PeptideScanner
Peptide Scanner does not sell peptides. Independent, not affiliated with any supplier. Disclaimer

AminoVault: claims vs COA

The purity AminoVault advertises and the vial sizes on its labels, checked against the 22 certificates of analysis it publishes.

Website claim: 99% purity. …Laboratory Compounds Made in the USA - Verifiable COAs with ≥99% Purity Guarantee Certified GMP - High Purity Guaranteed ISO/IEC 17… Source (read 2026-09-25)

certificates read
22
vials outside ±3% of label
9 / 14
beyond ±10% (major)
0
below advertised purity
5 / 22

On label, within ±3%Off label, 3 to 10%Major, beyond ±10%How this is checked

AminoVault certificates: label against measured content and purity
ProductLabel to measuredPurityMain impurityLabCOA
BPC-157
10mg → 10.56mg
Over label +5.6%
98.8%
0.20 pts below 99%
1.20% not itemisedils-labsOpen certificate BPC-157
Epitalon
10mg → 10.15mg
On label +1.5%
97.67%
1.33 pts below 99%
2.33% not itemisedils-labsOpen certificate Epitalon
Glutathione
1500mg → 1581.15mg
Over label +5.4%
98.89%
0.11 pts below 99%
1.11% not itemisedils-labsOpen certificate Glutathione
Selank
10mg → 10.45mg
Over label +4.5%
98.42%
0.58 pts below 99%
1.58% not itemisedils-labsOpen certificate Selank
COA-251469-QC251062-Klow.pdfBlend, per-component content not listed
98.75%
0.25 pts below 99%
1.25% not itemisedUnknownOpen certificate COA-251469-QC251062-Klow.pdf
CJC-1295 No Dac
10mg → 10.39mg
Over label +3.9%
99.21%
Meets 99%
0.79% not itemisedils-labsOpen certificate CJC-1295 No Dac
Nad+
1000mg → 1048.07mg
Over label +4.8%
99.57%
Meets 99%
0.43% not itemisedils-labsOpen certificate Nad+
SS-31
50mg → 52.02mg
Over label +4.0%
99.63%
Meets 99%
0.37% not itemisedils-labsOpen certificate SS-31
Semaglutide GLP-1
10mg → 10.5mg
Over label +5.0%
99.65%
Meets 99%
0.35% not itemisedils-labsOpen certificate Semaglutide GLP-1
Sermorelin
5mg → 5.25mg
Over label +5.0%
99.62%
Meets 99%
0.38% not itemisedils-labsOpen certificate Sermorelin
Tesamorelin
10mg → 10.33mg
Over label +3.3%
99.89%
Meets 99%
0.11% not itemisedils-labsOpen certificate Tesamorelin
COA-251463-QC250891-TB-500.pdfNot measured
99.9%
Meets 99%
0.10% not itemisedUnknownOpen certificate COA-251463-QC250891-TB-500.pdf
COA-251683-QC250898-Selank-Semax.pdfBlend, per-component content not listed
99.9%
Meets 99%
0.10% not itemisedUnknownOpen certificate COA-251683-QC250898-Selank-Semax.pdf
COA251470-QC251518-KPV.pdfNot measured
99.8%
Meets 99%
0.20% not itemisedUnknownOpen certificate COA251470-QC251518-KPV.pdf
Ara-290
10mg → 10.22mg
On label +2.2%
99.58%
Meets 99%
0.42% not itemisedils-labsOpen certificate Ara-290
BPC-157 / TB-500Blend, per-component content not listed
99.86%
Meets 99%
0.14% not itemisedils-labsOpen certificate BPC-157 / TB-500
GHK-Cu
100mg → 102.66mg
On label +2.7%
99.42%
Meets 99%
0.58% not itemisedils-labsOpen certificate GHK-Cu
IpamorelinNot measured
99.62%
Meets 99%
0.38% not itemisedUnknownOpen certificate Ipamorelin
KLOWBlend, per-component content not listed
99.8%
Meets 99%
0.20% not itemisedils-labsOpen certificate KLOW
MOTS-c
10mg → 10.25mg
On label +2.5%
99.66%
Meets 99%
0.34% not itemisedils-labsOpen certificate MOTS-c
Semax
10mg → 10.26mg
On label +2.6%
99.79%
Meets 99%
0.21% not itemisedils-labsOpen certificate Semax
WolverineBlend, per-component content not listed
99.86%
Meets 99%
0.14% not itemisedils-labsOpen certificate Wolverine

How this is checked

Vial content
Measured net peptide content against the size on the label. Within ±3% is on label, 3 to 10% is off label, beyond ±10% is a major deviation (under- or overfilled). When a certificate weighs several vials of the batch, the vial farthest from the label is the one judged, and with several purity results the lowest counts. Blends are only checked when the certificate lists each component.
Purity
HPLC purity on each certificate against the purity the supplier promises site-wide on its own website. Up to 1 point below the claim is amber, more than that is red. Only a direct promise counts (“99%+ purity guaranteed”); explanations of what purity means, one product's figure and page code are not treated as a claim. A certificate that reports only a bound (“>99%”) is judged only when the bound meets the claim, and a specification line is never read as a result.
Whose certificate
A certificate is only read once our client-identity review has looked at it, and one issued to a different company is left out, whether the automatic check or a manual review found it. A certificate issued to the company that runs the supplier's own website counts as the supplier's. A file hosted on another supplier's website is not counted for this one. The same rules decide which certificates appear on supplier and product pages. Only peptide certificates are read: bacteriostatic water, acetic acid and other diluents are left out, and so are product data sheets, which state a specification rather than a batch result.
Main impurity
Shown when the certificate itemises it: a named impurity (TFA, deletion sequence, oxidation…) or the largest secondary peak in the HPLC peak table. Most certificates report only a purity figure, so the rest of the sample is not itemised.
Trust Score
These checks are 10 of the 25 Transparency points: vial content 7 (full credit within ±3%, half up to ±10%, none beyond, over- and underfilled alike), purity 3 (98% is the bar when a supplier advertises no figure). Fewer than 5 readable results gives half credit rather than a guess.
Source and limits
These are the supplier's own published certificates, read automatically from the PDF or image. Janoshik results tables are read twice from the image, cell by cell, and a figure the two readings disagree on is left out rather than guessed. A certificate covers one batch on one date. We have not tested these batches ourselves.

AminoVault supplier page and all suppliers on Claims vs COA