutide
20mg → 20.53mg
On label +2.7%
99.86%
Meets 99%
0.14% not itemisedils-labsOpen
SNAP-8Not measured
99.63%
Meets 99%
unidentified peak at 1.5 min 0.5%mz-biolabsOpen
SS-31 50 mg
50mg → 49.87mg
On label -0.3%
99.793%
Meets 99%
0.21% not itemisedjanoshikOpen
Semaglutide
5mg → 5.13mg
On label +2.6%
99.47%
Meets 99%
0.53% not itemisedils-labsOpen
Semax
— → 11.91mg
Not checked
99.588%
Meets 99%
0.41% not itemisedjanoshikOpen
Sermorelin
— → 10.24mg
Not checked
99.721%
Meets 99%
0.28% not itemisedjanoshikOpen
Snap-8Not measured
99.828%
Meets 99%
0.17% not itemisedjanoshikOpen

How this is checked

  • Vial content. Measured net peptide content against the size on the label. Within ±3% is on label, 3–10% is off label, beyond ±10% is a major deviation (under- or overfilled). When a certificate weighs several vials of the batch, the vial farthest from the label is the one judged, and with several purity results the lowest counts. Blends are only checked when the certificate lists each component.
  • Purity. HPLC purity on each certificate against the purity the supplier promises site-wide on its own website. Up to 1 point below the claim is amber, more than that is red. Only a direct promise counts (“99%+ purity guaranteed”); explanations of what purity means, one product's figure and page code are not treated as a claim. A certificate that reports only a bound (“>99%”) is judged only when the bound meets the claim, and a specification line is never read as a result.
  • Whose certificate. A certificate is only read once our client-identity review has looked at it, and one issued to a different company is left out — whether the automatic check or a manual review found it. A certificate issued to the company that runs the supplier's own website counts as the supplier's. A file hosted on another supplier's website is not counted for this one. The same rules decide which certificates appear on supplier and product pages. Only peptide certificates are read: bacteriostatic water, acetic acid and other diluents are left out, and so are product data sheets, which state a specification rather than a batch result.
  • Main impurity. Shown when the certificate itemises it: a named impurity (TFA, deletion sequence, oxidation…) or the largest secondary peak in the HPLC peak table. Most certificates report only a purity figure, so the rest of the sample is not itemised.
  • Trust Score. These checks are 10 of the 25 Transparency points: vial content 7 (full credit within ±3%, half up to ±10%, none beyond, over- and underfilled alike), purity 3 (98% is the bar when a supplier advertises no figure). Fewer than 5 readable results gives half credit rather than a guess.
  • These are the supplier's own published certificates, read automatically from the PDF or image. Janoshik results tables are read twice from the image, cell by cell, and a figure the two readings disagree on is left out rather than guessed. A certificate covers one batch on one date. We have not tested these batches ourselves.

Hydro Research supplier page

Peptide Scanner is an independent aggregator. All content is for research purposes only. We do not sell, ship, or endorse any product. Read full disclaimer →