PeptideScanner
Peptide Scanner does not sell peptides. Independent, not affiliated with any supplier. Disclaimer

Eros Peptides: claims vs COA

The purity Eros Peptides advertises and the vial sizes on its labels, checked against the 13 certificates of analysis it publishes.

No site-wide purity promise found on the website. Vial content is still checked against the label.

certificates read
13
vials outside ±3% of label
8 / 9
beyond ±10% (major)
4
below advertised purity
None

On label, within ±3%Off label, 3 to 10%Major, beyond ±10%How this is checked

Eros Peptides certificates: label against measured content and purity
ProductLabel to measuredPurityMain impurityLabCOA
GHK-Cu 100mg
100mg → 117.6mg
Overfilled +17.6%
99.83%
0.17% not itemisedfreedom-diagnosticsOpen certificate GHK-Cu 100mg
Pinealon 20mg
20mg → 26.14mg
Overfilled +30.7%
99.67%
0.33% not itemisedfreedom-diagnosticsOpen certificate Pinealon 20mg
T 20mg
20mg → 24.62mg
Overfilled +23.1%
99.95%
0.05% not itemisedfreedom-diagnosticsOpen certificate T 20mg
TB-500 10mg
10mg → 12.12mg
Overfilled +21.2%
99.83%
0.17% not itemisedfreedom-diagnosticsOpen certificate TB-500 10mg
Thymosin Alpha-1 10mg
10mg → 10.33mg
Over label +3.3%
99.76%
0.24% not itemisedfreedom-diagnosticsOpen certificate Thymosin Alpha-1 10mg
Tirzepatide 30 MG Sample A
30mg → 32.84mg
Over label +9.5%
99.776%
0.22% not itemisedjanoshikOpen certificate Tirzepatide 30 MG Sample A
Tirzepatide 30 MG Sample B
30mg → 32.56mg
Over label +8.5%
99.853%
0.15% not itemisedjanoshikOpen certificate Tirzepatide 30 MG Sample B
Tirzepatide 30 MG Sample C
30mg → 32.05mg
Over label +6.8%
99.831%
0.17% not itemisedjanoshikOpen certificate Tirzepatide 30 MG Sample C
7125 125mg
125mg → 126.34mg
On label +1.1%
99.93%
0.07% not itemisedfreedom-diagnosticsOpen certificate 7125 125mg
AOD-9604 Smg
— → 6.11mg
Not checked
99.75%
0.25% not itemisedfreedom-diagnosticsOpen certificate AOD-9604 Smg
BPC-157/TB-500Blend, per-component content not listed
>99.5%
under 0.50% not itemisedvanguardOpen certificate BPC-157/TB-500
CJC-1295 w/o DAC 5mgBlend, per-component content not listed
99.12%
0.88% not itemisedfreedom-diagnosticsOpen certificate CJC-1295 w/o DAC 5mg
NAD+Not measured
96.6%
3.40% not itemisedvanguardOpen certificate NAD+

How this is checked

Vial content
Measured net peptide content against the size on the label. Within ±3% is on label, 3 to 10% is off label, beyond ±10% is a major deviation (under- or overfilled). When a certificate weighs several vials of the batch, the vial farthest from the label is the one judged, and with several purity results the lowest counts. Blends are only checked when the certificate lists each component.
Purity
HPLC purity on each certificate against the purity the supplier promises site-wide on its own website. Up to 1 point below the claim is amber, more than that is red. Only a direct promise counts (“99%+ purity guaranteed”); explanations of what purity means, one product's figure and page code are not treated as a claim. A certificate that reports only a bound (“>99%”) is judged only when the bound meets the claim, and a specification line is never read as a result.
Whose certificate
A certificate is only read once our client-identity review has looked at it, and one issued to a different company is left out, whether the automatic check or a manual review found it. A certificate issued to the company that runs the supplier's own website counts as the supplier's. A file hosted on another supplier's website is not counted for this one. The same rules decide which certificates appear on supplier and product pages. Only peptide certificates are read: bacteriostatic water, acetic acid and other diluents are left out, and so are product data sheets, which state a specification rather than a batch result.
Main impurity
Shown when the certificate itemises it: a named impurity (TFA, deletion sequence, oxidation…) or the largest secondary peak in the HPLC peak table. Most certificates report only a purity figure, so the rest of the sample is not itemised.
Trust Score
These checks are 10 of the 25 Transparency points: vial content 7 (full credit within ±3%, half up to ±10%, none beyond, over- and underfilled alike), purity 3 (98% is the bar when a supplier advertises no figure). Fewer than 5 readable results gives half credit rather than a guess.
Source and limits
These are the supplier's own published certificates, read automatically from the PDF or image. Janoshik results tables are read twice from the image, cell by cell, and a figure the two readings disagree on is left out rather than guessed. A certificate covers one batch on one date. We have not tested these batches ourselves.

Eros Peptides supplier page and all suppliers on Claims vs COA