PeptideScanner

Claims vs COA / Biopeptitech

Biopeptitech: claims vs COA

No site-wide purity promise found on the website. Vial content is still checked against the label.
31
certificates read
10 / 14
vials outside ±3% of label
5
beyond ±10% (major)
—
below advertised purity
ProductLabel → measuredPurityMain impurityLabCOA
BPC-157
5mg → 5.71mg
Overfilled +14.2%
99.2%
0.80% not itemisedvanguardOpen
Epitalon
10mg → 8.49mg
Underfilled -15.1%
>99.8%
under 0.20% not itemisedvanguardOpen
IGF1 LR3
1mg → 1.32mg
Overfilled +32.0%
99.61%
0.39% not itemisedvanguardOpen
Melanotan-2
10mg → 7.2mg
Underfilled -28.0%
98.33%
1.67% not itemisedvanguardOpen
Tirzepatide
30mg → 33.26mg
Overfilled +10.9%
99.76%
0.24% not itemisedvanguardOpen
GHK-CU
50mg → 51.6mg
Over label +3.2%
99.47%
0.53% not itemisedvanguardOpen
Glutathione
1500mg → 1560mg
Over label +4.0%
99.08%
0.92% not itemisedvanguardOpen
NAD+
100mg → 104.2mg
Over label +4.2%
99.79%
0.21% not itemisedvanguardOpen
NAD+
500mg → 516.2mg
Over label +3.2%
99.41%
0.59% not itemisedvanguardOpen
Tesamorelin
2mg → 2.1mg
Over label +5.0%
99.1%
0.90% not itemisedvanguardOpen
G6_COAA.pdfNot measured
99.86%
Water Content 10%—Open
AOD-9604Not measured
98.39%
unidentified peak at 5.78 min 1.61%mz-biolabsOpen
CJC-1295 WITH DAC CASNot measured
99.15%
Water Content 8%—Open
CJC-1295/IpamorelinBlend, per-component content not listed——vanguardOpen
GHRP-2
5mg → 5.05mg
On label +1.0%
99.23%
0.77% not itemisedvanguardOpen
GHRP-6
5mg → 4.98mg
On label -0.4%
99.06%
0.94% not itemisedvanguardOpen
Ipamorelin
5mg → 0.46mg
Not checked
99.29%
0.71% not itemisedvanguardOpen
Ipamorelin/TesamorelinBlend, per-component content not listed
99.73%
0.27% not itemisedvanguardOpen
Kisspeptin-10
10mg → 10.08mg
On label +0.8%
99.23%
0.77% not itemisedvanguardOpen
PT-141
10mg → 10.02mg
On label +0.2%
99.62%
0.38% not itemisedvanguardOpen
TB-500
10mg → 0.18mg
Not checked
>99.8%
under 0.20% not itemisedvanguardOpen
TechnologiesNot measured
99.5%
0.50% not itemised—Open
TechnologiesNot measured
99.92%
0.08% not itemised—Open
TechnologiesNot measured
97.1%
2.90% not itemised—Open
TechnologiesNot measured
99.67%
0.33% not itemised—Open
TechnologiesNot measured
99.68%
0.32% not itemised—Open
TechnologiesNot measured
99.94%
0.06% not itemised—Open
TechnologiesNot measured
99.44%
0.56% not itemised—Open
TechnologiesNot measured
99.27%
0.73% not itemised—Open
TechnologiesNot measured
99.76%
0.24% not itemised—Open
TirzepatideNot measured
96.16%
unidentified peak at 7.16 min 3.67%mz-biolabsOpen

How this is checked

  • Vial content. Measured net peptide content against the size on the label. Within ±3% is on label, 3–10% is off label, beyond ±10% is a major deviation (under- or overfilled). When a certificate weighs several vials of the batch, the vial farthest from the label is the one judged, and with several purity results the lowest counts. Blends are only checked when the certificate lists each component.
  • Purity. HPLC purity on each certificate against the purity the supplier promises site-wide on its own website. Up to 1 point below the claim is amber, more than that is red. Only a direct promise counts (“99%+ purity guaranteed”); explanations of what purity means, one product's figure and page code are not treated as a claim. A certificate that reports only a bound (“>99%”) is judged only when the bound meets the claim, and a specification line is never read as a result.
  • Whose certificate. A certificate is only read once our client-identity review has looked at it, and one issued to a different company is left out — whether the automatic check or a manual review found it. A certificate issued to the company that runs the supplier's own website counts as the supplier's. A file hosted on another supplier's website is not counted for this one. The same rules decide which certificates appear on supplier and product pages. Only peptide certificates are read: bacteriostatic water, acetic acid and other diluents are left out, and so are product data sheets, which state a specification rather than a batch result.
  • Main impurity. Shown when the certificate itemises it: a named impurity (TFA, deletion sequence, oxidation…) or the largest secondary peak in the HPLC peak table. Most certificates report only a purity figure, so the rest of the sample is not itemised.
  • Trust Score. These checks are 10 of the 25 Transparency points: vial content 7 (full credit within ±3%, half up to ±10%, none beyond, over- and underfilled alike), purity 3 (98% is the bar when a supplier advertises no figure). Fewer than 5 readable results gives half credit rather than a guess.
  • These are the supplier's own published certificates, read automatically from the PDF or image. Janoshik results tables are read twice from the image, cell by cell, and a figure the two readings disagree on is left out rather than guessed. A certificate covers one batch on one date. We have not tested these batches ourselves.

Biopeptitech supplier page

Peptide Scanner is an independent aggregator. All content is for research purposes only. We do not sell, ship, or endorse any product. Read full disclaimer →