PeptideScanner
Peptide Scanner does not sell peptides. Independent, not affiliated with any supplier. Disclaimer

Atomik Labz: claims vs COA

The purity Atomik Labz advertises and the vial sizes on its labels, checked against the 8 certificates of analysis it publishes.

No site-wide purity promise found on the website. Vial content is still checked against the label.

certificates read
8
vials outside ±3% of label
3 / 4
beyond ±10% (major)
0
below advertised purity
None

On label, within ±3%Off label, 3 to 10%Major, beyond ±10%How this is checked

Atomik Labz certificates: label against measured content and purity
ProductLabel to measuredPurityMain impurityLabCOA
KISSPEPTIN
10mg → 10.51mg
Over label +5.1%
99.88%
0.12% not itemisedils-labsOpen certificate KISSPEPTIN
Tirzepatide
30mg → 28.51mg
Under label -5.0%
99.66%
0.34% not itemisedils-labsOpen certificate Tirzepatide
Tirzepatide
60mg → 62.37mg
Over label +4.0%
99.81%
0.19% not itemisedils-labsOpen certificate Tirzepatide
3MG_TEIPF726_v1_1785263668869-1.pdfNot measured
99.7%
0.30% not itemisedils-labsOpen certificate 3MG_TEIPF726_v1_1785263668869-1.pdf
5mg_CM55626S_v1_1782754510779.pdfNot measured
99.22%
0.78% not itemisedils-labsOpen certificate 5mg_CM55626S_v1_1782754510779.pdf
KPV_-_White_Color_-_KWB6264_v1_1781840049245-1.pdfNot measured
99.53%
0.47% not itemisedils-labsOpen certificate KPV_-_White_Color_-_KWB6264_v1_1781840049245-1.pdf
DSIP
— → 5.54mg
Not checked
99.767%
0.23% not itemisedUnknownOpen certificate DSIP
Tirzepatide
150mg → 150.09mg
On label +0.1%
99.93%
0.07% not itemisedils-labsOpen certificate Tirzepatide

How this is checked

Vial content
Measured net peptide content against the size on the label. Within ±3% is on label, 3 to 10% is off label, beyond ±10% is a major deviation (under- or overfilled). When a certificate weighs several vials of the batch, the vial farthest from the label is the one judged, and with several purity results the lowest counts. Blends are only checked when the certificate lists each component.
Purity
HPLC purity on each certificate against the purity the supplier promises site-wide on its own website. Up to 1 point below the claim is amber, more than that is red. Only a direct promise counts (“99%+ purity guaranteed”); explanations of what purity means, one product's figure and page code are not treated as a claim. A certificate that reports only a bound (“>99%”) is judged only when the bound meets the claim, and a specification line is never read as a result.
Whose certificate
A certificate is only read once our client-identity review has looked at it, and one issued to a different company is left out, whether the automatic check or a manual review found it. A certificate issued to the company that runs the supplier's own website counts as the supplier's. A file hosted on another supplier's website is not counted for this one. The same rules decide which certificates appear on supplier and product pages. Only peptide certificates are read: bacteriostatic water, acetic acid and other diluents are left out, and so are product data sheets, which state a specification rather than a batch result.
Main impurity
Shown when the certificate itemises it: a named impurity (TFA, deletion sequence, oxidation…) or the largest secondary peak in the HPLC peak table. Most certificates report only a purity figure, so the rest of the sample is not itemised.
Trust Score
These checks are 10 of the 25 Transparency points: vial content 7 (full credit within ±3%, half up to ±10%, none beyond, over- and underfilled alike), purity 3 (98% is the bar when a supplier advertises no figure). Fewer than 5 readable results gives half credit rather than a guess.
Source and limits
These are the supplier's own published certificates, read automatically from the PDF or image. Janoshik results tables are read twice from the image, cell by cell, and a figure the two readings disagree on is left out rather than guessed. A certificate covers one batch on one date. We have not tested these batches ourselves.

Atomik Labz supplier page and all suppliers on Claims vs COA