PeptideScanner

Claims vs COA / Adria Science

Adria Science: claims vs COA

No site-wide purity promise found on the website. Vial content is still checked against the label. The site does mention 99.8% purity for an individual product: “…LYO-0791: match batch 2027602, interpret 10.48 mg content, >99.8% purity and 0.157 EU/mg endotoxins. 14.09.2026 11 min read Endotoxi…” Source (read 2026-09-25)
38
certificates read
30 / 35
vials outside ±3% of label
20
beyond ±10% (major)
—
below advertised purity
ProductLabel → measuredPurityMain impurityLabCOA
AHK-CU 100 mg
100mg → 111.6mg
Overfilled +11.6%
>99.8%
under 0.20% not itemised—Open
AOD-9604 5 mg
5mg → 5.58mg
Overfilled +11.6%
99.2%
0.80% not itemised—Open
BPC-157 10 mg
10mg → 12.45mg
Overfilled +24.5%
99.5%
0.50% not itemised—Open
CJC 1295 with DAC 5 mg
5mg → 4.1mg
Underfilled -18.0%
98.6%
1.40% not itemised—Open
DSIP 10 mg
10mg → 14.13mg
Overfilled +41.3%
99.7%
0.30% not itemised—Open
Epithalon 10 mg
10mg → 8.96mg
Underfilled -10.4%
98.1%
1.90% not itemised—Open
GHK-Cu 100 mg
100mg → 89.4mg
Underfilled -10.6%
>99.8%
under 0.20% not itemised—Open
GHK-Cu 50 mg
50mg → 44.4mg
Underfilled -11.2%
>99.8%
under 0.20% not itemised—Open
HGH Fragment 176-191 10 mg
10mg → 8.45mg
Underfilled -15.5%
99.4%
0.60% not itemised—Open
HGH Fragment 176-191 5 mg
5mg → 4.41mg
Underfilled -11.8%
98.3%
1.70% not itemised—Open
Kisspeptin 10 mg
10mg → 11.44mg
Overfilled +14.4%
>99.8%
under 0.20% not itemised—Open
Melanotan-II 10 mg
10mg → 12.22mg
Overfilled +22.2%
99.6%
0.40% not itemised—Open
NAD+ 500 mg
500mg → 418mg
Underfilled -16.4%
98.9%
1.10% not itemised—Open
PT-141 10 mg
10mg → 13.51mg
Overfilled +35.1%
99.8%
0.20% not itemised—Open
SS-31 10 mg
10mg → 13.13mg
Overfilled +31.3%
99.7%
0.30% not itemised—Open
Selank 10 mg
10mg → 12.13mg
Overfilled +21.3%
>99.8%
under 0.20% not itemised—Open
Semax 10 mg
10mg → 12.46mg
Overfilled +24.6%
99.6%
0.40% not itemised—Open
TB-500 10 mg
10mg → 12.38mg
Overfilled +23.8%
98.6%
1.40% not itemised—Open
TIR10 10 mg
10mg → 8.98mg
Underfilled -10.2%
>99.8%
under 0.20% not itemised—Open
TIR15 15 mg
15mg → 13.41mg
Underfilled -10.6%
99.8%
0.20% not itemised—Open
CJC 1295 no DAC 10 mg
10mg → 10.91mg
Over label +9.1%
99.3%
0.70% not itemised—Open
Cagrilintide 10 mg
10mg → 10.39mg
Over label +3.9%
99.1%
0.90% not itemised—Open
IGF-1lr3 1 mg
1mg → 1.06mg
Over label +6.4%
98.6%
1.40% not itemised—Open
Ipamorelin 10 mg
10mg → 9.13mg
Under label -8.7%
>99.8%
under 0.20% not itemised—Open
KPV 10 mg
10mg → 10.48mg
Over label +4.8%
>99.8%
under 0.20% not itemised—Open
MOTS-C 10 mg
10mg → 10.39mg
Over label +3.9%
99.2%
0.80% not itemised—Open
R20 20 mg
20mg → 18.87mg
Under label -5.7%
99.4%
0.60% not itemised—Open
Sermorelin 10 mg
10mg → 10.5mg
Over label +5.0%
99.7%
0.30% not itemised—Open
TIR30 30 mg
30mg → 31.5mg
Over label +5.0%
99.8%
0.20% not itemised—Open
Tesamorelin 10 mg
10mg → 9.44mg
Under label -5.6%
>99.8%
under 0.20% not itemised—Open
BPC-157/TB-500 20 mgBlend, per-component content not listed
99.6%
0.40% not itemised—Open
CJC-1295 + Ipamorelin 10 mgBlend, per-component content not listed
99.4%
0.60% not itemised—Open
CJC-1295 + Ipamorelin 20 mgBlend, per-component content not listed
99.7%
0.30% not itemised—Open
MOTS-C 40 mg
40mg → 40.5mg
On label +1.3%
99.7%
0.30% not itemised—Open
Melanotan-1 10 mg
10mg → 10mg
On label 0.0%
99.8%
0.20% not itemised—Open
R10 10 mg
10mg → 9.78mg
On label -2.2%
99.4%
0.60% not itemised—Open
R30 30 mg
30mg → 30mg
On label 0.0%
99.8%
0.20% not itemised—Open
Thymosin Alpha-1 10 mg
10mg → 10.3mg
On label +3.0%
99.7%
0.30% not itemised—Open

How this is checked

  • Vial content. Measured net peptide content against the size on the label. Within ±3% is on label, 3–10% is off label, beyond ±10% is a major deviation (under- or overfilled). When a certificate weighs several vials of the batch, the vial farthest from the label is the one judged, and with several purity results the lowest counts. Blends are only checked when the certificate lists each component.
  • Purity. HPLC purity on each certificate against the purity the supplier promises site-wide on its own website. Up to 1 point below the claim is amber, more than that is red. Only a direct promise counts (“99%+ purity guaranteed”); explanations of what purity means, one product's figure and page code are not treated as a claim. A certificate that reports only a bound (“>99%”) is judged only when the bound meets the claim, and a specification line is never read as a result.
  • Whose certificate. A certificate is only read once our client-identity review has looked at it, and one issued to a different company is left out — whether the automatic check or a manual review found it. A certificate issued to the company that runs the supplier's own website counts as the supplier's. A file hosted on another supplier's website is not counted for this one. The same rules decide which certificates appear on supplier and product pages. Only peptide certificates are read: bacteriostatic water, acetic acid and other diluents are left out, and so are product data sheets, which state a specification rather than a batch result.
  • Main impurity. Shown when the certificate itemises it: a named impurity (TFA, deletion sequence, oxidation…) or the largest secondary peak in the HPLC peak table. Most certificates report only a purity figure, so the rest of the sample is not itemised.
  • Trust Score. These checks are 10 of the 25 Transparency points: vial content 7 (full credit within ±3%, half up to ±10%, none beyond, over- and underfilled alike), purity 3 (98% is the bar when a supplier advertises no figure). Fewer than 5 readable results gives half credit rather than a guess.
  • These are the supplier's own published certificates, read automatically from the PDF or image. Janoshik results tables are read twice from the image, cell by cell, and a figure the two readings disagree on is left out rather than guessed. A certificate covers one batch on one date. We have not tested these batches ourselves.

Adria Science supplier page

Peptide Scanner is an independent aggregator. All content is for research purposes only. We do not sell, ship, or endorse any product. Read full disclaimer →