Claims vs COA / Ascend Peptides UK

Ascend Peptides UK: claims vs COA

No site-wide purity promise found on the website. Vial content is still checked against the label.
12
certificates read
9 / 11
vials outside ±3% of label
3
beyond ±10% (major)
—
below advertised purity
ProductLabel → measuredPurityMain impurityLabCOA
CJC-1295 with DAC 10mg
10mg → 11.1mg
Overfilled +11.0%
95.609%
4.39% not itemisedjanoshikOpen
GHK-CU 100mg
100mg → 88.4mg
Underfilled -11.6%
99.195%
0.81% not itemisedjanoshikOpen
TB-500 10mg
10mg → 12.09mg
Overfilled +20.9%
99.944%
0.06% not itemisedjanoshikOpen
Ipamorelin 10mg
10mg → 9.22mg
Under label -7.8%
99.8%
0.20% not itemisedjanoshikOpen
MOTS-C 40mg
40mg → 43.66mg
Over label +9.2%
99.391%
0.61% not itemisedjanoshikOpen
Melanotan 1 10mg
10mg → 9.24mg
Under label -7.6%
99.492%
0.51% not itemisedjanoshikOpen
Melanotan 2 10mg
10mg → 9.02mg
Under label -9.8%
99.561%
0.44% not itemisedjanoshikOpen
Sermorelin 5mg
5mg → 5.22mg
Over label +4.4%
99.305%
0.69% not itemisedjanoshikOpen
Tesamorelin 10mg
10mg → 10.74mg
Over label +7.4%
99.501%
0.50% not itemisedjanoshikOpen
BPC-157 10mg
10mg → 10.11mg
On label +1.1%
99.922%
0.08% not itemisedjanoshikOpen
CJG-1295 without DAC 10mg
10mg → 9.98mg
On label -0.2%
99.525%
0.47% not itemisedjanoshikOpen
IGF-1 LR3 1mg
— → 1.14mg
Not checked
97.756%
2.24% not itemisedjanoshikOpen

How this is checked

  • Vial content. Measured net peptide content against the size on the label. Within ±3% is on label, 3–10% is off label, beyond ±10% is a major deviation (under- or overfilled). When a certificate weighs several vials of the batch, the vial farthest from the label is the one judged, and with several purity results the lowest counts. Blends are only checked when the certificate lists each component.
  • Purity. HPLC purity on each certificate against the purity the supplier promises site-wide on its own website. Up to 1 point below the claim is amber, more than that is red. Only a direct promise counts (“99%+ purity guaranteed”); explanations of what purity means, one product's figure and page code are not treated as a claim. A certificate that reports only a bound (“>99%”) is judged only when the bound meets the claim, and a specification line is never read as a result.
  • Whose certificate. A certificate is only read once our client-identity review has looked at it, and one issued to a different company is left out — whether the automatic check or a manual review found it. A certificate issued to the company that runs the supplier's own website counts as the supplier's. A file hosted on another supplier's website is not counted for this one. The same rules decide which certificates appear on supplier and product pages. Only peptide certificates are read: bacteriostatic water, acetic acid and other diluents are left out, and so are product data sheets, which state a specification rather than a batch result.
  • Main impurity. Shown when the certificate itemises it: a named impurity (TFA, deletion sequence, oxidation…) or the largest secondary peak in the HPLC peak table. Most certificates report only a purity figure, so the rest of the sample is not itemised.
  • Trust Score. These checks are 10 of the 25 Transparency points: vial content 7 (full credit within ±3%, half up to ±10%, none beyond, over- and underfilled alike), purity 3 (98% is the bar when a supplier advertises no figure). Fewer than 5 readable results gives half credit rather than a guess.
  • These are the supplier's own published certificates, read automatically from the PDF or image. Janoshik results tables are read twice from the image, cell by cell, and a figure the two readings disagree on is left out rather than guessed. A certificate covers one batch on one date. We have not tested these batches ourselves.

Ascend Peptides UK supplier page

Peptide Scanner is an independent aggregator. All content is for research purposes only. We do not sell, ship, or endorse any product. Read full disclaimer →