PeptideScanner
Peptide Scanner does not sell peptides. Independent, not affiliated with any supplier. Disclaimer

Accelerate Labs: claims vs COA

The purity Accelerate Labs advertises and the vial sizes on its labels, checked against the 20 certificates of analysis it publishes.

Website claim: 99% purity. …nder controlled quality standards and third-party tested to ≥99% purity to support lot-to-lot consistency and reproducible analytic… Source (read 2026-09-25)

certificates read
20
vials outside ±3% of label
7 / 9
beyond ±10% (major)
6
below advertised purity
6 / 20

On label, within ±3%Off label, 3 to 10%Major, beyond ±10%How this is checked

Accelerate Labs certificates: label against measured content and purity
ProductLabel to measuredPurityMain impurityLabCOA
BPC-157 5mg
5mg → 6.08mg
Overfilled +21.6%
97.23%
1.77 pts below 99%
2.77% not itemisedfreedom-diagnosticsOpen certificate BPC-157 5mg
KPV Smg
5mg → 4.78mg
Under label -4.4%
93.55%
5.45 pts below 99%
6.45% not itemisedfreedom-diagnosticsOpen certificate KPV Smg
ARA-290Not measured
92.82%
6.18 pts below 99%
7.18% not itemisedmz-biolabsOpen certificate ARA-290
LL-37Not measured
96.54%
2.46 pts below 99%
unidentified peak at 4.08 min 0.3%mz-biolabsOpen certificate LL-37
MOTS-C 10mg
10mg → 12.27mg
Overfilled +22.7%
99.45%
Meets 99%
0.55% not itemisedfreedom-diagnosticsOpen certificate MOTS-C 10mg
NAD+
500mg → 512mg
On label +2.4%
96.51%
2.49 pts below 99%
3.49% not itemisedvanguardOpen certificate NAD+
PT 141 10mg
10mg → 12.97mg
Overfilled +29.7%
99.83%
Meets 99%
0.17% not itemisedfreedom-diagnosticsOpen certificate PT 141 10mg
Retatrutide 10mg
10mg → 11.63mg
Overfilled +16.3%
99.82%
Meets 99%
0.18% not itemisedfreedom-diagnosticsOpen certificate Retatrutide 10mg
Semaglutide 10mg
10mg → 12.73mg
Overfilled +27.3%
99.85%
Meets 99%
0.15% not itemisedfreedom-diagnosticsOpen certificate Semaglutide 10mg
Tirzepatide
10mg → 11.11mg
Overfilled +11.1%
99.71%
Meets 99%
0.29% not itemisedvanguardOpen certificate Tirzepatide
MGFNot measured
98.87%
0.13 pts below 99%
1.13% not itemisedmz-biolabsOpen certificate MGF
CJC-1295 no DACNot measured
99.68%
Meets 99%
unidentified peak at 5.09 min 0.05%mz-biolabsOpen certificate CJC-1295 no DAC
GHK-Cu 50mgNot measured
99.64%
Meets 99%
0.36% not itemisedfreedom-diagnosticsOpen certificate GHK-Cu 50mg
GLOW 70mgBlend, per-component content not listed
99.76%
Meets 99%
0.24% not itemisedfreedom-diagnosticsOpen certificate GLOW 70mg
GlutathioneNot measured
99.12%
Meets 99%
0.88% not itemisedmz-biolabsOpen certificate Glutathione
IpamorelinNot measured
99.53%
Meets 99%
0.47% not itemisedmz-biolabsOpen certificate Ipamorelin
SelankNot measured
>99.8%
Meets 99%
under 0.20% not itemisedvanguardOpen certificate Selank
SemaglutideNot measured
99.97%
Meets 99%
0.03% not itemisedmz-biolabsOpen certificate Semaglutide
TB-500Not measured
99.5%
Meets 99%
unidentified peak at 452 min 0.44%mz-biolabsOpen certificate TB-500
Tesamorelin
5mg → 4.96mg
On label -0.8%
99.36%
Meets 99%
0.64% not itemisedvanguardOpen certificate Tesamorelin

How this is checked

Vial content
Measured net peptide content against the size on the label. Within ±3% is on label, 3 to 10% is off label, beyond ±10% is a major deviation (under- or overfilled). When a certificate weighs several vials of the batch, the vial farthest from the label is the one judged, and with several purity results the lowest counts. Blends are only checked when the certificate lists each component.
Purity
HPLC purity on each certificate against the purity the supplier promises site-wide on its own website. Up to 1 point below the claim is amber, more than that is red. Only a direct promise counts (“99%+ purity guaranteed”); explanations of what purity means, one product's figure and page code are not treated as a claim. A certificate that reports only a bound (“>99%”) is judged only when the bound meets the claim, and a specification line is never read as a result.
Whose certificate
A certificate is only read once our client-identity review has looked at it, and one issued to a different company is left out, whether the automatic check or a manual review found it. A certificate issued to the company that runs the supplier's own website counts as the supplier's. A file hosted on another supplier's website is not counted for this one. The same rules decide which certificates appear on supplier and product pages. Only peptide certificates are read: bacteriostatic water, acetic acid and other diluents are left out, and so are product data sheets, which state a specification rather than a batch result.
Main impurity
Shown when the certificate itemises it: a named impurity (TFA, deletion sequence, oxidation…) or the largest secondary peak in the HPLC peak table. Most certificates report only a purity figure, so the rest of the sample is not itemised.
Trust Score
These checks are 10 of the 25 Transparency points: vial content 7 (full credit within ±3%, half up to ±10%, none beyond, over- and underfilled alike), purity 3 (98% is the bar when a supplier advertises no figure). Fewer than 5 readable results gives half credit rather than a guess.
Source and limits
These are the supplier's own published certificates, read automatically from the PDF or image. Janoshik results tables are read twice from the image, cell by cell, and a figure the two readings disagree on is left out rather than guessed. A certificate covers one batch on one date. We have not tested these batches ourselves.

Accelerate Labs supplier page and all suppliers on Claims vs COA