Claims vs COA / BulkGLP
BulkGLP: claims vs COA
No site-wide purity promise found on the website. Vial content is still checked against the label.
22
certificates read
15 / 16
vials outside ±3% of label
8
beyond ±10% (major)
—
below advertised purity
| Product | Label → measured | Purity | Main impurity | Lab | COA |
|---|---|---|---|---|---|
| Epitalon 50mg | 50mg → 55.54mg Overfilled +11.1% | 99.61% | 0.39% not itemised | freedom-diagnostics | Open |
| Retatrutide 10mg | 10mg → 12.05mg Overfilled +20.5% | 99.76% | 0.24% not itemised | freedom-diagnostics | Open |
| Retatrutide 10mg | 10mg → 11.2mg Overfilled +12.0% | 99.87% | 0.13% not itemised | freedom-diagnostics | Open |
| Retatrutide 12mg | 12mg → 13.75mg Overfilled +14.6% | 99.5% | 0.50% not itemised | freedom-diagnostics | Open |
| Retatrutide 20mg | 20mg → 22.69mg Overfilled +13.5% | 99.81% | 0.19% not itemised | freedom-diagnostics | Open |
| Semaglutide 20mg | 20mg → 23.6mg Overfilled +18.0% | 99.87% | 0.13% not itemised | freedom-diagnostics | Open |
| Semax 10mg | 10mg → 12.42mg Overfilled +24.2% | 99.83% | 0.17% not itemised | freedom-diagnostics | Open |
| TB-500 10mg | 10mg → 11.05mg Overfilled +10.5% | 99.44% | 0.56% not itemised | freedom-diagnostics | Open |
| Adamax 10mg | 10mg → 10.9mg Over label +9.0% | 99.1% | 0.90% not itemised | freedom-diagnostics | Open |
| MOTS-C 20mg | 20mg → 21.48mg Over label +7.4% | 99.41% | 0.59% not itemised | freedom-diagnostics | Open |
| RETATRUTIDE 50mg | 50mg → 54.13mg Over label +8.3% | 99.87% | 0.13% not itemised | freedom-diagnostics | Open |
| Retatrutide 10mg | 10mg → 10.96mg Over label +9.6% | 99.53% | 0.47% not itemised | freedom-diagnostics | Open |
| Thymalin 10mg | 10mg → 9.53mg Under label -4.7% | 99.55% | 0.45% not itemised | freedom-diagnostics | Open |
| Tirzepatide 40mg | 40mg → 43.6mg Over label +9.0% | 99.84% | 0.16% not itemised | freedom-diagnostics | Open |
| VIP 10mg | 10mg → 9.28mg Under label -7.2% | 99.55% | 0.45% not itemised | freedom-diagnostics | Open |
| GLOW 50mg | Blend, per-component content not listed | 99.09% | 0.91% not itemised | freedom-diagnostics | Open |
| KLOW 80mg | Blend, per-component content not listed | 99.8% | 0.20% not itemised | freedom-diagnostics | Open |
| PT-141 10mg | 10mg → 9.97mg On label -0.3% | 99.71% | 0.29% not itemised | freedom-diagnostics | Open |
| Raw Retatrutide | — → 7.46mg Not checked | 99.96% | 0.04% not itemised | freedom-diagnostics | Open |
| Reconstitution Solution 10ml | Not measured | 99.25% | 0.75% not itemised | freedom-diagnostics | Open |
| Unknown | — → 10.18mg Not checked | 99.951% | 0.05% not itemised | freedom-diagnostics | Open |
| Vitamin B12 10ml | — → 9.92mg Not checked | 99.33% | 0.67% not itemised | freedom-diagnostics | Open |
How this is checked
- Vial content. Measured net peptide content against the size on the label. Within ±3% is on label, 3–10% is off label, beyond ±10% is a major deviation (under- or overfilled). When a certificate weighs several vials of the batch, the vial farthest from the label is the one judged, and with several purity results the lowest counts. Blends are only checked when the certificate lists each component.
- Purity. HPLC purity on each certificate against the purity the supplier promises site-wide on its own website. Up to 1 point below the claim is amber, more than that is red. Only a direct promise counts (“99%+ purity guaranteed”); explanations of what purity means, one product's figure and page code are not treated as a claim. A certificate that reports only a bound (“>99%”) is judged only when the bound meets the claim, and a specification line is never read as a result.
- Whose certificate. A certificate is only read once our client-identity review has looked at it, and one issued to a different company is left out — whether the automatic check or a manual review found it. A certificate issued to the company that runs the supplier's own website counts as the supplier's. A file hosted on another supplier's website is not counted for this one. The same rules decide which certificates appear on supplier and product pages. Only peptide certificates are read: bacteriostatic water, acetic acid and other diluents are left out, and so are product data sheets, which state a specification rather than a batch result.
- Main impurity. Shown when the certificate itemises it: a named impurity (TFA, deletion sequence, oxidation…) or the largest secondary peak in the HPLC peak table. Most certificates report only a purity figure, so the rest of the sample is not itemised.
- Trust Score. These checks are 10 of the 25 Transparency points: vial content 7 (full credit within ±3%, half up to ±10%, none beyond, over- and underfilled alike), purity 3 (98% is the bar when a supplier advertises no figure). Fewer than 5 readable results gives half credit rather than a guess.
- These are the supplier's own published certificates, read automatically from the PDF or image. Janoshik results tables are read twice from the image, cell by cell, and a figure the two readings disagree on is left out rather than guessed. A certificate covers one batch on one date. We have not tested these batches ourselves.