No site-wide purity promise found on the website. Vial content is still checked against the label.
31
certificates read
18 / 26
vials outside ±3% of label
8
beyond ±10% (major)
—
below advertised purity
ProductLabel → measuredPurityMain impurityLabCOA
Cartalax 20mg
20mg → 23.18mg
Overfilled +15.9%
99.58%
0.42% not itemisedfreedom-diagnosticsOpen
DSIP 10mg
10mg → 11.31mg
Overfilled +13.1%
99.27%
0.73% not itemisedfreedom-diagnosticsOpen
Epithalon
10mg → 12.03mg
Overfilled +20.3%
99.11%
0.89% not itemisedtestidesOpen
GLP SM 20mg
20mg → 25.91mg
Overfilled +29.6%
99.94%
0.06% not itemisedfreedom-diagnosticsOpen
IGF1 LR3
1mg → 1.29mg
Overfilled +29.0%
97.04%
2.96% not itemisedtestidesOpen
Retatrutide 10mg
10mg → 11.3mg
Overfilled +13.0%
99.79%
0.21% not itemisedfreedom-diagnosticsOpen
Retatrutide 20mg
20mg → 23.57mg
Overfilled +17.9%
99.85%
0.15% not itemisedfreedom-diagnosticsOpen
Tesamorelin 10mg
10mg → 11.15mg
Overfilled +11.5%
99.58%
0.42% not itemisedfreedom-diagnosticsOpen
5-Amino-1MQ 50mg
50mg → 45.61mg
Under label -8.8%
——freedom-diagnosticsOpen
BPC-157
10mg → 9.63mg
Under label -3.7%
98.6%
1.40% not itemisedtestidesOpen
Ipamorelin 10mg
10mg → 10.56mg
Over label +5.6%
99.87%
0.13% not itemisedfreedom-diagnosticsOpen
KPV 10mg
10mg → 10.32mg
Over label +3.2%
99.9%
0.10% not itemisedfreedom-diagnosticsOpen
MOTS-c 20mg
20mg → 18.24mg
Under label -8.8%
99.9%
0.10% not itemisedfreedom-diagnosticsOpen
Melanotan II
10mg → 10.93mg
Over label +9.3%
98.77%
1.23% not itemisedtestidesOpen
Retatrutide
5mg → 5.26mg
Over label +5.2%
99.36%
0.64% not itemisedtestidesOpen
Retatrutide
10mg → 10.91mg
Over label +9.1%
99.53%
0.47% not itemisedtestidesOpen
Selank 10mg
10mg → 10.69mg
Over label +6.9%
99.64%
0.36% not itemisedfreedom-diagnosticsOpen
TB-500
10mg → 10.7mg
Over label +7.0%
99.76%
0.24% not itemisedtestidesOpen
BPC/TB BlendBlend, per-component content not listed
99.03%
0.97% not itemisedtestidesOpen
CJC-1295 (mod GRF 1-29)
10mg → 10.08mg
On label +0.8%
99.24%
0.76% not itemisedtestidesOpen
CJC-1295/Ipamorelin 5mg/5mgBlend, per-component content not listed
99.91%
0.09% not itemisedfreedom-diagnosticsOpen
GHK-Cu/BPC-157/TB-500 50mg/10mg/10mgBlend, per-component content not listed
99.71%
0.29% not itemisedfreedom-diagnosticsOpen
HGHNot measured
94.84%
5.16% not itemisedtestidesOpen
KLOW BlendBlend, per-component content not listed
99.17%
0.83% not itemisedtestidesOpen
MOTS-c
10mg → 10.09mg
On label +0.9%
99.8%
0.20% not itemisedtestidesOpen
MOTS-c 40mg
40mg → 39.44mg
On label -1.4%
99.6%
0.40% not itemisedfreedom-diagnosticsOpen
NAD+
1000mg → 1026.49mg
On label +2.6%
99.69%
0.31% not itemisedtestidesOpen
PT-141 10mg
10mg → 10.24mg
On label +2.4%
99.5%
0.50% not itemisedfreedom-diagnosticsOpen
Retatrutide
20mg → 20.42mg
On label +2.1%
99.67%
0.33% not itemisedtestidesOpen
SEMAX
10mg → 10.22mg
On label +2.2%
99.26%
0.74% not itemisedtestidesOpen
SS-31 50mg
50mg → 51.39mg
On label +2.8%
99.87%
0.13% not itemisedfreedom-diagnosticsOpen

How this is checked

  • Vial content. Measured net peptide content against the size on the label. Within ±3% is on label, 3–10% is off label, beyond ±10% is a major deviation (under- or overfilled). When a certificate weighs several vials of the batch, the vial farthest from the label is the one judged, and with several purity results the lowest counts. Blends are only checked when the certificate lists each component.
  • Purity. HPLC purity on each certificate against the purity the supplier promises site-wide on its own website. Up to 1 point below the claim is amber, more than that is red. Only a direct promise counts (“99%+ purity guaranteed”); explanations of what purity means, one product's figure and page code are not treated as a claim. A certificate that reports only a bound (“>99%”) is judged only when the bound meets the claim, and a specification line is never read as a result.
  • Whose certificate. A certificate is only read once our client-identity review has looked at it, and one issued to a different company is left out — whether the automatic check or a manual review found it. A certificate issued to the company that runs the supplier's own website counts as the supplier's. A file hosted on another supplier's website is not counted for this one. The same rules decide which certificates appear on supplier and product pages. Only peptide certificates are read: bacteriostatic water, acetic acid and other diluents are left out, and so are product data sheets, which state a specification rather than a batch result.
  • Main impurity. Shown when the certificate itemises it: a named impurity (TFA, deletion sequence, oxidation…) or the largest secondary peak in the HPLC peak table. Most certificates report only a purity figure, so the rest of the sample is not itemised.
  • Trust Score. These checks are 10 of the 25 Transparency points: vial content 7 (full credit within ±3%, half up to ±10%, none beyond, over- and underfilled alike), purity 3 (98% is the bar when a supplier advertises no figure). Fewer than 5 readable results gives half credit rather than a guess.
  • These are the supplier's own published certificates, read automatically from the PDF or image. Janoshik results tables are read twice from the image, cell by cell, and a figure the two readings disagree on is left out rather than guessed. A certificate covers one batch on one date. We have not tested these batches ourselves.

Everlong Research Ltd. supplier page

Peptide Scanner is an independent aggregator. All content is for research purposes only. We do not sell, ship, or endorse any product. Read full disclaimer →